Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 13 of 19  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantomdown Phantom thickness
  322   Sun Dec 7 07:45:04 2025 RD50 Generic UserMaus376TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood7:457:472 Mouse 

angle = 180

x/y=-27/-59.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  323   Sun Dec 7 07:48:18 2025 RD50 Generic UserMaus377TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood7:497:523 Mouse 

angle = 180

x/y=-24/-59.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  324   Sun Dec 7 07:52:12 2025 RD50 Generic UserMaus378TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood7:537:552 Mouse 

angle = 180

x/y=-24/-56.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  325   Sun Dec 7 07:55:52 2025 RD50 Generic UserMaus380TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:008:022 Mouse 

angle = 180

x/y=-24/-50.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  326   Sun Dec 7 08:03:04 2025 RD50 Generic UserMaus381TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:028:064 Mouse 

angle = 180

x/y=-21/-50.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  327   Sun Dec 7 08:06:53 2025 RD50 Generic UserMaus382TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:078:147 Mouse 

angle = 180

x/y=-21/-47.5

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  328   Sun Dec 7 08:15:21 2025 RD50 Generic UserMaus383TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood    Mouse 

angle = 180

x/y=-21/-44.5 (falsche Richtung :( )

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  329   Sun Dec 7 08:18:05 2025 RD50 Generic UserMaus384TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:188:213 Mouse 

angle = 180

x/y=-21/-53.5 

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  330   Sun Dec 7 08:21:19 2025 RD50 Generic UserMaus385TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:218:243 Mouse 

angle = 180

x/y=-21/-56.5 

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  331   Sun Dec 7 08:24:32 2025 RD50 Generic UserMaus386TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood8:248:273 Mouse 

angle = 180

x/y=-21/-59.5 

rate:6 10e6

PreTriggerWindow 2.915us and PostTriggerWindow 85ns

  340   Sat Dec 13 12:26:16 2025 elog_producermixed beam9Sandwich-iCT setup(GSI)+RaMon200 MeV/ureduced_mixed_beamMixed Beam (He+C)Good13.12.2025 11:47:1913.12.2025 12:26:4139NormalMixed Beam QA phantom (ICs)17cm
automatic log for run 9
Comment:
xx% He
mixed beam QA test run
Attachment 1: ramon.conf
# example config file: Ex0.conf
[RunControl]
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
# from the base RunControl.cc
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
# Steer which values to display in the GUI: producerName and displayed value are seperated by a ",". 
ADDITIONAL_DISPLAY_NUMBERS = "log,_SERVER"


[Producer.aida_tlu]
## GENERAL PARAMETERS
verbose= 1
skipconf= 0
confid= 20201311
delayStart= 200  

## HDMI CONFIGURATION
#  4-bits to determine direction of HDMI pins
HDMI1_set= 0x7 #1= output (driven by TLU), 0 = input. bit 0=CONT, 1=SPARE, 2=TRIG, 3=BUSY for eudet, Busy needs to be 0. (0b0111 = 0x7)
HDMI2_set= 0x7
HDMI3_set= 0x7
HDMI4_set= 0x7
#  Clock source (0= no clock, 1= Si5345, 2= FPGA)
HDMI1_clk = 1
HDMI2_clk = 1
HDMI3_clk = 1
HDMI4_clk = 1
#  Enable/Disable clock on differential LEMO
LEMOclk = 0

## PMT POWER CONFIGURATION
PMT1_V= 0.8 #0.6363 #Szinti 4x4cm
PMT2_V= 0.8 #0.6363 #Szinti 4x4cm
PMT3_V= 0.8
PMT4_V= 0.8

## TRIGGER CONFIGURATION
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008 # 0x00000008 Koinzidenz 1+2 ; 0x00000040 Koinzidenz 2+3
in0_STR = 0	# 0 
in0_DEL = 0	# 18
in1_STR = 0	# 0
in1_DEL = 0	# 18
in2_STR = 0	# 0
in2_DEL = 0 	# 0
in3_STR = 0
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0 #streches pulse from 6.25ns (at 0) to 12.5ns
in5_DEL = 0
# Generate internal triggers (in Hz, 0= no triggers)
InternalTriggerFreq= 0 #4000 #00

## DISCRIMINATOR THRESHOLDS
DACThreshold0 = -0.025 #-0.025 #-0.012
DACThreshold1 = -0.025 #-0.025 #-0.012
DACThreshold2 = -0.012
DACThreshold3 = -0.12
DACThreshold4 = -0.12 #-0.0066
DACThreshold5 = -0.12

## DUT CONFIGURATION
 # DUTMask Which DUTs are on
#DUTMask= 0x3 #6 bit 0= DUT1, bit 1= DUT2, bit 2= DUT3, bit 3= DUT4
#DUTMask= 0x6

 # DUTMaskMode Define AIDA (11) or EUDET (00) mode (2 bits per DUT)
DUTMaskMode= 0x30 #0x00

 # In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
DUTMaskModeModifier= 0x30 #0x30 #0xC0 PS: Check what this does! 0x0 würde ich hier eingeben

 # Ignore the BUSY signal for a DUT (0xF)
DUTIgnoreBusy= 0xF #ignores triggers
DUTIgnoreShutterVeto= 0x0
EnableRecordData = 1


# EnableShutterMode: 0x0. If 1, shutter mode is enabled. If 0, shutter mode is disabled.
EnableShutterMode= 0x0
# Define which input is used for shutter source [0 - 5]
ShutterSource = 5
# 32-bit counter of clocks. Set to 0 to not use internal shutter generator.
InternalShutterInterval = 0
# 32-bit counter of clocks
ShutterOnTime = 0 #start of shutter after trigger
# 32-bit counter of clocks
ShutterVetoOffTime = 0 #time after input-trigger, until first trigger is sent to output
# 32-bit counter of clocks
ShutterOffTime = 200000000 #end of shutter after trigger #200000000 = 5s (multiples of 25ns)

## DATA COLLECTOR
EUDAQ_DC= tlu_dc

## TLU MONITOR PARAMETER
FileComment="LU_MedAustron"
PlotWindowSizeinns=40e9
MinSpillTimeOnins=4.5
MinSpilldownTimeins=0.5
ThreshEvBegin=1
ThreshEvEnd=1
ThreshPartBegin=1
ThreshPartEnd=1



[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# nothing

[Producer.elog1]


  363   Sat Dec 13 21:35:30 2025 elog_producerKopf Phantom32Sandwich-iCT setup(GSI)+RaMon200 MeV/uNominalMixed Beam (He+C)Crap13.12.2025 21:26:4513.12.2025 21:35:569NormalKopf 
automatic log for run 32
Comment:
sinus cavity spot 5mm down
identifier ba
mki: 310
sensor 4 seems to be dead, measure without it
enabling preamps for sensor 1+2 is beneficial for data (21:35)
Attachment 1: ramon.conf
# example config file: Ex0.conf
[RunControl]
#pCT_STOP_RUN_AFTER_N_SECONDS = 3000000
# from the base RunControl.cc
#EUDAQ_CTRL_PRODUCER_LAST_START = my_pd0
#EUDAQ_CTRL_PRODUCER_FIRST_STOP = my_pd0
# Steer which values to display in the GUI: producerName and displayed value are seperated by a ",". 
ADDITIONAL_DISPLAY_NUMBERS = "log,_SERVER"


[Producer.aida_tlu]
## GENERAL PARAMETERS
verbose= 1
skipconf= 0
confid= 20201311
delayStart= 200  

## HDMI CONFIGURATION
#  4-bits to determine direction of HDMI pins
HDMI1_set= 0x7 #1= output (driven by TLU), 0 = input. bit 0=CONT, 1=SPARE, 2=TRIG, 3=BUSY for eudet, Busy needs to be 0. (0b0111 = 0x7)
HDMI2_set= 0x7
HDMI3_set= 0x7
HDMI4_set= 0x7
#  Clock source (0= no clock, 1= Si5345, 2= FPGA)
HDMI1_clk = 1
HDMI2_clk = 1
HDMI3_clk = 1
HDMI4_clk = 1
#  Enable/Disable clock on differential LEMO
LEMOclk = 0

## PMT POWER CONFIGURATION
PMT1_V= 0.8 #0.6363 #Szinti 4x4cm
PMT2_V= 0.8 #0.6363 #Szinti 4x4cm
PMT3_V= 0.8
PMT4_V= 0.8

## TRIGGER CONFIGURATION
trigMaskHi = 0x00000000
trigMaskLo = 0x00000008 # 0x00000008 Koinzidenz 1+2 ; 0x00000040 Koinzidenz 2+3
in0_STR = 0	# 0 
in0_DEL = 0	# 18
in1_STR = 0	# 0
in1_DEL = 0	# 18
in2_STR = 0	# 0
in2_DEL = 0 	# 0
in3_STR = 0
in3_DEL = 0
in4_STR = 0
in4_DEL = 0
in5_STR = 0 #streches pulse from 6.25ns (at 0) to 12.5ns
in5_DEL = 0
# Generate internal triggers (in Hz, 0= no triggers)
InternalTriggerFreq= 0 #4000 #00

