| ID | Date | Author | Project | Subject | Run Number | Events | StartTime | EndTime | Data  |  | 52 | Tue Oct 23 08:22:42 2012 | Markus Friedl | MicronOrigami_gross | run | run025 | 100000 | 23.10.2012  08:21:37 | 23.10.2012  13:47:09 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-15V, Ibias=47uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 |  | 53 | Tue Oct 23 13:50:44 2012 | Markus Friedl | MicronOrigami_gross | cal | cal025 | 83800 | 23.10.2012  13:47:09 | 23.10.2012  14:35:05 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-15V, Ibias=48uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 |  | 54 | Tue Oct 23 15:55:58 2012 | Markus Friedl | MicronOrigami_gross | cal | cal026 | 83800 | 23.10.2012  14:56:47 | 23.10.2012  15:42:17 | Good |  | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-10V, Ibias=36uA
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
 |  | 60 | Sat Oct 27 00:43:55 2012 | Christian Irmler | MicronBaby | cal | cal029 | 83800 | 27.10.2012  00:10:15 | 27.10.2012  00:36:55 | Good |  | After irradiation   Micron baby stack after gamma irrdiationHV = -100 V
 I = -58 uA
 |  | 61 | Sat Oct 27 01:13:47 2012 | Christian Irmler | MicronBaby | run | run029 | 307k | 27.10.2012  01:02:49 | 27.10.2012  07:36:34 | Good |  | After irradiation xy-table: x=319.4, y=74.6beam hits APV0
 Micron baby stack after gamma irrdiationHV = -100 V
 I = -58 uA
 |  | 62 | Sat Oct 27 07:51:49 2012 | Manfred Valentan | MicronBaby | run | run030 | 376678 | 27.10.2012  07:49:09 | 27.10.2012  17:32:07 | Good |  | After irradiation xy-table: x=319.4, y=87.6beam hits APV1
 Micron baby stack after gamma irrdiationHV = -100 V
 I = -58 uA
 |  | 63 | Sat Oct 27 19:36:24 2012 | Markus Friedl | MicronOrigami_gross | cal | cal031 | 83800 | 27.10.2012  19:59:50 | 27.10.2012  20:44:38 | Good |  | Belle stack 2 after irradiation HV = +50V -50V I = 112 µA CO2 cooling |  | 64 | Sat Oct 27 21:49:08 2012 | Markus Friedl | MicronOrigami_gross | run | run031 | 150k | 27.10.2012  21:42:46 | 28.10.2012  02:35:55 (+1h due to winter time) | Good |  | Belle stack 2 after gamma irrdiationHV = +50V -50 V
 I = 102 uA
 CO2 cooling
   |  | 65 | Sun Oct 28 02:51:49 2012 | Markus Friedl | MicronOrigami_gross | run | run032 | 150k | 28.10.2012  02:47:24 | 28.10.2012  08:31:19 | Good |  | Belle stack 2 after gamma irradiation HV = +50V -50V I = 101 uA Bias currents absolutely stable during the whole run. CO2 cooling hitting APV3 (n side) = wide side of wedge sensor |  | 67 | Sun Oct 28 15:46:07 2012 | Markus Friedl | MicronBaby | cal | cal034 | 83800 | 28.10.2012  15:19:10 | 28.10.2012  15:40:47 | Good |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 33 uA
 |  | 68 | Sun Oct 28 16:22:35 2012 | Christian Irmler | MicronBaby | run | run034 | 101864 | 28.10.2012  16:12:24 | 28.10.2012  18:34:24 | Good |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 36.3 uA
 Position APV0 of all sensors X-Y Table coordinates:X=0 / Y=-1  (afterwards: nulled)
 PC power cut after ~100k events |  | 69 | Sun Oct 28 20:07:28 2012 | Markus Friedl | MicronBaby | run | run035 | 304110 | 28.10.2012  20:01:48 | 29.10.2012  03:50:44 | Good |  | Micron Baby stack 2 after irradiation (intermediate strips)HV = -100 V
 I = 39 uA
 
 DESY table shifted by 2.5mm (beam down) after beam profile was changed (to get higher intensity) beam hitting lower APVs |  | 71 | Mon Oct 29 11:36:40 2012 | Markus Friedl | Infineon | cal | cal037 | 83800 | 29.10.2012  11:35:12 | 29.10.2012  11:58:02 | Good |  | Infineon stack Version 2 after irradiationHV = +300 V
 I = 137 A
 
 |  | 72 | Mon Oct 29 12:24:41 2012 | Markus Friedl | Infineon | run | run037 | 301382 | 29.10.2012  12:22:22 | 29.10.2012  21:05:57 | Good |  | Infineon stack Version 2 after irradiationHV = +300 V
 I = 162 A
 
 hitting upper part of strixels and baby, vertically ~centered |  | 73 | Mon Oct 29 22:36:52 2012 | Markus Friedl | HPK_baby | cal | cal038 | 83800 | 29.10.2012  22:17:34 | 29.10.2012  22:47:47 | Good |  | HPK baby stack after irradiation with partial cooling (HPK neutron & HPK neutron/gamma)HV = +75 Vm  -75V
 I =  226A
 
