ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  256   Sat Dec 6 17:24:05 2025 Felix Ulrich-Pur402MeV/u systemtest9TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/uLow Flux HighHeliumGood17:2417:4521 None 

17:43: eventbuilder restart since lots of rejected triggers 

  257   Sat Dec 6 17:45:43 2025 Felix Ulrich-Pur402MeV/u systemtest10TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/uLow Flux HighHeliumGood17:4718:0821 None 

threshold = 2000

  264   Sat Dec 6 20:29:53 2025 Felix Ulrich-Pur402MeV/u systemtest18TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/uLow Flux HighHeliumGood20:5021:1929 None 

2us TriggerWindow insgesamt: 640ns PostTriggerWindow und 1360 PreTriggerWindow, max 60Mb/s Events und 25Mb/s rejected pro Eventbuilder

  265   Sat Dec 6 21:20:03 2025 Felix Ulrich-Pur402MeV/u systemtest19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/uLow Flux HighHeliumGood21:2121:3716 None 

PreTriggerWindow 640ns and PostTriggerWindow 85ns

Max 70Mb/s and Droprate 6 Mb/s

  266   Sat Dec 6 21:38:02 2025 Felix Ulrich-Pur402MeV/u systemtest20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon402MeV/uLow Flux HighHeliumGood21:4122:0019 None 

PreTriggerWindow 3360ns and PostTriggerWindow 640ns 

Max 100Mb/s Events and 50Mb/s rejected

  341   Sat Dec 13 12:50:47 2025 elog_produceralignment10Sandwich-iCT setup(GSI)+RaMon402MeV/uLow Flux HighHeliumGood13.12.2025 12:42:4113.12.2025 12:51:128NormalNone 
automatic log for run 10
Comment:
alignment run
  38   Sat Mar 15 02:46:47 2025 elog-producerenergy scans TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
sticking with fast RO settings
  39   Sat Mar 15 02:53:18 2025 elog-producerenergy scans224TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown15.03.2025 02:49:4415.03.2025 02:53:443HVNone 
automatic log for run 224
Comment:
  40   Sat Mar 15 02:56:07 2025 elog-producerenergy scans225TJ-Monopix2252.7 MeVLow Flux LowProtonUnknown   HVNone 
8b10b W02R01, 1 MHz rate (low flux low)
  41   Sat Mar 15 03:14:22 2025 elog-producerenergy scans226TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 226
  42   Sat Mar 15 03:18:15 2025 elog-producerenergy scans227TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown15.03.2025 03:16:5215.03.2025 03:18:411HVNone 
automatic log for run 227
Comment:
  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  68   Sat Mar 15 15:26:08 2025 RD50 Generic UserRate testing8Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 15:3116:3059   

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cm

RaMon Rate 1.5 MHz

  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cm

RaMon Rate 1.5MHz

  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cm

RaMon Rate 1.4MHz

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz