| ID | Date | Author | Project | Subject  | Run Number | Events | StartTime | EndTime | Data | 
| 96 | Sat Nov 22 16:43:18 2014 | Axel König | common | table, telescope and dut geometry |  |  |  |  | Unknown | 
| geometry files | 
| Attachment 1: geometry_table.pdf | 
| Attachment 2: geometry_DUT.pdf | 
| Attachment 3: geometry_infineon_batch4.pdf | 
| Attachment 4: geometry_infineon_old.pdf | 
| 2 | Fri Nov 14 19:22:40 2014 | Martin Kurz | common | ip addresses, portforwarding, wlan |  |  |  |  | Unknown | 
| WLAN Router:SSID: Hephy password: 20supersecret14 DHCP Range: 192.168.0.200 to 239 Netmask: /24 DNS Server: 192.168.0.254 Gateway: 192.168.0.254 external IP: 128.141.61.16 (für diverse Port Forwardings)   Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen!  IP/MAC Zuweisung:
	
		
			| IP | Machine/Name | intern | Port Forwarding (aussen) |  
			| 192.168.0.10 | SVD Kenwood | VNC(5900) | VNC(9000) |  
			| 192.168.0.11 | AIDA DAQ | VNC(5900) | VNC(9001) |  
			| 192.168.0.12 | TUX DAQ | VNC(5900), VNC(5901), SSH(22) | VNC(9009), VNC(9002), SSH(9003), |  
			| 192.168.0.13 | Belle XY Tisch |  |  |  
			| 192.168.0.14 | TUXOA | SSH(22) | SSH(9004) |  
			| 192.168.0.15 | JTAG Server |  |  |  
			| 192.168.0.148 | alixcool |  |  |  
			| 192.168.0.16 | slowcontrol | VNC(5900) | VNC(9005) |  
			| 192.168.0.144 | CAEN Power supply |  |  |  
			| 192.168.0.17 | zenpixelwiki | SSH(22), VNC(5900) | SSH(9006), VNC(9008) |  
			| 192.168.0.18 | TLU (pcx25042, XY) | VNC(5900) | VNC(9007) |  
			| 192.168.0.240 | NI GPIB - ENET / 1000 |  |  |  
			| 192.168.0.150 | Printserver | VNC(5900) | VNC(9010) |  
			|  |  |  |  |  
			|  |  |  |  |    Admin Zugang Wlan Router:IP: 192.168.0.254 Username: admin password: Hephy2014   | 
| 5 | Fri Nov 14 19:52:12 2014 | Thomas Bergauer |  | important web pages |  |  |  |  | Unknown | 
| SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1 general Information about the Beam line(s): http://sba.web.cern.ch/sba/ | 
| 64 | Thu Nov 20 17:16:56 2014 | Axel König | common | how to run the EUDAQ offline monitor |  |  |  |  | Unknown | 
| YOU need 1.) Folder EUDAQ OFFLINE Monitor 2.) ROOT   Starting:  1.) open command line and chose the path where OfflineMonitor is 2.)Type -i "patch of raw file" -o test.root 100 3.) helpfile typing -h | 
| 85 | Fri Nov 21 23:33:54 2014 | Axel König | AIDA | hardware run (PC crashed) | AIDA_run008 | --- |  |  | Unknown | 
| 22:00 SVD3 PC crashed!!! data will be collected.  | 
| 29 | Tue Nov 18 13:13:53 2014 | Thomas Bergauer | Infineon | hardware run | infineon_run001 | 225508 |  |  | Unknown | 
| Infineon new stack - batch 4 single hit   HV=300V, total I = 4.2475 µA   strips horizontal   data file in L:\cern14\infineon\Infineon Run horiz config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg     STOPPED by main User in H6B (18:11, 15:00)   Events: 225508 Next step: rearange modules vertically   | 
| 31 | Tue Nov 18 18:33:31 2014 | Axel König | Infineon | hardware run | Infineon_run003 | 300000 |  |  | Unknown | 
| Infineon new stack - batch 4 single hit HV=300V, total I = 4.0044 µA strips vertical Table Position: H: 96mm V: 101mm data file in L:\cern14\infineon\Infineon Run vert config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg   --Stopped 18.11 / 20:20--- Reason: Enough events, adjusting new DUT position for next run Events: 300000 | 
| 36 | Tue Nov 18 23:04:34 2014 | Axel König | Infineon | hardware run | Infineon_run004 | 400000 |  |  | Unknown | 
| Infineon new stack - batch 4  single hit   HV=300V, total I = 4.0044 µA   strips vertical   Table Position: H: 96mm V: 81mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg   --stopped 18.11 // 23:05--- Reason: Enough events, next run with the same position but now multi six Events: 400000   | 
| 37 | Wed Nov 19 00:58:27 2014 | Axel König | Infineon | hardware run | Infineon_run005 | 87000 |  |  | Unknown | 
