Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 1 of 6  Not logged in ELOG logo
Entry  Sun Nov 23 16:55:37 2014, Markus Friedl, Belle SVD, HardwareRun, 004, 60600, 23.11.2014 16:51:49, 23.11.2014 18:23:54, Good 

Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry  Sun Nov 23 15:13:37 2014, Markus Friedl, Belle SVD, HardwareRun, 003, 100600, 23.11.2014 14:07:23, 23.11.2014 16:51:27, Good 

Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry  Sun Nov 23 18:26:54 2014, Markus Friedl, Belle SVD, HardwareRun, 005, 60600, 23.11.2014 18:24:34, 23.11.2014 , Good 

Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry is currently edited by Thomas Bergauer on 193.170.243.91  Entry  Sun Nov 23 17:51:44 2014, Benedikt Würkner, Belle SVD, HardwareRun, 046, 100000, 20:06, 20:36, Unknown 

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

Entry  Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown SPS_Testbeam-Temp.xlsxScreen_Shot_2014-11-22_at_12.41.44.png

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Entry  Fri Nov 21 15:07:24 2014, Benedikt Würkner, Belle SVD, HardwareRun, 019, 150948, 2014-11-21 02:41:55, 2014-11-21 10:11:02, Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

Entry  Fri Nov 14 19:01:27 2014, Thomas Bergauer, common, Administrative Procedures for Departure, , , , , Unknown Merchandise-2014.pdfankunftsbestaetigung.pdf

Wednesday:

* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt werden, was in der Zone war (also nicht im Counting room)

Merchandise-Bestätigung für die Anreise ist im attachment!

 

Anreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5855845

Abreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5863835

Entry  Fri Nov 14 19:22:40 2014, Martin Kurz, common, ip addresses, portforwarding, wlan, , , , , Unknown 

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.61.16 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.10 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 AIDA DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22)  SSH(9004)
192.168.0.15 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
       

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

Entry  Fri Nov 14 19:47:25 2014, Thomas Bergauer, , Telefonnummern, , , , , Unknown 

* CCC (zentraler Beschleuniger-Kontrollraum): 77500

* H6A Controlroom: 76755

* HEPHY-Handy: 16-2471 or +41 76 487 2471 from outside of CERN

* Office in Meyrin: 12-R11: 74592

 

Hostel-Zimmern:

* Bergi: 79326

* Benni: 60232

* Hao: 70408

 

Andere Wichtige Leute:

* Beam-Dame: Edda Gschwendner 16-5080

* NA Hallen Verantwortlicher: Michael Jeckel

Lookup Telefonnummern: http://phonebook.cern.ch

 
Entry  Fri Nov 14 19:49:04 2014, Florian Buchsteiner, common, Belle Setup, , , , , Unknown SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
 
Entry  Fri Nov 14 19:52:12 2014, Thomas Bergauer, , important web pages, , , , , Unknown 

SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

general Information about the Beam line(s): http://sba.web.cern.ch/sba/

Entry  Sat Nov 15 11:36:41 2014, Thomas Bergauer, common, Checklist for North Area access, , , , , Unknown 

 

Checklist for North Area access: 

  • Dosimeter (http://dosimetry.web.cern.ch/en)
  • Helmet and safety shoes (http://gs-dep.web.cern.ch/en/content/stores_hours)
  • Access right to H6A control room (request via EDH): Control Room HNA-447 (0887-1-Q45). Activate access right on your CERN access card at one of the validation stations (https://espace.cern.ch/service-access-control/default.aspx)
  • For using CERN rental car, request "CERN vehicle driving license (V)" via EDH
  • Park in front of bldg. 890. Walk to North Hall (bldg. 887) through bldg. 907. Swipe dosimeter in front of electronic lock next to the entrance door. Turn left inside bldg. 887. Control room Q45 is on the left-hand side of the upper level. Swipe CERN access card in front of electronic lock.
Entry  Sat Nov 15 11:37:19 2014, Thomas Bergauer, AIDA, List of EUDET Telescope PCs in H6b, , , , , Unknown 

 https://twiki.cern.ch/twiki/bin/view/CLIC/ClicPixelDataTakingCERNPS2014

Entry  Sat Nov 15 12:41:50 2014, Benedikt Würkner, Belle SVD, Discoveries during preliminary sensor tests, , , , , Unknown weird_signal.pngfaulty-signal-l4_n.pngfaulty-signal_l4_n_2.png

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Entry  Sun Nov 16 14:22:51 2014, Thomas Bergauer, AIDA, PC Configuration EUDET Telescope in H6b, , , , , Unknown 

PC (gehört AIDA) in H6b control room:  ssh telescope@pcaidatb.cern.ch

 

 

Entry  Sun Nov 16 21:37:56 2014, Hao Yin, common, AIM, , , , , Unknown 

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

Entry  Mon Nov 17 19:23:57 2014, Thomas Bergauer, Infineon, PI XY table initial position, , , , , Unknown 

initial position of Infineon Stack (PI Micromove):
(guess center position by eye)

STRIPS IN HORIZONTAL DIRECTION

* vertical axis: M511.DD: Zero position 81.0mm / higher values correspond to lowering the table

* vertical axis: M521.DD: Zero position 96.0mm / higher values correspond to move the table to the table mounting

Entry  Mon Nov 17 22:03:02 2014, Martin Kurz, common, Drucker, , , , , Unknown 

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

Entry  Mon Nov 17 22:18:27 2014, Hao Yin, Belle SVD, ADC delay scan, , , Mon Nov 17 22:08:29, , Unknown 

L3-p: 18

L4-p: 36

L5-p: 33

L6-p: 39

 

L3-n: 18

L4-n: 36

L5-n: 36

L6-n: 35

Entry  Mon Nov 17 22:21:41 2014, Hao Yin, , FIR run, 001, , Mon Nov 17 22:08:29 CET 2014, , Good 

Excellent, brilliant run. 

ELOG V3.1.5-fc6679b