Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  Testbeams at MedAustron in 2025, Page 10 of 13  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  132   Sun Jun 22 05:16:32 2025 Julia Müllner402 MeV mouse58TOF-Cal GSI402MeV/uLow Flux HighCarbonGood5:296:0031   

axis 1: 5

axis 2: 2

degrader 10, mouse is still inside

  38   Sat Mar 15 02:46:47 2025 elog-producerenergy scans TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
sticking with fast RO settings
  39   Sat Mar 15 02:53:18 2025 elog-producerenergy scans224TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown15.03.2025 02:49:4415.03.2025 02:53:443HVNone 
automatic log for run 224
Comment:
  40   Sat Mar 15 02:56:07 2025 elog-producerenergy scans225TJ-Monopix2252.7 MeVLow Flux LowProtonUnknown   HVNone 
8b10b W02R01, 1 MHz rate (low flux low)
  41   Sat Mar 15 03:14:22 2025 elog-producerenergy scans226TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown   HVNone 
Run 226
  42   Sat Mar 15 03:18:15 2025 elog-producerenergy scans227TJ-Monopix2252.7 MeVLow Flux Very LowProtonUnknown15.03.2025 03:16:5215.03.2025 03:18:411HVNone 
automatic log for run 227
Comment:
  64   Sat Mar 15 10:07:28 2025 RD50 Generic UserAlignment Run 252MeV4Sandwich-iCT setup(GSI)+RaMon252.7 MeVLow Flux MediumProtonGood10:0711:4396   

RaMon Rate 1MHz

front sensors 200mu: ~10-25kHz pro Streifen

  66   Sat Mar 15 13:15:25 2025 RD50 Generic UserSlab Measurement 205MeV6Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood13:2714:4982   

RaMon Rate 1.3 MHz

Comments:

We entered the room and connected the second LAN Port to the ReadOut-PC. The Eventbuilder-parameter got changed.

  67   Sat Mar 15 15:02:39 2025 RD50 Generic UserRate testing7Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:0415:2521   

RaMon Rate 4.5MHz

Comments:

From File 7 until 21 optional false, and from 22 true (everything deleted)

  68   Sat Mar 15 15:26:08 2025 RD50 Generic UserRate testing8Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 15:3116:3059   

RaMon Rate: 1.3MHz

Comments:

Tested different evenbuilder settings which made things worse, probably switch is the bottleneck, changed rate settings inbetween, requires sergey

  69   Sat Mar 15 16:50:39 2025 RD50 Generic UserSlab Test Water 1cm9Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHeliumGood16:3517:2348 Plastic Water Slabs1cm

RaMon Rate: 1.3MHz

  70   Sat Mar 15 17:30:18 2025 RD50 Generic UserSlab Test Water 2cm10Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 17:3018:2454 Plastic Water Slabs2cm

RaMon Rate 1.5 MHz

  71   Sat Mar 15 18:37:36 2025 RD50 Generic UserSlab Test Water 3cm11Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 18:4119:2847 Plastic Water Slabs3cm

RaMon Rate 1.5MHz

  72   Sat Mar 15 19:37:42 2025 RD50 Generic UserSlab Test Water 4cm12Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux MediumHelium 19:3920:4162 Plastic Water Slabs4cm

RaMon Rate 1.4MHz

  73   Sat Mar 15 21:25:18 2025 RD50 Generic UserSlab Test Water 5cm14Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood21:2621:5024 Plastic Water Slabs5cm

RaMon rate: 4.5MHz

  74   Sat Mar 15 21:29:28 2025 RD50 Generic UserSlab and rate testing (with Michael)13Sandwich-iCT setup(GSI)+RaMon205.2 MeV/uLow Flux HighHeliumGood20:4421:2238 Plastic Water Slabs4cm

totzeit optimieren und deadtime finden

hex wert mal 10ns deadtime

13 ab file 10 besat effort
ab 52 wieder ohne best effort

600

  77   Sat Jun 21 16:30:44 2025 Julia Müllner205.2 MeV systemtest 3TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumUnknown16:3816:5719   

Threshold set to 5000

dead channels on last LGAD, changed trigger from LGAD 12 to LGAD 11

  88   Sat Jun 21 20:24:05 2025 Julia Müllner205.2 MeV systemtest 14TOF-Cal GSI205.2 MeV/uLow Flux HighHeliumGood20:2420:328   

last events already with 400MeV/u

  87   Sat Jun 21 20:15:25 2025 Julia Müllner177.8 MeV systemtest 13TOF-Cal GSI177.8 MeV/uLow Flux HighHeliumGood20:1620:237   

16.2 GB collected

  43   Sat Mar 15 03:29:19 2025 elog-producerenergy scans228TJ-Monopix2175.3 MeVLow Flux Very LowProtonUnknown15.03.2025 03:20:0215.03.2025 03:29:459HVNone 
automatic log for run 228
Comment: