Run nr. 12 wasn't recorded.
new calib from this run on
3360ns PreTriggerWindow and 640ns PostTriggerWindow
Had to restart eventbuilder at 19:39 due to high rejected rate
60Mb/s Events and 10-15Mb/s rejected
PreTriggerWindow: 640ns and PostTriggerWindow: 3.36µs
25Mb/s Events and 25Mb/s rejected
40Mb/s Events and 4 Mb/s rejected
PreTriggerWindow: 1360ns and PostTriggerWindow: 640ns
new callibration was done, dimanond detector connected to readout
Threshold = 4000
thresholds were too low -> run was canceled
Threshold change from 50 to 500
10GB collected
20 Mb/s Events and max 50 kB/s rejected
PreTriggerWindow 640ns and PostTriggerWindow 85ns
15 Mb/s Events and 30kb/s rejected
rejected roughly 10-20%, 8MHz beam
rejected quite a lot of data later -> eventloader restarted
axis 1: 5
axis 2: 2
degrader 10, mouse is still inside
just to check if the beam was there
interupted to get inside the room
setup was moved, stopped to move setup again
threshold = 4000
Setup wurde verschoben: 5mm vorne nach links und hinten 4mm, in Beamrichtung
threshold = 2000
PreTriggerWindow 640ns und PostTriggerWindow 85ns