Wed Sep 29 14:03:55 2010, Markus Friedl, BELLE, cal, cal004, 83800, 29.09.2010 14:02:25, 29.09.2010 14:45:05
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=100µA, beam off
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered |
Wed Sep 29 17:38:19 2010, Markus Friedl, Micron Baby, cal, cal005, 83800, 29.09.2010 17:36:38,
|
micron baby stack
HV=100V I=6.5uA
Beam off |
Thu Sep 30 15:06:28 2010, Markus Friedl, Micron Baby, cal, cal006, 83800, 30.09.2010 15:01:56,
|
micron baby: 4 DUTs - angle scan
HV=100V I=6.8uA
Beam off (turned on at ~8k events)
|
Sat Oct 2 17:27:14 2010, Thomas Bergauer, ITE, cal, cal007, 83800, 02.10.2010 17:11:18 ,
|
ITE: 2 DUTs
2 x SILC + 2 x ITE
HV=100V
Beam on
one short only per sensor |
Sun Oct 3 08:14:39 2010, Markus Friedl, ITE, cal, cal008, 83800, 03.10.2010 08:13:06,
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 119
no beam (technical problem) |
Sun Oct 3 14:35:12 2010, Marko Dragicevic, CNM, cal, cal009, 83800, 03.10.2010 13:50:54,
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
DUT outside of beam
calibration started after 1 hour warmup |
Sun Oct 3 18:23:27 2010, Christian Irmler, Pt, cal, cal010, 83800, 03.10.2010 18:26:49 ,
|
pt modules angle scan
h01-Pt and h02-Pt
currents: h01=23.1µA h02=10.4µA
HV=200V
beam on
modules flushed with dry air
|
Mon Oct 4 20:16:19 2010, Christian Irmler, BELLE, cal, cal011, 83800, 04.10.2010 20:15:00,
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
HV connection of Origami 1 repaired |
Tue Oct 5 17:50:23 2010, Christian Irmler, ITE, cal, cal012, 83800, 05.10.2010 17:50:26, 05.10.2010 18:09:48
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
Wed Oct 6 11:03:59 2010, Marko Dragicevic, Micron Baby, cal, cal013, 83800, 06.10.2010 11:03:12,
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
Wed Oct 6 23:03:15 2010, Marko Dragicevic, BELLE, cal, cal014, 83800, 06.10.2010 23:01:56, 06.10.2010 23:34:07
|
Belle stack without Origami2
HV=80V I=227uA
beam on |
Fri Oct 8 17:26:36 2010, Markus Friedl, BELLE, cal, cal015, 83800, 08.10.2010 17:22:44,
|
Belle stack without Origami2
HV=11V I=32uA
beam on
2 suspicious APVs on n side of Micron due to burnt strip
trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |
Fri Oct 8 23:05:03 2010, Markus Friedl, BELLE, cal, cal016, 83800, 08.10.2010 23:03:16,
|
Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
Bias connection of Origami repaired --> lower noise on p-side |
Sat Oct 9 12:00:55 2010, Christian Irmler, BELLE, cal, cal017, 83800, 09.10.2010 11:59:37,
|
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |
Thu Mar 31 10:28:19 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal100, , 31.03.2011 10:24:59, 31.03.2011 10:33:15
|
DUT5
cal-file: micronbaby_single_irrad_cal100.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA
|
Thu Mar 31 12:11:04 2011, Manfred Valentan, Micron Baby, DUT4, source run, post irrad, pre zupf, cal101, , 31.03.2011 12:09:36, 31.03.2011 12:17:52
|
DUT4
config file: micronbaby_single_irrrad_cal101.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA
|
Mon Apr 11 18:25:35 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal104, 83800, 11.04.2011 18:12:38, 11.04.2011 18:20:50
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA
|
Wed Apr 13 12:13:09 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf ** DO NOT USE **, cal105, 83800, 13.04.2011 12:02:41, 13.04.2011 12:10:55
|
DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA
data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!! |
Wed May 11 16:28:20 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf, cal106, 100k, 11.05.2011 16:00, 11.05.2011 16:25
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA
DAQ modified so that only strips marked as good are considered when calculating the common mode correction. |
Tue May 17 13:02:34 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, cal107, 83800, 17.05.2011 12:20, 17.05.2011 12:35
|
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA |
|