ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
34
|
Wed Sep 29 14:03:55 2010 |
Markus Friedl | BELLE | cal | cal004 | 83800 | 29.09.2010 14:02:25 | 29.09.2010 14:45:05 |
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=100µA, beam off
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered |
37
|
Wed Sep 29 17:38:19 2010 |
Markus Friedl | Micron Baby | cal | cal005 | 83800 | 29.09.2010 17:36:38 | |
micron baby stack
HV=100V I=6.5uA
Beam off |
44
|
Thu Sep 30 15:06:28 2010 |
Markus Friedl | Micron Baby | cal | cal006 | 83800 | 30.09.2010 15:01:56 | |
micron baby: 4 DUTs - angle scan
HV=100V I=6.8uA
Beam off (turned on at ~8k events)
|
59
|
Sat Oct 2 17:27:14 2010 |
Thomas Bergauer | ITE | cal | cal007 | 83800 | 02.10.2010 17:11:18 | |
ITE: 2 DUTs
2 x SILC + 2 x ITE
HV=100V
Beam on
one short only per sensor |
Attachment 1: intcal_ITE10PAD_W7.png
|
|
Attachment 2: intcal_ITE10PAD_W9.png
|
|
62
|
Sun Oct 3 08:14:39 2010 |
Markus Friedl | ITE | cal | cal008 | 83800 | 03.10.2010 08:13:06 | |
6 x SILC + 2 x ITE
HV=100V
telescope position: 119
no beam (technical problem) |
64
|
Sun Oct 3 14:35:12 2010 |
Marko Dragicevic | CNM | cal | cal009 | 83800 | 03.10.2010 13:50:54 | |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
DUT outside of beam
calibration started after 1 hour warmup |
Attachment 1: cal009_cal_apv6.png
|
|
Attachment 2: cal009_cal_apv7.png
|
|
Attachment 3: slowcontrol_CNM_cal009.gif
|
|
66
|
Sun Oct 3 18:23:27 2010 |
Christian Irmler | Pt | cal | cal010 | 83800 | 03.10.2010 18:26:49 | |
pt modules angle scan
h01-Pt and h02-Pt
currents: h01=23.1µA h02=10.4µA
HV=200V
beam on
modules flushed with dry air
|
Attachment 1: slowcontrol_pt_cal010.gif
|
|
81
|
Mon Oct 4 20:16:19 2010 |
Christian Irmler | BELLE | cal | cal011 | 83800 | 04.10.2010 20:15:00 | |
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
HV connection of Origami 1 repaired |
87
|
Tue Oct 5 17:50:23 2010 |
Christian Irmler | ITE | cal | cal012 | 83800 | 05.10.2010 17:50:26 | 05.10.2010 18:09:48 |
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
90
|
Wed Oct 6 11:03:59 2010 |
Marko Dragicevic | Micron Baby | cal | cal013 | 83800 | 06.10.2010 11:03:12 | |
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
95
|
Wed Oct 6 23:03:15 2010 |
Marko Dragicevic | BELLE | cal | cal014 | 83800 | 06.10.2010 23:01:56 | 06.10.2010 23:34:07 |
Belle stack without Origami2
HV=80V I=227uA
beam on |
97
|
Fri Oct 8 17:26:36 2010 |
Markus Friedl | BELLE | cal | cal015 | 83800 | 08.10.2010 17:22:44 | |
Belle stack without Origami2
HV=11V I=32uA
beam on
2 suspicious APVs on n side of Micron due to burnt strip
trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |
100
|
Fri Oct 8 23:05:03 2010 |
Markus Friedl | BELLE | cal | cal016 | 83800 | 08.10.2010 23:03:16 | |
Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
Bias connection of Origami repaired --> lower noise on p-side |
104
|
Sat Oct 9 12:00:55 2010 |
Christian Irmler | BELLE | cal | cal017 | 83800 | 09.10.2010 11:59:37 | |
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |
112
|
Thu Mar 31 10:28:19 2011 |
Manfred Valentan | Micron Baby | DUT5, source run, post irrad, pre zupf | cal100 | | 31.03.2011 10:24:59 | 31.03.2011 10:33:15 |
DUT5
cal-file: micronbaby_single_irrad_cal100.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA
|
114
|
Thu Mar 31 12:11:04 2011 |
Manfred Valentan | Micron Baby | DUT4, source run, post irrad, pre zupf | cal101 | | 31.03.2011 12:09:36 | 31.03.2011 12:17:52 |
DUT4
config file: micronbaby_single_irrrad_cal101.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA
|
117
|
Mon Apr 11 18:25:35 2011 |
Manfred Valentan | Micron Baby | DUT5, source run, post irrad, pre zupf | cal104 | 83800 | 11.04.2011 18:12:38 | 11.04.2011 18:20:50 |
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA
|
119
|
Wed Apr 13 12:13:09 2011 |
Manfred Valentan | Micron Baby | DUT5, source run, post irrad, post zupf ** DO NOT USE ** | cal105 | 83800 | 13.04.2011 12:02:41 | 13.04.2011 12:10:55 |
DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA
data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!! |
122
|
Wed May 11 16:28:20 2011 |
Manfred Valentan | Micron Baby | DUT5, source run, post irrad, post zupf | cal106 | 100k | 11.05.2011 16:00 | 11.05.2011 16:25 |
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA
DAQ modified so that only strips marked as good are considered when calculating the common mode correction. |
123
|
Tue May 17 13:02:34 2011 |
Manfred Valentan | Micron Baby | TRK1, source run, unirrad, prezupf | cal107 | 83800 | 17.05.2011 12:20 | 17.05.2011 12:35 |
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA |