ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
97
|
Sat Nov 22 16:53:39 2014 |
Axel König | Infineon | Infineon old | Infineon_old_run001 | 55000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:97mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000992
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
98
|
Sat Nov 22 17:00:43 2014 |
Axel König | Infineon | Infineon old | damaged strixel sensors, strange IV behaviour | | | | Unknown |
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). |
99
|
Sat Nov 22 18:08:03 2014 |
Axel König | Infineon | hardware run | Infineon_old_run002 | 55000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:102mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000993
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
100
|
Sat Nov 22 19:29:40 2014 |
Axel König | AIDA | DUT Position | | | | | Unknown |
|
101
|
Sun Nov 23 00:20:41 2014 |
Axel König | Infineon | hardware run | Infineon_old_run003 | 30000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:?, H:?
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000994
DaqEvents: 30000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
102
|
Sun Nov 23 00:24:15 2014 |
Axel König | Infineon | hardware run | Infineon_old_run004 | 168725 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.6529uA
(new table calibration): V:81, H:88
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000996
DaqEvents: 168725 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
103
|
Sun Nov 23 00:51:07 2014 |
Axel König | Infineon | hardware run | Infineon_old_run005 | 26569 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4609uA
(new table calibration): V:75, H:94.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000997
DaqEvents: 26569 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset)
|
|
107
|
Sun Nov 23 09:32:48 2014 |
Axel König | Infineon | hardware run | Infineon_old_run007 | 63913 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:96.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000999
DaqEvents: 63913 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
108
|
Sun Nov 23 09:36:27 2014 |
Axel König | Infineon | hardware run | Infineon_old_run006 | 526562 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:95
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000998
DaqEvents: 526562 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
109
|
Sun Nov 23 09:49:00 2014 |
Markus Friedl | Belle SVD | cooling | | | | | Unknown |
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
|
110
|
Sun Nov 23 10:32:41 2014 |
Hao Yin | Belle SVD | PedestalRun | 016 | 10000 | | | Unknown |
Pedestal Run
room temperature (30C)
Bias scans planned |
111
|
Sun Nov 23 10:51:49 2014 |
Hao Yin | Belle SVD | HardwareRun | 042 | 76863 | | | Unknown |
Hardware Run +-40V Bias
Room Temperature
Pedestal 016
Zero Suppressed |
112
|
Sun Nov 23 12:17:59 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 044 | 20000 | | | Unknown |
Hardware Run +-30V Bias
Room Temperature
Pedestal 017 (again marked all the bad strips)
Zero Suppressed |
113
|
Sun Nov 23 12:39:45 2014 |
Axel König | common | PMT's of EUDET (Igor Rubinsky) | | | | | Unknown |
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen). |
114
|
Sun Nov 23 12:55:47 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 045 | 20000 | | | Unknown |
Hardware Run +-50V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
Zero Suppressed |
115
|
Sun Nov 23 15:07:54 2014 |
Markus Friedl | Belle SVD | common | | | | | Unknown |
Geometry setup of FW/BW:
(all dimensions are in mm and refer to the sensor planes) |
116
|
Sun Nov 23 15:09:53 2014 |
Markus Friedl | Belle SVD | PedestalRun | 001 | 10000 | | | Good |
Initial pedestal run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side) |
117
|
Sun Nov 23 15:10:42 2014 |
Markus Friedl | Belle SVD | CalibrationRun | 001 | 83400 | | | Good |
Initial calibration run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side) |