Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 8 of 11  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Typedown Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  146   Sat Dec 14 12:55:41 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon7RaMon63.3 MeV/uLow Flux MediumHeliumGood06:3506:361   Mean rate per spill~ 2-5E5 p/s (online
estimation without proper analysis)
  
  147   Sat Dec 14 12:56:05 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon8RaMon205.2 MeV/uLow Flux HighHeliumGood06:3906:401   Mean rate per spill~ 5e6 p/s (online estimation
without proper analysis)
  
  148   Sat Dec 14 12:56:38 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon9RaMon177.8 MeV/uLow Flux HighHeliumGood06:4006:411   Mean rate per spill~ 4.5e6 p/s (online
estimation without proper analysis)
  
  149   Sat Dec 14 12:57:13 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon10RaMon147.2 MeV/uLow Flux HighHeliumGood06:4206:421   Mean rate per spill~ 3..5e6 p/s (online
estimation without proper analysis)
  
  150   Sat Dec 14 12:58:35 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon11RaMon124.4 MeV/uLow Flux HighHeliumGood06:4306:431   Mean rate per spill~ 4Ee6 p/s (online estimation
without proper analysis)
  
  151   Sat Dec 14 12:59:33 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon12RaMon97.2MeV/uLow Flux HighHeliumGood06:4306:441   Mean rate per spill~ 6Ee6 p/s (online estimation
without proper analysis)
  
  152   Sat Dec 14 13:00:26 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon13RaMon73.2 MeV/uLow Flux HighHeliumGood06:4406:451   Mean rate per spill~ 4Ee6 p/s (online estimation
without proper analysis)
  
  153   Sat Dec 14 13:01:14 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon14RaMon63.3 MeV/uLow Flux HighHeliumGood06:4606:461   Mean rate per spill~ 5Ee6 p/s (online estimation
without proper analysis)
  
  156   Sat Dec 14 13:07:15 2024 Felix Ulrich-PurEnergy vs TOF calibration17TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood08:4609:4256   before run, setups had to be aligned (first
slab in slabholder was put in isocentre.
However, in this run, no slab was used).
  
  157   Sat Dec 14 13:16:33 2024 Felix Ulrich-PurEnergy vs TOF calibration +Alignment of DOGMA setup18TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood09:4209:486   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
  
  158   Sat Dec 14 13:26:29 2024 Felix Ulrich-PurEnergy vs TOF calibration19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon177.8 MeV/uLow Flux MediumHeliumGood10:0810:2517   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

750kHz with Ramon and only 160kHz
  
  159   Sat Dec 14 13:28:57 2024 Felix Ulrich-PurEnergy vs TOF calibration20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux MediumHeliumGood10:3310:385   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

300kHz with Ramon and only 40kHz
  
  160   Sat Dec 14 13:31:49 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood10:4110:5615   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3.5MHz with Ramon and only 600kHz
  
  161   Sat Dec 14 13:34:18 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood10:5811:2325   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3MHz with Ramon and only 300kHz
  
  162   Sat Dec 14 13:35:59 2024 Felix Ulrich-PurEnergy vs TOF calibration23TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood11:2411:3713   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

5MHz with Ramon and only 500kHz
  
  163   Sat Dec 14 13:37:26 2024 Felix Ulrich-PurEnergy vs TOF calibration24TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon73.2 MeV/uLow Flux HighHeliumGood11:4212:0018   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

2MHz with Ramon and only 200kHz
  
  164   Sat Dec 14 13:39:15 2024 Felix Ulrich-PurEnergy vs TOF calibration25TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:0512:2318   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

380 kHz with Ramon and only 180kHz
  
  165   Sat Dec 14 13:40:47 2024 Felix Ulrich-Purthreshold and preamp tests26TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:3512:4914   TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (changed threshold)

Diamond: 500mA, threshold 50
  
  166   Sat Dec 14 13:42:52 2024 Felix Ulrich-Purthreshold and preamp tests 27TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:5213:1624   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000 (changed threshold)

Diamond: 900mA, threshold 50
  
  167   Sat Dec 14 13:45:34 2024 Felix Ulrich-Purthreshold and preamp tests 28TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood13:2013:322   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000 (changed threshold)

Diamond: 900mA, threshold 1000
  
ELOG V3.1.5-fc6679b