Wed May 18 12:06:42 2011, Manfred Valentan, Micron Baby, DUT4, source run, irrad, prezupf, cal114, 83800, 18.05.2011 11:42:22, 18.05.2011 11:50:36
|
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/prezupf/micronbaby_single_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=104µA |
Wed May 18 10:12:32 2011, Manfred Valentan, Micron Baby, DUT3, source run, unirrad, prezupf, cal113, 83800, 18.05.2011 09:42:08, 18.05.2011 09:50:23
|
DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=13µA
I_end=20µA |
Tue May 17 18:49:16 2011, Manfred Valentan, Micron Baby, B2Micron_2826_7_baby3, source run, unirrad, prezupf, cal112, 83800, 17.05.2011 18:50:50, 17.05.2011 18:59:04
|
B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.2µA
I_end=1.4µA |
Tue May 17 17:44:12 2011, Manfred Valentan, Micron Baby, GEW8, source run, unirrad, prezupf, cal111, 83800, 17.05.2011 17:51:50, 17.05.2011 18:00:02
|
GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.6µA |
Tue May 17 15:10:52 2011, Manfred Valentan, Micron Baby, TRK7, source run, unirrad, prezupf, cal110, 83800, 17.05.2011 15:16:25, 17.05.2011 15:24:35
|
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=1.7µA |
Tue May 17 14:36:36 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, prezupf, cal109, 83800, 17.05.2011 14:18:13, 17.05.2011 14:34:25
|
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.8µA |
Tue May 17 13:31:32 2011, Manfred Valentan, Micron Baby, TRK2, source run, unirrad, prezupf, cal108, 83800, 17.05.2011 13:17:17, 17.05.2011 13:25:27
|
TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA |
Tue May 17 13:02:34 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, cal107, 83800, 17.05.2011 12:20, 17.05.2011 12:35
|
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA |
Wed May 11 16:28:20 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf, cal106, 100k, 11.05.2011 16:00, 11.05.2011 16:25
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA
DAQ modified so that only strips marked as good are considered when calculating the common mode correction. |
Wed Apr 13 12:13:09 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf ** DO NOT USE **, cal105, 83800, 13.04.2011 12:02:41, 13.04.2011 12:10:55
|
DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA
data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!! |
Mon Apr 11 18:25:35 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal104, 83800, 11.04.2011 18:12:38, 11.04.2011 18:20:50
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA
|
Thu Mar 31 12:11:04 2011, Manfred Valentan, Micron Baby, DUT4, source run, post irrad, pre zupf, cal101, , 31.03.2011 12:09:36, 31.03.2011 12:17:52
|
DUT4
config file: micronbaby_single_irrrad_cal101.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA
|
Thu Mar 31 10:28:19 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal100, , 31.03.2011 10:24:59, 31.03.2011 10:33:15
|
DUT5
cal-file: micronbaby_single_irrad_cal100.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA
|
Sat Oct 9 12:00:55 2010, Christian Irmler, BELLE, cal, cal017, 83800, 09.10.2010 11:59:37,
|
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |
Fri Oct 8 23:05:03 2010, Markus Friedl, BELLE, cal, cal016, 83800, 08.10.2010 23:03:16,
|
Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
Bias connection of Origami repaired --> lower noise on p-side |
Fri Oct 8 17:26:36 2010, Markus Friedl, BELLE, cal, cal015, 83800, 08.10.2010 17:22:44,
|
Belle stack without Origami2
HV=11V I=32uA
beam on
2 suspicious APVs on n side of Micron due to burnt strip
trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |
Wed Oct 6 23:03:15 2010, Marko Dragicevic, BELLE, cal, cal014, 83800, 06.10.2010 23:01:56, 06.10.2010 23:34:07
|
Belle stack without Origami2
HV=80V I=227uA
beam on |
Wed Oct 6 11:03:59 2010, Marko Dragicevic, Micron Baby, cal, cal013, 83800, 06.10.2010 11:03:12,
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
Tue Oct 5 17:50:23 2010, Christian Irmler, ITE, cal, cal012, 83800, 05.10.2010 17:50:26, 05.10.2010 18:09:48
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
Mon Oct 4 20:16:19 2010, Christian Irmler, BELLE, cal, cal011, 83800, 04.10.2010 20:15:00,
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
HV connection of Origami 1 repaired |
|