Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 4 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sun Nov 16 21:37:56 2014, Hao Yin, common, AIM, , , , , Unknown 

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

Entry  Mon Nov 17 19:23:57 2014, Thomas Bergauer, Infineon, PI XY table initial position, , , , , Unknown 

initial position of Infineon Stack (PI Micromove):
(guess center position by eye)

STRIPS IN HORIZONTAL DIRECTION

* vertical axis: M511.DD: Zero position 81.0mm / higher values correspond to lowering the table

* vertical axis: M521.DD: Zero position 96.0mm / higher values correspond to move the table to the table mounting

Entry  Mon Nov 17 22:03:02 2014, Martin Kurz, common, Drucker, , , , , Unknown 

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

Entry  Mon Nov 17 22:18:27 2014, Hao Yin, Belle SVD, ADC delay scan, , , Mon Nov 17 22:08:29, , Unknown 

L3-p: 18

L4-p: 36

L5-p: 33

L6-p: 39

 

L3-n: 18

L4-n: 36

L5-n: 36

L6-n: 35

Entry  Mon Nov 17 22:21:41 2014, Hao Yin, , FIR run, 001, , Mon Nov 17 22:08:29 CET 2014, , Good 

Excellent, brilliant run. 

Entry  Mon Nov 17 22:21:50 2014, Hao Yin, , Bad APVs, , , Mon Nov 17 22:08:29 CET 2014, , Unknown 

List with bad APVs:


 

Crap:

 APV 5 L6-p Channel 23

 

Not working:

 L3-n APV 3

 

Entry  Mon Nov 17 22:28:05 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Mon Nov 17 22:28:07 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Mon Nov 17 22:28:09 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Tue Nov 18 01:03:18 2014, Hao Yin, Belle SVD, Remapped FADC inputs, , , Tue Nov 18 01:03:32 CET 2014, , Unknown 

We moved the second cable to the third connector on the FADC to match DESY testbeam conditions. 

Entry  Tue Nov 18 01:05:04 2014, Hao Yin, Belle SVD, PedestalRun_003, , , Tue Nov 18 01:03:32 CET 2014, , Unknown 

New pedestal run after switching the connectors.

At room temperature 

Entry  Tue Nov 18 09:45:59 2014, Hao Yin, , FIRRun_002, 002, , Tue Nov 18 09:45:58 CET 2014, , Unknown 

New FIR run after reconecting to original setting. 

Entry  Tue Nov 18 09:51:11 2014, Hao Yin, , CalibrationRun_002, , , Tue Nov 18 09:50:24 CET 2014, , Unknown 

At room temperature

PedestalRun004 

Latest delay settings and FIRRun

Entry  Tue Nov 18 10:26:56 2014, Hao Yin, Belle SVD, CalibrationRun_003, , , Tue Nov 18 10:26:52 CET 2014, , Unknown 

At room temperature

Latest delay and FIRRun 

Entry  Tue Nov 18 12:35:32 2014, Axel König, common, Infineon (4 modules) TLU Settings, , , , , Unknown 
  1.  VNC to 192.168.0.18
  2. In command line: cd C:\Users\telescope\eudaq\bin
  3. TLUControl.exe.exe -d 2 -a 11 - i RJ45

Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45

Dut Position (left to right):  11, 06, 05, 07

Entry  Tue Nov 18 18:29:55 2014, Axel König, Infineon, calibration run, Infineon_run002, , , , Unknown 

Infineon_run002 is just a calibration run for the vertical positioned sensors. 

data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
Entry  Tue Nov 18 18:45:01 2014, Hao Yin, Belle SVD, Trigger Delay scan, , , Tue Nov 18 18:21:50 CET 2014, , Unknown 

At room temperature

First run was at: 23 (no track)

 

TimingRun_001:

Trigger delay: 26

 

TimingRun_002:

Trigger delay: 29

 

TimingRun_003:

Trigger delay: 32


 

TimingRun_004:

Trigger delay: 20

 
 

TimingRun_005:

Trigger delay: 17

 

TimingRun_005:

Trigger delay: 14
Trigger chip delay: 110

 

 

 

Entry  Tue Nov 18 20:26:12 2014, Hao Yin, Belle SVD, HardwareRun_001, , , Tue Nov 18 18:21:50 CET 2014, , Unknown 

At room temperature

Latest ADC scan and FIR run.

Latest CAL.

 

Position: 0.0, see elog entry.

Entry  Tue Nov 18 20:42:18 2014, Benedikt Würkner, Belle SVD, Coordinates of the DUT, , , , , Unknown 

We set the coordinates trying to put the beam in an area with well working APVs

Peak of course differs for n and p sensors due to their different pitch.

L4-6 n-side Peak around strip 180

L4&6 p-side mean value around strip 380

L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320

The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.

Entry  Wed Nov 19 16:24:25 2014, Axel König, common, Running EUDAQ, , , , , Unknown 

Windows PC at Telescope:

0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start

1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's

2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat

3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.)

4.) configure

5.) start

x) Online monitor in preparation

Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC]

ELOG V3.1.5-fc6679b