Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 1 of 6  Not logged in ELOG logo
Entry  Fri Nov 14 19:01:27 2014, Thomas Bergauer, common, Administrative Procedures for Departure, , , , , Unknown Merchandise-2014.pdfankunftsbestaetigung.pdf
Wednesday:
* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH
Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt
Entry  Fri Nov 14 19:22:40 2014, Martin Kurz, common, ip addresses, portforwarding, wlan, , , , , Unknown 
WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239
Entry  Fri Nov 14 19:47:25 2014, Thomas Bergauer, , Telefonnummern, , , , , Unknown 
* CCC (zentraler Beschleuniger-Kontrollraum): 77500
* H6A Controlroom: 76755
* HEPHY-Handy: 16-2471 or +41 76 487 2471 from outside of CERN
Entry  Fri Nov 14 19:49:04 2014, Florian Buchsteiner, common, Belle Setup, , , , , Unknown SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
 
Entry  Fri Nov 14 19:52:12 2014, Thomas Bergauer, , important web pages, , , , , Unknown 
SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1
general Information about the Beam line(s): http://sba.web.cern.ch/sba/
Entry  Sat Nov 15 11:36:41 2014, Thomas Bergauer, common, Checklist for North Area access, , , , , Unknown 
 
Checklist for North Area access: 
Entry  Sat Nov 15 11:37:19 2014, Thomas Bergauer, AIDA, List of EUDET Telescope PCs in H6b, , , , , Unknown 
 https://twiki.cern.ch/twiki/bin/view/CLIC/ClicPixelDataTakingCERNPS2014
Entry  Sat Nov 15 12:41:50 2014, Benedikt Würkner, Belle SVD, Discoveries during preliminary sensor tests, , , , , Unknown weird_signal.pngfaulty-signal-l4_n.pngfaulty-signal_l4_n_2.png
L5_p_side APV #3 faulty signal
L4_n_side APV #2 and #3 faulty signal
Entry  Sun Nov 16 14:22:51 2014, Thomas Bergauer, AIDA, PC Configuration EUDET Telescope in H6b, , , , , Unknown 
PC (gehört AIDA) in H6b control room:  ssh telescope@pcaidatb.cern.ch
 
Entry  Sun Nov 16 21:37:56 2014, Hao Yin, common, AIM, , , , , Unknown 
fachi:  aimhephy@antispam.e4ward.com
chrisu:  gargamel0971
flo: flo.bux@sbg.at
Entry  Mon Nov 17 19:23:57 2014, Thomas Bergauer, Infineon, PI XY table initial position, , , , , Unknown 
initial position of Infineon Stack (PI Micromove):
(guess center position by eye)
STRIPS IN HORIZONTAL DIRECTION
Entry  Mon Nov 17 22:03:02 2014, Martin Kurz, common, Drucker, , , , , Unknown 
Drucken über den Printserver (192.168.0.150):
 
MAC:
Entry  Tue Nov 18 12:35:32 2014, Axel König, common, Infineon (4 modules) TLU Settings, , , , , Unknown 

     VNC to 192.168.0.18

   In command line: cd C:\Users\telescope\eudaq\bin

   TLUControl.exe.exe -d 2 -a 11 - i RJ45

Operating with AIDA telescope: 
Entry  Tue Nov 18 13:13:53 2014, Thomas Bergauer, Infineon, hardware run, infineon_run001, 225508, , , Unknown 
Infineon new stack - batch 4
single hit
 
HV=300V, total I = 4.2475 µA
 
strips horizontal
 
data
file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
 
STOPPED
Entry  Tue Nov 18 18:29:55 2014, Axel König, Infineon, calibration run, Infineon_run002, , , , Unknown 
Infineon_run002 is just a calibration run for the vertical positioned sensors. 
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
Entry  Tue Nov 18 18:33:31 2014, Axel König, Infineon, hardware run, Infineon_run003, 300000, , , Unknown 
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
Entry  Tue Nov 18 20:42:18 2014, Benedikt Würkner, Belle SVD, Coordinates of the DUT, , , , , Unknown 
We set the coordinates trying to put the beam in an area with well working APVs
Peak of course differs for n and p sensors due to their different pitch.
L4-6 n-side Peak around strip 180
Entry  Tue Nov 18 23:04:34 2014, Axel König, Infineon, hardware run, Infineon_run004, 400000, , , Unknown 
Infineon new stack - batch 4 
single hit
 
HV=300V, total I = 4.0044 µA
 
strips vertical
 
Table
Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon
Entry  Wed Nov 19 00:58:27 2014, Axel König, Infineon, hardware run, Infineon_run005, 87000, , , Unknown 
Infineon new stack - batch 4 
multi hit
 
HV=300V, total I = 4.0200 µA
 
Entry  Wed Nov 19 09:26:39 2014, Axel König, Infineon, hardware run, Infineon_run006, 1500, , , Unknown 
Infineon new stack - batch 4
multi hit
 
HV=300V, total I = 4.0200 µA
 
ELOG V3.1.5-fc6679b