Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 3 of 6  Not logged in ELOG logo
Entry  Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

Entry  Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

Entry  Sat Nov 15 12:41:50 2014, Benedikt Würkner, Belle SVD, Discoveries during preliminary sensor tests, , , , , Unknown weird_signal.pngfaulty-signal-l4_n.pngfaulty-signal_l4_n_2.png

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Entry  Tue Nov 18 20:42:18 2014, Benedikt Würkner, Belle SVD, Coordinates of the DUT, , , , , Unknown 

We set the coordinates trying to put the beam in an area with well working APVs

Peak of course differs for n and p sensors due to their different pitch.

L4-6 n-side Peak around strip 180

L4&6 p-side mean value around strip 380

L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320

The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.

Entry  Thu Nov 20 10:33:13 2014, Benedikt Würkner, Belle SVD, FIRRun and Delay Scan, 003, , , , Unknown Temp_19-11-14.PNG

 Cooled see appendix

with new layout (l3_n-side channels changed and reactivated).

Latest FIRRun

Entry  Thu Nov 20 10:39:11 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:39:13 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:41:54 2014, Benedikt Würkner, Belle SVD, CalibrationRun_005, , , , , Unknown 

 cooled see appendix (FIRRun_003)

PedestalRun_009

Entry  Thu Nov 20 11:14:19 2014, Benedikt Würkner, , HardwareRun_009, 009, , , , Crap 

 cooling see attachment of FIRRun003

Ped 009

Cal 005

Multi 6 raw mode

L5_n_side out of order

 

FIFO_FULL_ERROR starting at ~2000 events

Entry  Fri Nov 21 15:02:28 2014, Benedikt Würkner, Belle SVD, HardwareRun, 013, 1433, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 15:03:08 2014, Benedikt Würkner, Belle SVD, HardwareRun, 014, 989, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 15:07:24 2014, Benedikt Würkner, Belle SVD, HardwareRun, 019, 150948, 2014-11-21 02:41:55, 2014-11-21 10:11:02, Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

Entry  Fri Nov 21 15:10:19 2014, Benedikt Würkner, , HardwareRun, 15-22 (exept 19) , none, , , Crap 
 
Entry  Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown SPS_Testbeam-Temp.xlsxScreen_Shot_2014-11-22_at_12.41.44.png

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Entry  Sun Nov 23 12:17:59 2014, Benedikt Würkner, Belle SVD, HardwareRun, 044, 20000, , , Unknown 

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

Entry  Sun Nov 23 12:55:47 2014, Benedikt Würkner, Belle SVD, HardwareRun, 045, 20000, , , Unknown 

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

Entry is currently edited by Thomas Bergauer on 193.170.243.91  Entry  Sun Nov 23 17:51:44 2014, Benedikt Würkner, Belle SVD, HardwareRun, 046, 100000, 20:06, 20:36, Unknown 

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

Entry  Fri Nov 14 19:49:04 2014, Florian Buchsteiner, common, Belle Setup, , , , , Unknown SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
 
Entry  Sun Nov 16 21:37:56 2014, Hao Yin, common, AIM, , , , , Unknown 

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi