Entry  Sat Mar 15 16:50:39 2025, RD50 Generic User, Slab Test Water 1cm, 9, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 16:35, 17:23, 48, , Plastic Water Slabs, 1cm 

RaMon Rate: 1.3MHz

Entry  Sat Mar 15 17:30:18 2025, RD50 Generic User, Slab Test Water 2cm, 10, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 17:30, 18:24, 54, , Plastic Water Slabs, 2cm 

RaMon Rate 1.5 MHz

Entry  Sat Mar 15 18:37:36 2025, RD50 Generic User, Slab Test Water 3cm, 11, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 18:41, 19:28, 47, , Plastic Water Slabs, 3cm 

RaMon Rate 1.5MHz

Entry  Sat Mar 15 19:37:42 2025, RD50 Generic User, Slab Test Water 4cm, 12, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, , 19:39, 20:41, 62, , Plastic Water Slabs, 4cm 

RaMon Rate 1.4MHz

Entry  Sat Mar 15 01:29:25 2025, elog-producer, Fast RO Test, 215, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 15.03.2025 01:26:13, 15.03.2025 01:29:51, 3, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 215
Comment:
Lower rates then Very low settings, so just a quick run here
Fast RO for Monopix:

Delay = 2
rd_frz_delay = 2

LOAD_CONF=10
FREEZE_STOP_CONF=11
STOP_CONF=10
Entry  Sat Mar 15 02:15:34 2025, elog-producer, Fast RO Test, 221, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 15.03.2025 02:02:15, 15.03.2025 02:16:00, 13, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 221
Comment:
Entry  Sat Mar 15 02:56:07 2025, elog-producer, energy scans, 225, TJ-Monopix2, 252.7 MeV, Low Flux Low, Proton, Unknown, , , , HV, None,  
8b10b W02R01, 1 MHz rate (low flux low)
Entry  Sat Mar 15 08:58:26 2025, RD50 Generic User, Alignment Run 800MeV, 1, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux Low, Proton, Good, 07:40, 08:20, 40, , ,  

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

Entry  Sat Mar 15 04:39:13 2025, elog-producer, test rate limits, 236, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Unknown, 15.03.2025 04:38:04, 15.03.2025 04:39:39, 1, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 236
Comment:
Increase csinti thr to -0.2
Entry  Sat Mar 15 04:42:48 2025, elog-producer, test rate limits, 237, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Unknown, 15.03.2025 04:40:28, 15.03.2025 04:43:14, 2, HV, None,  tjmonopix2.initjmonopix2.conf
automatic log for run 237
Comment:
Increase csinti thr to -0.3
Entry  Sat Mar 15 09:51:23 2025, RD50 Generic User, Alignment Run 800MeV, 3, Sandwich-iCT setup(GSI)+RaMon, 800 MeV, Low Flux High, Proton, Unknown, 9:44, 10:03, 19, , ,  

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

Entry  Sat Mar 15 15:02:39 2025, RD50 Generic User, Rate testing, 7, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:04, 15:25, 21, , ,  

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

Entry  Sat Mar 15 21:25:18 2025, RD50 Generic User, Slab Test Water 5cm, 14, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 21:26, 21:50, 24, , Plastic Water Slabs, 5cm 

RaMon rate: 4.5MHz

Entry  Sat Mar 15 21:29:28 2025, RD50 Generic User, Slab and rate testing (with Michael), 13, Sandwich-iCT setup(GSI)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 20:44, 21:22, 38, , Plastic Water Slabs, 4cm 

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600