| ID | Date | Author | Project | Subject | Run Number | Events | StartTime | EndTime | Data | 
| 121 | Sun Nov 23 18:26:54 2014 | Markus Friedl | Belle SVD | HardwareRun | 005 | 60600 | 23.11.2014  18:24:34 | 23.11.2014 | Good | 
| Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides EUDAT telescope running with difference of 2 events | 
|  120 | Sun Nov 23 17:51:44 2014 | Benedikt Würkner | Belle SVD | HardwareRun | 046 | 100000 | 20:06 | 20:36 | Unknown | 
| Hardware Run +-60V Bias Room Temperature Pedestal 018 (again marked all the bad strips) Zero Suppressed   | 
| 119 | Sun Nov 23 16:55:37 2014 | Markus Friedl | Belle SVD | HardwareRun | 004 | 60600 | 23.11.2014  16:51:49 | 23.11.2014  18:23:54 | Good | 
| Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides EUDAT telescope running with difference of 2 events | 
| 118 | Sun Nov 23 15:13:37 2014 | Markus Friedl | Belle SVD | HardwareRun | 003 | 100600 | 23.11.2014  14:07:23 | 23.11.2014  16:51:27 | Good | 
| Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides EUDAT telescope running with difference of 2 events | 
| 117 | Sun Nov 23 15:10:42 2014 | Markus Friedl | Belle SVD | CalibrationRun | 001 | 83400 |  |  | Good | 
| Initial calibration run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side) | 
| 116 | Sun Nov 23 15:09:53 2014 | Markus Friedl | Belle SVD | PedestalRun | 001 | 10000 |  |  | Good | 
| Initial pedestal run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side) | 
| 115 | Sun Nov 23 15:07:54 2014 | Markus Friedl | Belle SVD | common |  |  |  |  | Unknown | 
| Geometry setup of FW/BW: (all dimensions are in mm and refer to the sensor planes) | 
| Attachment 1: fwbw_setup.png | 
|  | 
| 114 | Sun Nov 23 12:55:47 2014 | Benedikt Würkner | Belle SVD | HardwareRun | 045 | 20000 |  |  | Unknown | 
| Hardware Run +-50V Bias Room Temperature Pedestal 018 (again marked all the bad strips) Zero Suppressed | 
| 113 | Sun Nov 23 12:39:45 2014 | Axel König | common | PMT's of EUDET (Igor Rubinsky) |  |  |  |  | Unknown | 
| Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen). | 
| 112 | Sun Nov 23 12:17:59 2014 | Benedikt Würkner | Belle SVD | HardwareRun | 044 | 20000 |  |  | Unknown | 
| Hardware Run +-30V Bias Room Temperature Pedestal 017 (again marked all the bad strips) Zero Suppressed | 
| 111 | Sun Nov 23 10:51:49 2014 | Hao Yin | Belle SVD | HardwareRun | 042 | 76863 |  |  | Unknown | 
| Hardware Run +-40V Bias Room Temperature Pedestal 016 Zero Suppressed | 
| Attachment 1: Temp_23-11-14.PNG | 
|  | 
| 110 | Sun Nov 23 10:32:41 2014 | Hao Yin | Belle SVD | PedestalRun | 016 | 10000 |  |  | Unknown | 
| Pedestal Run  room temperature (30C) Bias scans planned | 
| 109 | Sun Nov 23 09:49:00 2014 | Markus Friedl | Belle SVD | cooling |  |  |  |  | Unknown | 
| Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases. Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.   | 
| Attachment 1: temp_last_night.png | 
|  | 
| 108 | Sun Nov 23 09:36:27 2014 | Axel König | Infineon | hardware run | Infineon_old_run006 | 526562 |  |  | Unknown | 
| Infineon old multi hit Voltage=300V, I=10.4028uA (new table calibration): V:75, H:95 config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: run000998 DaqEvents: 526562 (-600 ped) EUDAQ EVENTS: daq events - 600 (+2 offset)   | 
| 107 | Sun Nov 23 09:32:48 2014 | Axel König | Infineon | hardware run | Infineon_old_run007 | 63913 |  |  | Unknown | 
| Infineon old multi hit Voltage=300V, I=10.4028uA (new table calibration): V:75, H:96.5 config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: run000999 DaqEvents: 63913 (-600 ped) EUDAQ EVENTS: daq events - 600 (+2 offset)   | 
| 106 | Sun Nov 23 01:37:42 2014 | Hao Yin | Belle SVD | HardwareRun | 040 | 20000 | 2014-11-23 01:37:00 |  | Unknown | 
| Bias voltage set to +-80V Pedestal_015 (cooled)  "New" layout with no cooling (CO2 is no more) Newly set values for APC Delay New FIR Run 005 Temperature around 30 C Bias: +-80V | 
| 105 | Sun Nov 23 01:05:43 2014 | Hao Yin | Belle SVD | HardwareRun | 039 | 20000 | 2014-11-22 15:18:40 |  | Crap | 
| Cooled down to -20 Bias voltage set to +-80V Pedestal_013 (cooled) Noisefile: HardwareRun_036.noi   | 
| 103 | Sun Nov 23 00:51:07 2014 | Axel König | Infineon | hardware run | Infineon_old_run005 | 26569 |  |  | Unknown | 
| 
    
        
            | Infineon old multi hit Voltage=300V, I=10.4609uA (new table calibration): V:75, H:94.5 config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: run000997 DaqEvents: 26569 (-600 ped) EUDAQ EVENTS: daq events - 600 (+2 offset)    |  | 
| 102 | Sun Nov 23 00:24:15 2014 | Axel König | Infineon | hardware run | Infineon_old_run004 | 168725 |  |  | Unknown | 
| Infineon old multi hit Voltage=300V, I=10.6529uA (new table calibration): V:81, H:88 config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: run000996 DaqEvents: 168725 (-600 ped) EUDAQ EVENTS: daq events - 600 (+2 offset)  | 
| 101 | Sun Nov 23 00:20:41 2014 | Axel König | Infineon | hardware run | Infineon_old_run003 | 30000 |  |  | Unknown | 
| Infineon old multi hit Voltage=300V, I=10.9797uA (new table calibration): V:?, H:? config: L:\cern14\AIDA data: L:\cern14\AIDA EUDAQ File: run000994 DaqEvents: 30000 (-600 ped) EUDAQ EVENTS: daq events - 600 (+2 offset)  |