| Infineon new stack - batch 4  multi hit   HV=300V, total I = 4.0200 µA   strips vertical   Table Position: H: 96mm V: 81mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg   --stopped 19.11 // 01:00 -- Reason: Enough events, new dut postion for next multi run Events: 87000 | 
| 38 | Wed Nov 19 09:26:39 2014 | Axel König | Infineon | hardware run | Infineon_run006 | 1500 |  |  | Unknown | 
| Infineon new stack - batch 4 multi hit   HV=300V, total I = 4.0200 µA   strips vertical   Table Position: H: 96mm V: 91mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg   -- stopped -- 1500 Events only --> no trigger signals from TU (01:30 Uhr) | 
| 44 | Wed Nov 19 21:56:44 2014 | Axel König | Infineon | hardware run | Infineon_run008 | 244167 |  |  | Unknown | 
| Infineon new stack - batch 4  single hit   HV=300V, total I = 4.0758 µA   strips vertical   Table Position: H: 92.5mm V: 81mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg   --stopped 19.11 // 21:53 -- Reason: Want to run the eudaq for the next run Events: 244167 | 
| 45 | Wed Nov 19 22:15:41 2014 | Axel König | Infineon | hardware run | Infineon_run010 | 1498709 |  |  | Unknown | 
| Infineon new stack - batch 4    single hit   HV=300V, total I = 4.0200 µA   strips vertical   Table Position: H: 92.5mm V: 81mm   EUDAQ data: Run951 and Run952   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg   -- stopped 20.11 / 09:35--    SVD3DAQ Events: 1498709 EUDAQ Events: 2777   EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) | 
| 61 | Thu Nov 20 15:46:21 2014 | Axel König | Infineon | hardware run | Infineon_run012 | 263470 |  |  | Unknown | 
| Infineon new stack - batch 4  single hit   HV=300V, total I = ? µA   strips vertical   Table Position: H: 89mm V: 81mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg   --stopped 20.11 // 15:30 -- Eudaq: No Events build --> searching for failure Events: 263470 | 
| 62 | Thu Nov 20 15:47:56 2014 | Axel König | Infineon | hardware run | Infineon_run011 |  |  |  | Unknown | 
|  Infineon new stack - batch 4   faulty!!! | 
| 65 | Thu Nov 20 18:15:48 2014 | Axel König | Infineon | hardware run | Infineon_run013_voltage | 51273 |  |  | Unknown | 
| Infineon new stack - batch 4  single hit + eudaq   HV=100V, total I = 3.0326 µA   strips vertical   Table Position: H: 89mm V: 81mm   data file in L:\cern14\infineon\Infineon Run vert   config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg   eudaq file: run000959.raw   --stopped 20.11 // 18:10 -- Eudaq: 54928 Events: 51273 | 
| 69 | Fri Nov 21 11:10:08 2014 | Axel König | AIDA | hardware run | AIDA_run002 | 211362 |  |  | Unknown | 
| AIDA multi hit Voltage=100V, I=4.1688uA (new table calibration): V:56mm, H:96mm   EUDAQ File: Run000962, Run000963, Run000964   config: L:\cern14\AIDA data: L:\cern14\AIDA   --Stopped 21.11 / 10:30-- DaqEvents: 211362 EUDAQ EVENTS: ca. 41000 | 
| 70 | Fri Nov 21 12:14:46 2014 | Axel König | AIDA | hardware run | AIDA_run003 | 20617 |  |  | Unknown | 
| AIDA   single hit Voltage=100V, I=5.4240uA (new table calibration): V:66mm, H:74mm EUDAQ file:  Run000965 config: L:\cern14\AIDA data: L:\cern14\AIDA   --Stopped 21.11 / 12:12-- DaqEvents: 20617 (-600 ped) EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset])  | 
| 75 | Fri Nov 21 15:37:30 2014 | Axel König | AIDA | hardware run | AIDA_run004 | 7057 |  |  | Unknown | 
| AIDA   single hit Voltage=100V, I=5.4357uA (new table calibration): V:71mm, H:80mm   config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: Run000977 --Stopped 21.11 / 12:12-- DaqEvents: 7057 (-600 ped) EUDAQ EVENTS: 4658 (less than Daq)  | 
| 76 | Fri Nov 21 18:20:47 2014 | Axel König | AIDA | hardware run | AIDA_run005 | 20045 |  |  | Unknown | 
| AIDA single hit Voltage=100V, I=5.4357uA (new table calibration): V:71mm, H:80mm config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: Run000979 --Stopped 21.11 / 12:12-- DaqEvents: 20045 (-600 ped) EUDAQ EVENTS: ~18k | 
| 77 | Fri Nov 21 18:21:45 2014 | Axel König | AIDA | hardware run | AIDA_run006 | ~1k |  |  | Unknown | 
|  verwerfen! |