Testbeams at MedAustron in 2025, Page 8 of 13
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- DUT --
common
DSSD-Tracker
RD50-MPW4
TJ-Monopix2
TOF-Cal GSI
RaMon
TOF-Cal GSI \(TRB)+DOGMA setup\(diamond+LGAD)+RaMon
Sandwich-iCT setup\(GSI)+RaMon
-- Beam Energy --
800 MeV
252.7 MeV
194.3 MeV
175.3 MeV
145.4 MeV
100.4 MeV
83 MeV
62.4 MeV
115.7MeV
205.2 MeV/u
177.8 MeV/u
147.2 MeV/u
124.4 MeV/u
97.2MeV/u
73.2 MeV/u
63.3 MeV/u
402MeV/u
247 Entries
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
...
11
,
12
,
13
Next
All
ID
Date
Author
Subject
Run Number
DUT
Beam Energy
Rate Setting
Particle Type
Data
t-Start
t-Stop
Duration_min
Frontend
Phantom
Phantom thickness
Text
244
Sat Sep 20 21:12:30 2025
elog_producer
Caribou 1.5
1042
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
20.09.2025 21:11:57
20.09.2025 21:12:41
0
Normal
automatic log for run 1042
Comment:
DMA debugging
245
Sat Sep 20 21:19:04 2025
elog_producer
Caribou 1.5
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
Normal
DMA debugging
not waiting for IOC flag
frame rate UDP vs. DMA similar now
246
Sat Sep 20 21:19:29 2025
elog_producer
Caribou 1.5
1043
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
20.09.2025 21:18:09
20.09.2025 21:19:40
1
Normal
automatic log for run 1043
Comment:
DMA debugging
247
Sat Sep 20 21:23:52 2025
elog_producer
Caribou 1.5
1044
RD50-MPW4
800 MeV
Low Flux High
Proton
Unknown
20.09.2025 21:23:44
20.09.2025 21:24:03
0
Normal
automatic log for run 1044
Comment:
DMA debugging
47
Sat Mar 15 04:20:39 2025
elog-producer
energy scans
232
TJ-Monopix2
83 MeV
Low Flux Very Low
Proton
Good
15.03.2025 04:13:51
15.03.2025 04:21:05
7
HV
None
automatic log for run 232
Comment:
61
Sat Mar 15 08:52:52 2025
RD50 Generic User
Alignment Run 800MeV
2
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux Medium
Proton
Good
08:22
9:40
78
RaMon Rate 400kHz
front sensors 200mu: ~10-20kHz
pro Streifen
62
Sat Mar 15 08:58:26 2025
RD50 Generic User
Alignment Run 800MeV
1
Sandwich-iCT setup(GSI)+RaMon
800 MeV
Low Flux Low
Proton
Good
07:40
08:20
40
RaMon Rate not measured
front sensors 200mu: ~40-60Hz pro
Streifen
64
Sat Mar 15 10:07:28 2025
RD50 Generic User
Alignment Run 252MeV
4
Sandwich-iCT setup(GSI)+RaMon
252.7 MeV
Low Flux Medium
Proton
Good
10:07
11:43
96
RaMon Rate 1MHz
front sensors 200mu: ~10-25kHz
pro Streifen
65
Sat Mar 15 11:46:28 2025
RD50 Generic User
Slab Measurement 145MeV
5
Sandwich-iCT setup(GSI)+RaMon
145.4 MeV
Low Flux Medium
Proton
Good
11:48
13:13
85
RaMon Rate 600kHz
front sensors 200mu: ~1kHz pro
Streifen
66
Sat Mar 15 13:15:25 2025
RD50 Generic User
Slab Measurement 205MeV
6
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
13:27
14:49
82
RaMon Rate 1.3 MHz
Comments:
We entered the room and connected
67
Sat Mar 15 15:02:39 2025
RD50 Generic User
Rate testing
7
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
15:04
15:25
21
RaMon Rate 4.5MHz
Comments:
From File 7 until 21 optional false,
69
Sat Mar 15 16:50:39 2025
RD50 Generic User
Slab Test Water 1cm
9
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux Medium
Helium
Good
16:35
17:23
48
Plastic Water Slabs
1cm
RaMon Rate: 1.3MHz
73
Sat Mar 15 21:25:18 2025
RD50 Generic User
Slab Test Water 5cm
14
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
21:26
21:50
24
Plastic Water Slabs
5cm
RaMon rate: 4.5MHz
74
Sat Mar 15 21:29:28 2025
RD50 Generic User
Slab and rate testing (with Michael)
13
Sandwich-iCT setup(GSI)+RaMon
205.2 MeV/u
Low Flux High
Helium
Good
20:44
21:22
38
Plastic Water Slabs
4cm
totzeit optimieren und deadtime finden
hex wert mal 10ns deadtime
13 ab file 10 besat effort
75
Sat Jun 21 14:30:29 2025
Julia Müllner
800MeV systemtest
1
TOF-Cal GSI
800 MeV
Low Flux High
Proton
Good
14:45
15:42
57
first spills were done with low flux medium,
changed to high at 14:49
again changed to medium at 14:55
76
Sat Jun 21 15:43:47 2025
Julia Müllner
800MeV systemtest
2
TOF-Cal GSI
800 MeV
Low Flux High
Proton
Good
16:02
16:29
27
Threshold set to 1000
Factor 4 chosen for future runs,
80 GB in total recorded in this run
78
Sat Jun 21 17:01:05 2025
Julia Müllner
97.2 MeV systemtest
4
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
16:58
17:11
13
Data was good, we have to shuft the setup
in x direction and slightly down. Enter room
request 17:12.
79
Sat Jun 21 17:13:34 2025
Julia Müllner
97.2 MeV systemtest
5
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:31
17:54
23
Threshold set to 3000
moved Ripple filters back in
100GB data collected
80
Sat Jun 21 17:54:27 2025
Julia Müllner
97.2 MeV systemtest
6
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
17:56
18:04
8
Threshold set to 4000
40GB data collected
81
Sat Jun 21 18:05:21 2025
Julia Müllner
97.2 MeV systemtest
7
TOF-Cal GSI
97.2MeV/u
Low Flux High
Helium
Good
18:06
18:21
15
Threshold set to 2000
50GB data collected