## DISCRIMINATOR THRESHOLDS
DACThreshold0 = -0.025 #-0.025 #-0.012
DACThreshold1 = -0.025 #-0.025 #-0.012
DACThreshold2 = -0.012
DACThreshold3 = -0.12
DACThreshold4 = -0.12 #-0.0066
DACThreshold5 = -0.12

## DUT CONFIGURATION
 # DUTMask Which DUTs are on
#DUTMask= 0x3 #6 bit 0= DUT1, bit 1= DUT2, bit 2= DUT3, bit 3= DUT4
#DUTMask= 0x6

 # DUTMaskMode Define AIDA (11) or EUDET (00) mode (2 bits per DUT)
DUTMaskMode= 0x30 #0x00

 # In EUDET mode: 0 = standard trigger/busy mode, 1 = raising BUSY outside handshake vetoes triggers (2 bits per DUT, 0x3= DUT 4! -backwards!)
DUTMaskModeModifier= 0x30 #0x30 #0xC0 PS: Check what this does! 0x0 würde ich hier eingeben

 # Ignore the BUSY signal for a DUT (0xF)
DUTIgnoreBusy= 0xF #ignores triggers
DUTIgnoreShutterVeto= 0x0
EnableRecordData = 1


# EnableShutterMode: 0x0. If 1, shutter mode is enabled. If 0, shutter mode is disabled.
EnableShutterMode= 0x0
# Define which input is used for shutter source [0 - 5]
ShutterSource = 5
# 32-bit counter of clocks. Set to 0 to not use internal shutter generator.
InternalShutterInterval = 0
# 32-bit counter of clocks
ShutterOnTime = 0 #start of shutter after trigger
# 32-bit counter of clocks
ShutterVetoOffTime = 0 #time after input-trigger, until first trigger is sent to output
# 32-bit counter of clocks
ShutterOffTime = 200000000 #end of shutter after trigger #200000000 = 5s (multiples of 25ns)

## DATA COLLECTOR
EUDAQ_DC= tlu_dc

## TLU MONITOR PARAMETER
FileComment="LU_MedAustron"
PlotWindowSizeinns=40e9
MinSpillTimeOnins=4.5
MinSpilldownTimeins=0.5
ThreshEvBegin=1
ThreshEvEnd=1
ThreshPartBegin=1
ThreshPartEnd=1



[LogCollector.log]
# Currently, all LogCollectors have a hardcoded runtime name: log
# nothing

[Producer.elog1]


  61   Sat Mar 15 08:52:52 2025 RD50 Generic UserAlignment Run 800MeV2Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux MediumProtonGood08:229:4078   

RaMon Rate 400kHz

front sensors 200mu: ~10-20kHz pro Streifen

Comments:

In between run, sensors were shifted by 2mm to the left (left and right in online DAQ is mirrored)

 

  62   Sat Mar 15 08:58:26 2025 RD50 Generic UserAlignment Run 800MeV1Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux LowProtonGood07:4008:2040   

RaMon Rate not measured

front sensors 200mu: ~40-60Hz pro Streifen

Comments:

stopped run due to too low rate

 

  63   Sat Mar 15 09:51:23 2025 RD50 Generic UserAlignment Run 800MeV3Sandwich-iCT setup(GSI)+RaMon800 MeVLow Flux HighProtonUnknown9:4410:0319   

RaMon Rate 2MHz

front sensors 200mu: ~50-100kHz pro Streifen

Comments:

Factor 10 lost more data than measured

 

  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  65   Sat Mar 15 11:46:28 2025 RD50 Generic UserSlab Measurement 145MeV5Sandwich-iCT setup(GSI)+RaMon145.4 MeVLow Flux MediumProtonGood11:4813:1385   

RaMon Rate 600kHz

front sensors 200mu: ~1kHz pro Streifen

Comments:

change of the trigger settings inbetween, we saw inefficency on all detectors

  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  68   Sat Mar 15 15:26:08 2025 RD50 Generic UserRate testing8Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 15:3116:3059   

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey