Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 2 of 19  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thicknessdown
  275   Sun Dec 7 00:47:00 2025 Felix Ulrich-PurRW3 slab29TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood00:471:0417 RW31cm

45Mb/s Events and 1Mb/s rejected

PreTriggerWindow 640ns and PostTriggerWindow 85ns

  276   Sun Dec 7 01:05:08 2025 Felix Ulrich-PurRW3 slab30TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood1:061:148 RW31cm

80Mb/s Events and 20Mb/s rejected

PreTriggerWindow 3360ns and PostTriggerWindow 640ns

  340   Sat Dec 13 12:26:16 2025 elog_producermixed beam9Sandwich-iCT setup(GSI)+RaMon200 MeV/ureduced_mixed_beamMixed Beam (He+C)Good13.12.2025 11:47:1913.12.2025 12:26:4139NormalMixed Beam QA phantom (ICs)17cm
automatic log for run 9
Comment:
xx% He
mixed beam QA test run
  358   Sat Dec 13 19:35:03 2025 elog_producerenergy calibration27Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:18:3313.12.2025 19:35:2916NormalRW3 Plate12cm+3mm
automatic log for run 27
Comment:
2x ionization chambers
identifier g
mki: 290
  359   Sat Dec 13 19:47:31 2025 elog_producerenergy calibration28Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:42:0013.12.2025 19:47:575NormalRW3 Plate12cm+3mm
automatic log for run 28
Comment:
2x ionization chambers
identifier h
mki: 310
(ramon start delayed Frown)
  360   Sat Dec 13 20:04:41 2025 elog_producerenergy calibration29Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 19:49:0113.12.2025 20:05:0716NormalRW3 Plate12cm+3mm
automatic log for run 29
Comment:
2x ionization chambers
C only
identifier i
mki: 430
  361   Sat Dec 13 20:24:58 2025 elog_producerenergy calibration30Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 20:10:4313.12.2025 20:25:2414NormalRW3 Plate12cm+3mm
automatic log for run 30
Comment:
2x ionization chambers
0.5mm Kapton
identifier j
mki: 310
  356   Sat Dec 13 18:47:46 2025 elog_producerenergy calibration25Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:28:2213.12.2025 18:48:1219NormalRW3 Plate12cm+2mm
automatic log for run 25
Comment:
2x ionization chambers
identifier e
mki: 310
  357   Sat Dec 13 19:11:30 2025 elog_producerenergy calibration26Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:50:2113.12.2025 19:11:5621NormalRW3 Plate12cm+2mm
automatic log for run 26
Comment:
2x ionization chambers
identifier f
mki: 290
  354   Sat Dec 13 18:01:55 2025 elog_producerenergy calibration23Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 17:43:0713.12.2025 18:02:2119NormalRW3 Plate12cm
automatic log for run 23
Comment:
2x ionization chambers
identifier c
  355   Sat Dec 13 18:22:46 2025 elog_producerenergy calibration24Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 18:04:2513.12.2025 18:23:1118NormalRW3 Plate12cm
automatic log for run 24
Comment:
2x ionization chambers
identifier d
  350   Sat Dec 13 16:00:08 2025 elog_producerenergy calibration19Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 15:02:1513.12.2025 16:00:3458NormalRW3 Plate11cm
automatic log for run 19
Comment:
2x ionization chambers
new threshold scan
1 spill 400MeV
downtime
  351   Sat Dec 13 16:26:02 2025 elog_producerenergy calibration20Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:13:1013.12.2025 16:26:2813NormalRW3 Plate10cm
automatic log for run 20
Comment:
2x ionization chambers
start only He without dogma
Starts with only C (16:24)
  352   Sat Dec 13 16:54:13 2025 elog_producerenergy calibration21Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:27:3413.12.2025 16:54:3927NormalRW3 Plate10cm
automatic log for run 21
Comment:
2x ionization chambers
same C setting now with He
identifier a
powercycle TDCs (16:43)
  353   Sat Dec 13 17:26:16 2025 elog_producerenergy calibration22Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Good13.12.2025 16:57:5913.12.2025 17:26:4128NormalRW3 Plate10cm
automatic log for run 22
Comment:
2x ionization chambers
identifier b
  94   Sat Jun 21 22:04:52 2025 Julia Müllner124.4 MeV w slab20TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood22:0922:2112 PTW Slabs0.5cm

Recorded data: 20GB

  280   Sun Dec 7 02:33:26 2025 RD50 Generic UserRW3 slab34TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood2:342:58  RW30.5cm

48Mb/s Events and 2Mb/s rejected

PreTriggerWindow 640ns and PostTriggerWindow 85ns

troubles till 02:48 (dogma powercycle)

  281   Sun Dec 7 04:27:09 2025 RD50 Generic UserMaus135TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood4:294:356 Mouse0.5cm

angle = 0

x/y=-39/-27

PreTriggerWindow 640ns and PostTriggerWindow 85n

  95   Sat Jun 21 22:21:56 2025 Julia Müllner124.4 MeV w slab21TOF-Cal GSI124.4 MeV/uLow Flux HighHeliumGood22:2622:359 PTW Slabs0.2cm

auf hades p81 sind alle files ab 008 einschließend sind keine daten sonder kalibrationspulse

  1   Wed Mar 12 09:29:08 2025 tb-crewvalidating setup TJ-Monopix2800 MeVLow Flux Very LowProtonUnknown   HVNone 
1st test
ELOG V3.1.5-fc6679b