| ID | 
Date  | 
Author | 
Project | 
Subject | 
Run Number | 
Events | 
StartTime | 
EndTime | 
Data | 
| 
  39  
 | 
Wed Nov 19 16:24:25 2014 | 
Axel König | common | Running EUDAQ |   |   |   |   | Unknown | 
Windows PC at Telescope: 
0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start 
1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's 
2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat 
3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.) 
4.) configure 
5.) start 
x) Online monitor in preparation 
Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC]  | 
| 
  38  
 | 
Wed Nov 19 09:26:39 2014 | 
Axel König | Infineon | hardware run | Infineon_run006 | 1500 |   |   | Unknown | 
Infineon new stack - batch 4 
multi hit 
  
HV=300V, total I = 4.0200 µA 
  
strips vertical 
  
Table Position: H: 96mm V: 91mm 
  
data file in L:\cern14\infineon\Infineon Run vert 
  
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg 
  
-- stopped -- 
1500 Events only --> no trigger signals from TU (01:30 Uhr)  | 
| 
  37  
 | 
Wed Nov 19 00:58:27 2014 | 
Axel König | Infineon | hardware run | Infineon_run005 | 87000 |   |   | Unknown | 
Infineon new stack - batch 4  
multi hit 
  
HV=300V, total I = 4.0200 µA 
  
strips vertical 
  
Table Position: H: 96mm V: 81mm 
  
data file in L:\cern14\infineon\Infineon Run vert 
  
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg 
  
--stopped 19.11 // 01:00 -- 
Reason: Enough events, new dut postion for next multi run 
Events: 87000  | 
| 
  36  
 | 
Tue Nov 18 23:04:34 2014 | 
Axel König | Infineon | hardware run | Infineon_run004 | 400000 |   |   | Unknown | 
Infineon new stack - batch 4  
single hit 
  
HV=300V, total I = 4.0044 µA 
  
strips vertical 
  
Table Position: H: 96mm V: 81mm 
  
data file in L:\cern14\infineon\Infineon Run vert 
  
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg 
  
--stopped 18.11 // 23:05--- 
Reason: Enough events, next run with the same position but now multi six 
Events: 400000 
   | 
| 
  35  
 | 
Tue Nov 18 20:42:18 2014 | 
Benedikt Würkner | Belle SVD | Coordinates of the DUT |   |   |   |   | Unknown | 
We set the coordinates trying to put the beam in an area with well working APVs 
Peak of course differs for n and p sensors due to their different pitch. 
L4-6 n-side Peak around strip 180 
L4&6 p-side mean value around strip 380 
L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320 
The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.   | 
| 
  33  
 | 
Tue Nov 18 20:26:12 2014 | 
Hao Yin | Belle SVD | HardwareRun_001 |   |   | Tue Nov 18 18:21:50 CET 2014 |   | Unknown | 
At room temperature 
Latest ADC scan and FIR run. 
Latest CAL. 
  
Position: 0.0, see elog entry.  | 
| 
  32  
 | 
Tue Nov 18 18:45:01 2014 | 
Hao Yin | Belle SVD | Trigger Delay scan |   |   | Tue Nov 18 18:21:50 CET 2014 |   | Unknown | 
At room temperature 
First run was at: 23 (no track) 
  
TimingRun_001: 
Trigger delay: 26 
 
  
TimingRun_002: 
Trigger delay: 29 
  
TimingRun_003: 
Trigger delay: 32 
 
 
  
TimingRun_004: 
Trigger delay: 20 
  
  
TimingRun_005: 
Trigger delay: 17 
 
  
 TimingRun_005: 
Trigger delay: 14 
Trigger chip delay: 110 
 
  
   | 
| 
  31  
 | 
Tue Nov 18 18:33:31 2014 | 
Axel König | Infineon | hardware run | Infineon_run003 | 300000 |   |   | Unknown | 
Infineon new stack - batch 4 
single hit 
HV=300V, total I = 4.0044 µA 
strips vertical 
Table Position: H: 96mm V: 101mm 
data file in L:\cern14\infineon\Infineon Run vert 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg 
  
--Stopped 18.11 / 20:20--- 
Reason: Enough events, adjusting new DUT position for next run 
Events: 300000  | 
| 
  30  
 | 
Tue Nov 18 18:29:55 2014 | 
Axel König | Infineon | calibration run | Infineon_run002 |   |   |   | Unknown | 
Infineon_run002 is just a calibration run for the vertical positioned sensors.  
data file in L:\cern14\infineon\Infineon Run vert 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg  | 
| 
  29  
 | 
Tue Nov 18 13:13:53 2014 | 
Thomas Bergauer | Infineon | hardware run | infineon_run001 | 225508 |   |   | Unknown | 
Infineon new stack - batch 4 
single hit 
  
HV=300V, total I = 4.2475 µA 
  
strips horizontal 
  
data file in L:\cern14\infineon\Infineon Run horiz 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg 
  
  
STOPPED by main User in H6B (18:11, 15:00) 
  
Events: 225508 
Next step: rearange modules vertically 
   | 
| 
  28  
 | 
Tue Nov 18 12:35:32 2014 | 
Axel König | common | Infineon (4 modules) TLU Settings |   |   |   |   | Unknown | 
    -  VNC to 192.168.0.18
 
    - In command line: cd C:\Users\telescope\eudaq\bin
 
    - TLUControl.exe.exe -d 2 -a 11 - i RJ45
 
 
Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45 
Dut Position (left to right):  11, 06, 05, 07  | 
| 
  27  
 | 
Tue Nov 18 10:26:56 2014 | 
Hao Yin | Belle SVD | CalibrationRun_003 |   |   | Tue Nov 18 10:26:52 CET 2014 |   | Unknown | 
At room temperature 
Latest delay and FIRRun   | 
| 
  26  
 | 
Tue Nov 18 10:12:25 2014 | 
Hao Yin | Belle SVD | 6let PedestalRun_005 |   | 10000 | Tue Nov 18 10:11:45 CET 2014 |   | Unknown | 
At room temperature 
Latest delay, FIRRun002.  
Check for bad strips.  | 
| 
  25  
 | 
Tue Nov 18 09:51:11 2014 | 
Hao Yin |   | CalibrationRun_002 |   |   | Tue Nov 18 09:50:24 CET 2014 |   | Unknown | 
At room temperature 
PedestalRun004  
Latest delay settings and FIRRun  | 
| 
  24  
 | 
Tue Nov 18 09:48:53 2014 | 
Hao Yin | Belle SVD | PedestalRun_004 |   | 10000 | Tue Nov 18 09:48:30 CET 2014 |   | Unknown | 
At room temperature. 
Old delay settings and FIRRun_002 
   | 
| 
  23  
 | 
Tue Nov 18 09:45:59 2014 | 
Hao Yin |   | FIRRun_002 | 002 |   | Tue Nov 18 09:45:58 CET 2014 |   | Unknown | 
New FIR run after reconecting to original setting.   | 
| 
  22  
 | 
Tue Nov 18 01:05:04 2014 | 
Hao Yin | Belle SVD | PedestalRun_003 |   |   | Tue Nov 18 01:03:32 CET 2014 |   | Unknown | 
New pedestal run after switching the connectors. 
At room temperature   | 
| 
  21  
 | 
Tue Nov 18 01:03:18 2014 | 
Hao Yin | Belle SVD | Remapped FADC inputs |   |   | Tue Nov 18 01:03:32 CET 2014 |   | Unknown | 
We moved the second cable to the third connector on the FADC to match DESY testbeam conditions.   | 
| 
  20  
 | 
Mon Nov 17 23:04:57 2014 | 
Hao Yin | Belle SVD | PedestalRun_002 |   | 10338 | Mon Nov 17 23:03:03 CET 2014 |   | Unknown | 
Pedestal run at room temperature. 
6 subevents. Noise reference run. 
Delay as latest run. 
  
Reference run for bad strips.  | 
| 
  19  
 | 
Mon Nov 17 22:28:09 2014 | 
Hao Yin |   | CalibrationRun | 001 |   | Mon Nov 17 22:27:07 CET 2014 |   | Unknown | 
Noise file from run 001  
PedestalRun_001 
FIRRun_001 
At room temperature 
See DelayRun_001 
   |