Entry  Sat Dec 13 14:18:49 2025, elog_producer, energy calibration, 17, Sandwich-iCT setup(GSI)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 13.12.2025 14:02:30, 13.12.2025 14:19:14, 16, Normal, None,  ramon.conf
automatic log for run 17
Comment:
calibration run 63.3 MeV
Entry  Sat Aug 16 23:44:00 2025, Maximilian Babeluk, CASTID - Summary, , TJ-Monopix2, 800 MeV, , Proton, , , , , , ,  

Summary for the CASTID shift RO Aug 16, 2025

We measured four TJ-Monopix2 DUTS with HV/HVC frontends using AIDA mode in a stacked telescope configuration. We used 800MeV protons at low flux settings from very low to high.

 

We took two high statistics runs on each of the 4 rates. Then we repeated the measurements at medium and high settings for following readout speeds (40 is the default): 30, 20, 10, 2 (minimum).

At increased readout speed, we shoudl be able to recover (part) of the efficiency drop at increased rates.

- Occasionally (maybe a few times an hour but in clusters) we got 8b/10b errors. If so, they all came from the W02R01 DUT using BDAQ board #063/50 and the TLU adapter 1. This is the main source of having 'crap' data

- About 3 times during the test beam, one of the chips (each time a different one) stopped sending data which was possible to recover with a power cycle.

 

Entry  Sat Dec 6 20:15:47 2025, Felix Ulrich-Pur, systemtest carbon, 17, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, , , Carbon, Good, 20:16, 20:29, 13, , None,  

400.1MeV, Degrader 10