Fri Nov 21 18:21:45 2014, Axel König, AIDA, hardware run, AIDA_run006, ~1k, , , Unknown
|
verwerfen! |
Fri Nov 21 15:10:19 2014, Benedikt Würkner, , HardwareRun, 15-22 (exept 19) , none, , , Crap
|
|
Fri Nov 21 15:03:08 2014, Benedikt Würkner, Belle SVD, HardwareRun, 014, 989, , , Unknown
|
cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed |
Wed Nov 19 00:58:27 2014, Axel König, Infineon, hardware run, Infineon_run005, 87000, , , Unknown
|
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000 |
Sun Nov 23 15:10:42 2014, Markus Friedl, Belle SVD, CalibrationRun, 001, 83400, , , Good
|
Initial calibration run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side) |
Sun Nov 23 10:51:49 2014, Hao Yin, Belle SVD, HardwareRun, 042, 76863, , , Unknown
|
Hardware Run +-40V Bias
Room Temperature
Pedestal 016
Zero Suppressed |
Fri Nov 21 15:37:30 2014, Axel König, AIDA, hardware run, AIDA_run004, 7057, , , Unknown
|
AIDA
single hit
Voltage=100V, I=5.4357uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000977
--Stopped 21.11 / 12:12--
DaqEvents: 7057 (-600 ped)
EUDAQ EVENTS: 4658 (less than Daq) |
Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:96.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000999
DaqEvents: 63913 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 16:55:37 2014, Markus Friedl, Belle SVD, HardwareRun, 004, 60600, 23.11.2014 16:51:49, 23.11.2014 18:23:54, Good
|
Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides
EUDAT telescope running with difference of 2 events |
Sun Nov 23 18:26:54 2014, Markus Friedl, Belle SVD, HardwareRun, 005, 60600, 23.11.2014 18:24:34, 23.11.2014 , Good
|
Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides
EUDAT telescope running with difference of 2 events |
Sat Nov 22 07:56:33 2014, Axel König, AIDA, hardware run, AIDA_run013, 55629, , , Unknown
|
AIDA
multi hit
Voltage=100V, I=5.3417uA
(new table calibration): V:51mm, H:45mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000990
DaqEvents: 55629 (-600 ped)
EUDAQ EVENTS: 55003
|
|
Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:97mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000992
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:102mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000993
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:95
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000998
DaqEvents: 526562 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown
|
Infineon new stack - batch 4
single hit + eudaq
HV=100V, total I = 3.0326 µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
eudaq file: run000959.raw
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273 |
Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown
|
Not completely cooled since cooling failed at 1:42 in the night
Bias voltage set to +-60V
Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA
Pedestal_013 (cooled)
Noisefile: HardwareRun_036.noi |
Sat Nov 22 15:31:49 2014, Hao Yin, Belle SVD, HardwareRun, 038, 43788, 2014-11-22 15:18:40, , Unknown
|
Cooled down to -20
Bias voltage set to +-60V
Pedestal_013 (cooled)
Noisefile: HardwareRun_036.noi
Zero suppressed |
Tue Nov 18 23:04:34 2014, Axel König, Infineon, hardware run, Infineon_run004, 400000, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
|
Fri Nov 21 23:34:36 2014, Axel König, AIDA, hardware run, AIDA_run009, 32902, , , Unknown
|
AIDA
multi hit
Voltage=100V, I=5.2190uA
(new table calibration): V:71mm, H:100mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000983
--Stopped 21.11 / 19:20--
DaqEvents: 32902 (-600 ped)
EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)
|
|
Tue Nov 18 18:33:31 2014, Axel König, Infineon, hardware run, Infineon_run003, 300000, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 101mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--Stopped 18.11 / 20:20---
Reason: Enough events, adjusting new DUT position for next run
Events: 300000 |
|