Entry  Sun Nov 23 00:20:41 2014, Axel König, Infineon, hardware run, Infineon_old_run003, 30000, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:?, H:?

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000994

DaqEvents: 30000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 00:58:04 2014, Axel König, AIDA, hardware run, AIDA_run012, 276006, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

Entry  Fri Nov 21 19:25:57 2014, Axel König, AIDA, hardware run, AIDA_run007, 26770, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

Entry  Sun Nov 23 00:51:07 2014, Axel König, Infineon, hardware run, Infineon_old_run005, 26569, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4609uA

(new table calibration): V:75, H:94.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000997

DaqEvents: 26569 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

 
Entry  Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = ? µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470
Entry  Fri Nov 21 23:40:10 2014, Axel König, AIDA, hardware run, AIDA_run010, 26329, , , Unknown 

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Sat Nov 22 00:11:36 2014, Axel König, AIDA, hardware run, AIDA_run011, 24916, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

Entry  Wed Nov 19 21:56:44 2014, Axel König, Infineon, hardware run, Infineon_run008, 244167, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0758 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167
Entry  Tue Nov 18 13:13:53 2014, Thomas Bergauer, Infineon, hardware run, infineon_run001, 225508, , , Unknown 

Infineon new stack - batch 4

single hit
 
HV=300V, total I = 4.2475 µA
 
strips horizontal
 
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
 
STOPPED by main User in H6B (18:11, 15:00)
 
Events: 225508
Next step: rearange modules vertically
 
Entry  Fri Nov 21 11:10:08 2014, Axel König, AIDA, hardware run, AIDA_run002, 211362, , , Unknown 

AIDA

multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
 
EUDAQ File: Run000962, Run000963, Run000964
 
config: L:\cern14\AIDA
data: L:\cern14\AIDA
 
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000
Entry  Fri Nov 21 12:14:46 2014, Axel König, AIDA, hardware run, AIDA_run003, 20617, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4240uA

(new table calibration): V:66mm, H:74mm

EUDAQ file:  Run000965

config: L:\cern14\AIDA

data: L:\cern14\AIDA

 

--Stopped 21.11 / 12:12--

DaqEvents: 20617 (-600 ped)

EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) 

Entry  Fri Nov 21 18:20:47 2014, Axel König, AIDA, hardware run, AIDA_run005, 20045, , , Unknown 

AIDA

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000979

--Stopped 21.11 / 12:12--

DaqEvents: 20045 (-600 ped)

EUDAQ EVENTS: ~18k

Entry  Sun Nov 23 01:05:43 2014, Hao Yin, Belle SVD, HardwareRun, 039, 20000, 2014-11-22 15:18:40, , Crap 

Cooled down to -20

Bias voltage set to +-80V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

 

Entry  Sun Nov 23 01:37:42 2014, Hao Yin, Belle SVD, HardwareRun, 040, 20000, 2014-11-23 01:37:00, , Unknown 

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

Entry  Sun Nov 23 12:17:59 2014, Benedikt Würkner, Belle SVD, HardwareRun, 044, 20000, , , Unknown 

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

Entry  Sun Nov 23 12:55:47 2014, Benedikt Würkner, Belle SVD, HardwareRun, 045, 20000, , , Unknown 

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

Entry  Sun Nov 23 00:24:15 2014, Axel König, Infineon, hardware run, Infineon_old_run004, 168725, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.6529uA

(new table calibration): V:81, H:88

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000996

DaqEvents: 168725 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Fri Nov 21 15:07:24 2014, Benedikt Würkner, Belle SVD, HardwareRun, 019, 150948, 2014-11-21 02:41:55, 2014-11-21 10:11:02, Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

Entry  Wed Nov 19 09:26:39 2014, Axel König, Infineon, hardware run, Infineon_run006, 1500, , , Unknown 

Infineon new stack - batch 4

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 91mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr)
Entry  Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown 

Infineon new stack - batch 4 

 
single hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
EUDAQ data: Run951 and Run952
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped 20.11 / 09:35-- 
 
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
 
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer)