  118   Sun Nov 23 15:13:37 2014 Markus FriedlBelle SVDHardwareRun00310060023.11.2014 14:07:2323.11.2014 16:51:27Good

Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry is currently edited by Thomas Bergauer on 193.170.243.91    120   Sun Nov 23 17:51:44 2014 Benedikt WürknerBelle SVDHardwareRun04610000020:0620:36Unknown

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

  106   Sun Nov 23 01:37:42 2014 Hao YinBelle SVDHardwareRun040200002014-11-23 01:37:00 Unknown

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

  94   Sat Nov 22 15:31:49 2014 Hao YinBelle SVDHardwareRun038437882014-11-22 15:18:40 Unknown

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

  105   Sun Nov 23 01:05:43 2014 Hao YinBelle SVDHardwareRun039200002014-11-22 15:18:40 Crap

Cooled down to -20

Bias voltage set to +-80V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

 

  73   Fri Nov 21 15:07:24 2014 Benedikt WürknerBelle SVDHardwareRun0191509482014-11-21 02:41:552014-11-21 10:11:02Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

  1   Fri Nov 14 19:01:27 2014 Thomas BergauercommonAdministrative Procedures for Departure    Unknown

Wednesday:

* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt werden, was in der Zone war (also nicht im Counting room)

Merchandise-Bestätigung für die Anreise ist im attachment!

 

Anreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5855845

Abreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5863835

  2   Fri Nov 14 19:22:40 2014 Martin Kurzcommonip addresses, portforwarding, wlan    Unknown

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.61.16 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.10 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 AIDA DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22)  SSH(9004)
192.168.0.15 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
       

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

  3   Fri Nov 14 19:47:25 2014 Thomas Bergauer Telefonnummern    Unknown

* CCC (zentraler Beschleuniger-Kontrollraum): 77500

* H6A Controlroom: 76755

* HEPHY-Handy: 16-2471 or +41 76 487 2471 from outside of CERN

* Office in Meyrin: 12-R11: 74592

 

Hostel-Zimmern:

* Bergi: 79326

* Benni: 60232

* Hao: 70408

 

Andere Wichtige Leute:

* Beam-Dame: Edda Gschwendner 16-5080

* NA Hallen Verantwortlicher: Michael Jeckel

Lookup Telefonnummern: http://phonebook.cern.ch

 
  4   Fri Nov 14 19:49:04 2014 Florian BuchsteinercommonBelle Setup    Unknown
  5   Fri Nov 14 19:52:12 2014 Thomas Bergauer important web pages    Unknown

SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

general Information about the Beam line(s): http://sba.web.cern.ch/sba/

  6   Sat Nov 15 11:36:41 2014 Thomas BergauercommonChecklist for North Area access    Unknown

 

Checklist for North Area access: 

  • Dosimeter (http://dosimetry.web.cern.ch/en)
  • Helmet and safety shoes (http://gs-dep.web.cern.ch/en/content/stores_hours)
  • Access right to H6A control room (request via EDH): Control Room HNA-447 (0887-1-Q45). Activate access right on your CERN access card at one of the validation stations (https://espace.cern.ch/service-access-control/default.aspx)
  • For using CERN rental car, request "CERN vehicle driving license (V)" via EDH
  • Park in front of bldg. 890. Walk to North Hall (bldg. 887) through bldg. 907. Swipe dosimeter in front of electronic lock next to the entrance door. Turn left inside bldg. 887. Control room Q45 is on the left-hand side of the upper level. Swipe CERN access card in front of electronic lock.
  7   Sat Nov 15 11:37:19 2014 Thomas BergauerAIDAList of EUDET Telescope PCs in H6b    Unknown

 https://twiki.cern.ch/twiki/bin/view/CLIC/ClicPixelDataTakingCERNPS2014

  8   Sat Nov 15 12:41:50 2014 Benedikt WürknerBelle SVDDiscoveries during preliminary sensor tests    Unknown

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

  9   Sun Nov 16 14:22:51 2014 Thomas BergauerAIDAPC Configuration EUDET Telescope in H6b    Unknown

PC (gehört AIDA) in H6b control room:  ssh telescope@pcaidatb.cern.ch

 

 

  10   Sun Nov 16 21:37:56 2014 Hao YincommonAIM    Unknown

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

  11   Mon Nov 17 19:23:57 2014 Thomas BergauerInfineonPI XY table initial position    Unknown

initial position of Infineon Stack (PI Micromove):
(guess center position by eye)

STRIPS IN HORIZONTAL DIRECTION

* vertical axis: M511.DD: Zero position 81.0mm / higher values correspond to lowering the table

* vertical axis: M521.DD: Zero position 96.0mm / higher values correspond to move the table to the table mounting

  12   Mon Nov 17 22:03:02 2014 Martin KurzcommonDrucker    Unknown

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

  28   Tue Nov 18 12:35:32 2014 Axel KönigcommonInfineon (4 modules) TLU Settings    Unknown
  1.  VNC to 192.168.0.18
  2. In command line: cd C:\Users\telescope\eudaq\bin
  3. TLUControl.exe.exe -d 2 -a 11 - i RJ45

Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45

Dut Position (left to right):  11, 06, 05, 07