ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
12
|
Mon Sep 19 17:40:47 2011 |
Manfred Valentan | Micron | Module SPRAY-2 | | | | | |
Sensor: B2Micron_2825_05_Baby4
p-stop: p-spray WITHOUT intermediate strips
Hybrid p-side: H44 (reused from last year)
Hybrid n-side: MB6 |
13
|
Mon Sep 19 17:41:27 2011 |
Manfred Valentan | Micron | Module SPRAY-I-2 | | | | | |
Sensor: B2Micron_2825_15_Baby3
p-stop: p-spray WITH intermediate strips
Hybrid p-side: H43 (reused from last year)
Hybrid n-side: MB7 |
14
|
Mon Sep 19 17:42:01 2011 |
Manfred Valentan | Micron | Module SPRAY-1 | | | | | |
Sensor: B2Micron_2825_05_Baby3
p-stop: p-spray WITHOUT intermediate strips
Hybrid p-side: H32 (reused from last year)
Hybrid n-side: MB8 |
15
|
Mon Sep 19 17:42:39 2011 |
Manfred Valentan | Micron | Module SPRAY-I-1 | | | | | |
Sensor: B2Micron_2825_15_Baby2
p-stop: p-spray WITH intermediate strips
Hybrid p-side: MB1
Hybrid n-side: MB9 |
16
|
Mon Sep 19 17:44:00 2011 |
Manfred Valentan | Micron | Module COMM-1 | | | | | |
Sensor: B2Micron_2826_19_Baby2 (reused from last year, was TRK7)
p-stop: Common, with intermediate strips
Hybrid p-side: H46
Hybrid n-side: M37 |
17
|
Mon Sep 19 17:44:39 2011 |
Manfred Valentan | Micron | Module COMB-1 | | | | | |
Sensor: B2Micron_2826_01_Baby4 (reused from last year, was TRK6)
p-stop: Combined, with intermediate strips
Hybrid p-side: H45
Hybrid n-side: M36 |
18
|
Mon Sep 19 17:46:07 2011 |
Manfred Valentan | Micron | Module ATOLL-1 | | | | | |
Sensor: B2Micron_2826_07_Baby3 (reused from last year, but was not used in beam test SPS2010)
p-stop: Atoll, with intermediate strips
Hybrid p-side: H40
Hybrid n-side: M30 |
19
|
Mon Sep 19 17:47:11 2011 |
Manfred Valentan | Micron | Module COMB-IRRAD | | | | | |
Sensor: B2Micron_2826_19_Baby4 (reused from last year, was DUT4, module is irradiated to 700 kGy)
p-stop: Combined, with intermediate strips, irradiated
Hybrid p-side: H48
Hybrid n-side: M35 |
20
|
Mon Sep 19 17:47:50 2011 |
Manfred Valentan | Micron | Module COMM-IRRAD | | | | | |
Sensor: B2Micron_2826_07_Baby2 (reused from last year, was DUT3, module is irradiated to 700 kGy)
p-stop: Common, with intermediate strips, irradiated
Hybrid p-side: H41
Hybrid n-side: M31 |
21
|
Mon Oct 3 20:30:14 2011 |
Thomas Bergauer | common | XY Tisch | | | | | |
Grosser (DESY) Tisch: x = -342.0 y = 343.0 (Einheiten unbekannt, möglicherweise mm)
Raten-Scan siehe gescannter Zettel im Attachment.
erster Wert: X, also horizontal (positive Zahlen: Saleve side = Restaurant Nr. 3)
zweiter Wert: Z, also Höhe (positive Zahlen nach unten)
Micron DUT: X:324, Z:103 [Einheiten in mm]
configuration: IP-Address 192.168.0.13; 2 Achsen |
23
|
Mon Oct 3 21:08:27 2011 |
Manfred Valentan | Micron | Micron-Baby-Stack p-stop, configuration | | | | | |
Photo of hand-drawn stack configuration, config files |
35
|
Wed Oct 5 17:54:09 2011 |
Christian Irmler | BELLE | Origami stack cooled | cal007 | 83800 | 05.10.2011 17:51:57 | | Good |
I2C setting modified to improve the shape of the p-side signal --> shaping time reduced, pulse height still low
Origami6
HV=+-40V
beam on
CO2 cooling:
preassure @ P_TT_4 = 18.2 bar
mass flow = 0.9 g/s
I=18.0µA
longterm files
It-pos-0510111531.txt
It-neg-0510111531.txt
currents and temperatures:
05.10.2011 17:53:00 event=2900 rate=47events/s temp/curr=35.3/-05.6 35.3/-06.0 35.3/-06.9 34.6/001.9 34.8/002.2 34.8/020.7
|
36
|
Wed Oct 5 19:33:40 2011 |
Markus Friedl | common | Trigger condition | | | 4.10.2011 15:00 | | |
Changed trigger such that off-spill scintillator triggers are vetoed.
Inserted Flip-Flop which is set by begin of spill (WWE) and reset by end of spill signal (EE). Out-bar is put in coincidence with the scintillator trigger.
This also changes the timing, which was unfortunately not detected until 30 hours later. Thus, runs 4-7 have bad (wrong) timing -> UNUSABLE |
45
|
Fri Oct 7 18:28:53 2011 |
Christian Irmler | common | run schedule | | | | | Unknown |
|
49
|
Sat Oct 8 09:30:44 2011 |
Christian Irmler | BELLE | Cooling plant tests | | | 08.10.2011 09:30 | | Unknown |
Software run with 6 samples to ensure that APV chips dissipate full power.
DAQ data not saved, bias current monitored
new longterm files:
It-neg-0810110926.txt
It-pos-0810110926.txt |
50
|
Sat Oct 8 14:33:25 2011 |
Thomas Bergauer | HPK | baby_std | run016 | 250k | 08.10.2011 14:31:40 | | Crap |
falsches config file (single statt multi6)
no cooling
beam on; xy table position x=322 y=80
HV=200V Istart_PY=7.6uA; Istart_N=0.42
std. I2C settings |
51
|
Sat Oct 8 16:35:04 2011 |
Thomas Bergauer | HPK | baby_std | run017 | | 08.10.2011 16:26:10 | | Crap |
wrong timing
no cooling
beam on; xy table position x=322 y=80
HV=200V Istart_PY=7.6uA; Istart_N=0.42
std. I2C settings |
56
|
Sun Oct 9 10:13:11 2011 |
Karl-Heinz Hoffmann | HPK | baby_add | cal011 | 83800 | 09.10.2011 10:05:01 | | Good |
no cooling
beam on; xy table position x= y=
HV=200V Istart_P=1.5uA; Istart_N=0.22uA
std. I2C settings |
58
|
Sun Oct 9 11:28:30 2011 |
Manfred Valentan | HPK | HPK BSTD stack configuration | | | | | Unknown |
Module order:
BSTD1-N
BSTD2-N
BADD1-N (for z information)
BSTD1-P
BSTD1-Y
BSTD2-P
BSTD2-Y
Talk from Marko on Testbeam with HPK Double Metal Sensors |
59
|
Sun Oct 9 11:31:43 2011 |
Manfred Valentan | HPK | HPK BADD stack configuration | | | | | Unknown |
Module order:
BADD1-N
BADD2-N
BSTD1-N (for z information)
BADD1-P
BADD1-Y
BADD2-P
BADD2-Y
Talk from Marko on Testbeam with HPK Double Metal Sensors |