ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
29
|
Tue Nov 18 13:13:53 2014 |
Thomas Bergauer | Infineon | hardware run | infineon_run001 | 225508 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.2475 µA
strips horizontal
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
STOPPED by main User in H6B (18:11, 15:00)
Events: 225508
Next step: rearange modules vertically
|
30
|
Tue Nov 18 18:29:55 2014 |
Axel König | Infineon | calibration run | Infineon_run002 | | | | Unknown |
Infineon_run002 is just a calibration run for the vertical positioned sensors.
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg |
31
|
Tue Nov 18 18:33:31 2014 |
Axel König | Infineon | hardware run | Infineon_run003 | 300000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 101mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--Stopped 18.11 / 20:20---
Reason: Enough events, adjusting new DUT position for next run
Events: 300000 |
35
|
Tue Nov 18 20:42:18 2014 |
Benedikt Würkner | Belle SVD | Coordinates of the DUT | | | | | Unknown |
We set the coordinates trying to put the beam in an area with well working APVs
Peak of course differs for n and p sensors due to their different pitch.
L4-6 n-side Peak around strip 180
L4&6 p-side mean value around strip 380
L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320
The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data. |
36
|
Tue Nov 18 23:04:34 2014 |
Axel König | Infineon | hardware run | Infineon_run004 | 400000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
|
37
|
Wed Nov 19 00:58:27 2014 |
Axel König | Infineon | hardware run | Infineon_run005 | 87000 | | | Unknown |
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000 |
38
|
Wed Nov 19 09:26:39 2014 |
Axel König | Infineon | hardware run | Infineon_run006 | 1500 | | | Unknown |
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 91mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr) |
39
|
Wed Nov 19 16:24:25 2014 |
Axel König | common | Running EUDAQ | | | | | Unknown |
Windows PC at Telescope:
0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start
1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's
2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat
3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.)
4.) configure
5.) start
x) Online monitor in preparation
Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC] |
40
|
Wed Nov 19 18:20:29 2014 |
Axel König | Infineon | calibration run | Infineon_run007_cal | | | | Unknown |
|
42
|
Wed Nov 19 20:04:53 2014 |
Hao Yin | Belle SVD | PedestalRun_006 | | | | | Unknown |
Temperature: See attachment
FIRFilterRun_002
Layer 3-n side deactivated, because Hao broke it. |
43
|
Wed Nov 19 20:07:05 2014 |
Hao Yin | Belle SVD | HardwareRun_002 | | | | | Unknown |
Multi-6 cooled.
See latest Noise, and PedestalRun.
|
44
|
Wed Nov 19 21:56:44 2014 |
Axel König | Infineon | hardware run | Infineon_run008 | 244167 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0758 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167 |
45
|
Wed Nov 19 22:15:41 2014 |
Axel König | Infineon | hardware run | Infineon_run010 | 1498709 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
EUDAQ data: Run951 and Run952
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped 20.11 / 09:35--
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) |
46
|
Wed Nov 19 22:25:29 2014 |
Hao Yin | Belle SVD | PedestalRun_008 [CheckLayout] | | | | | Unknown |
cooled (temperature see attachment latest noise run),
latest Noise, FIR settings with the right layout mapping. |
47
|
Wed Nov 19 22:59:24 2014 |
Hao Yin | Belle SVD | CalibrationRun_004 | | | | | Crap |
cooled (see last calibration run)
Latest noise, FIRfilter settings.
Failed due to VME read timeout. |
48
|
Wed Nov 19 23:15:50 2014 |
Hao Yin | Belle SVD | HardwareRun_003 | | | | | Unknown |
cooled, latest noise, cal, PedestalRun.
Rawmode |
49
|
Wed Nov 19 23:31:08 2014 |
Hao Yin | Belle SVD | HardwareRun_004 | | | | | Unknown |
Same as HardwareRun_003 but with ZS. |
50
|
Thu Nov 20 00:52:50 2014 |
Hao Yin | Belle SVD | FIRRun_002 | | | | | Unknown |
cooled with new delay run |
51
|
Thu Nov 20 00:54:21 2014 |
Hao Yin | Belle SVD | PedestalRun_008 | | | | | Unknown |
temp see attachment (von flo)
10000
latest fir filter (002) |
52
|
Thu Nov 20 00:55:14 2014 |
Hao Yin | Belle SVD | HardwareRun_007 | | | | | Unknown |
temp cooled see attachment
last noise run(007)
FIRRun_002
PedestalRun_008
new cal run Raw, test with put fifo full flags |