   Temp sensors configuration: 11   HPK Neutron n in 12   HPK Neutron n -> p 13   ---- 14   HPK Neutron p -> Gamma p 15   Gamma p -> n 16   Neutron Gamma n out |  | 75 | Tue Oct 30 10:37:19 2012 | Markus Friedl | HPK_baby | cal | cal039 | 83800 | 30.10.2012  10:35:35 | 30.10.2012  11:02:06 | Good |  | Turned off cooling, now taking warm data   HPK baby stack after irradiation - no coolingI =  200A and growing (warming up)
 positioned centered on p and n
 
   
 |  | 22 | Mon Oct 15 19:40:03 2012 | Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run009 | 31650 | 15.10.2012  19:28:30 | 15.10.2012  22:08:31 | Crap |  | ATTENTION! Bias voltage was +-100 V instead of +-50 V  Origami Stack 2: Origami #4, #3, Wedge new1, oldHV = +-100V
 Ibias=12.3µA
 beam position:vertical: between APV 1&2 (of 6)
 horizontal: centered on APV#1 ->  right side of sensor
 Position of xy table:x = 23, y = -25
 Temperatures:
 Origami #4: In=-33 degC / Out=-34 degCOrigami #3: Out=-35 degC (temperatur sensor of inlet is not working)
 Wedge new 1: Out =  -17 degC, cooling block = -14 degC
 Wedge old: Out = -16 degC, cooling block = -14 degC
   15.10.2012  22:08:31  event=0  rate=0events/s temp/curr=31.3/089.2 31.3/-16.2 31.2/-17.9 31.3/-18.2 29.9/003.6 29.9/003.1 30.0/-01.1 29.9/-01.6 
 Stopped after 31650 events, because of PS problems and no beam. |  | 24 | Mon Oct 15 23:26:52 2012 | Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run010 | 158k | 15.10.2012  23:10:40 | 16.10.2012  05:05:35 | Crap |  | ATTENTION: Bias voltage was +-100 V instead of +- 50 V Same as run009. Origami Stack 2: Origami #4, #3, Wedge new1, oldHV = +-10V
 Ibias=12.3µA
 beam position:vertical: between APV 1&2 (of 6)
 horizontal: centered on APV#1 ->  right side of sensor -> small side of wedge sensors
 Position of xy table:x = 23, y = -25
 Temperatures:
 Origami #4: In=-33 degC / Out=-34 degCOrigami #3: Out=-35 degC (temperatur sensor of inlet is not working)
 Wedge new 1: Out =  -17 degC, cooling block = -14 degC
 Wedge old: Out = -16 degC, cooling block = -14 degC
   15.10.2012  22:08:31  event=0  rate=0events/s temp/curr=31.3/089.2 31.3/-16.2 31.2/-17.9 31.3/-18.2 29.9/003.6 29.9/003.1 30.0/-01.1 29.9/-01.6 
 |  | 25 | Tue Oct 16 05:24:21 2012 | Christian Irmler | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run011 | 150k | 16.10.2012  05:19:28 | 16.10.2012  09:59:24 | Crap |  | ATTENTION: Bias voltage was +-100 V instead of +- 50 V Origami Stack 2: Origami #4, #3, Wedge new1, old HV = +-100V Ibias=12.3µA
 beam position:vertical: between APV 1&2 (of 6)
 horizontal: centered on APV#3 ->  left side of sensor -> wide side of wedge sensors
 Position of xy table:x = 83, y = -25
 Temperatures:
 Origami #4: In=-33 degC / Out=-34 degCOrigami #3: Out=-35 degC (temperatur sensor of inlet is not working)
 Wedge new 1: Out =  -17 degC, cooling block = -16 degC
 Wedge old: Out = -15 degC, cooling block = -15 degC
   Stopped after 132658 events, because of empty gas bottle and thus insufficient cooling. |  | 37 | Fri Oct 19 00:45:52 2012 | Markus Friedl | MicronOrigami_gross | run | run016 | 11855 | 19.10.2012  00:24:05 | 19.10.2012  00:48:24 | Crap |  |   Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2HV = +-50V, Ibias=77A
 Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
 = p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
 = n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
   Stack is now positioned on globally best performing position which should also enable reasonable tracking. Trigger timing not perfect, needs adjustment (-1 CLK) -> new run |  |