96
|
Sun Jun 9 01:27:38 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 25 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:16 | 01:30 | | | | |
3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD
WET measurement |
97
|
Sun Jun 9 01:32:51 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 26 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 01:30 | 01:45 | | | | |
3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230 kHz on LGAD
WET measurement |
98
|
Sun Jun 9 01:48:51 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 27 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:48 | 01:59 | | | | |
4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 470 kHz on LGAD
WET measurement |
100
|
Sun Jun 9 02:02:16 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 28 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 02:00 | 02:14 | | | | |
4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 175 kHz on LGAD
WET measurement |
101
|
Sun Jun 9 02:18:55 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 29 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 02:18 | | | | | |
5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350 kHz on LGAD
WET measurement |
147
|
Sat Dec 14 12:56:05 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 8 | RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 06:39 | 06:40 | 1 | | | |
Mean rate per spill~ 5e6 p/s (online estimation without proper analysis) |
148
|
Sat Dec 14 12:56:38 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 9 | RaMon | 177.8 MeV/u | Low Flux High | Helium | Good | 06:40 | 06:41 | 1 | | | |
Mean rate per spill~ 4.5e6 p/s (online estimation without proper analysis) |
149
|
Sat Dec 14 12:57:13 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 10 | RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 06:42 | 06:42 | 1 | | | |
Mean rate per spill~ 3..5e6 p/s (online estimation without proper analysis) |
150
|
Sat Dec 14 12:58:35 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 11 | RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 06:43 | 06:43 | 1 | | | |
Mean rate per spill~ 4Ee6 p/s (online estimation without proper analysis) |
151
|
Sat Dec 14 12:59:33 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 12 | RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 06:43 | 06:44 | 1 | | | |
Mean rate per spill~ 6Ee6 p/s (online estimation without proper analysis) |
152
|
Sat Dec 14 13:00:26 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 13 | RaMon | 73.2 MeV/u | Low Flux High | Helium | Good | 06:44 | 06:45 | 1 | | | |
Mean rate per spill~ 4Ee6 p/s (online estimation without proper analysis) |
153
|
Sat Dec 14 13:01:14 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 14 | RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 06:46 | 06:46 | 1 | | | |
Mean rate per spill~ 5Ee6 p/s (online estimation without proper analysis) |
154
|
Sat Dec 14 13:02:29 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux Carbon test with RaMon (did not work) | 15 | RaMon | | Low Flux High | Carbon | Crap | 06:55 | 07:01 | 6 | | | |
Low flux carbon did not work
1µs EFE, 30s Extraction, Deg100
we tried different energies (402.MeV/u)-> 120 MeV/u, but unfortunately we did not get any beam |
155
|
Sat Dec 14 13:04:57 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux Carbon test with RaMon (did not work) | 16 | RaMon | | Low Flux High | Carbon | Crap | 07:02 | 07:20 | 18 | | | |
Low flux carbon did not work
5µs EFE, 10s Extraction, Deg100
we tried different energies (402.MeV/u)-> 238 MeV/u, but unfortunately we did not get any beam |
160
|
Sat Dec 14 13:31:49 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 10:41 | 10:56 | 15 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
3.5MHz with Ramon and only 600kHz with TRB-52ps single channel res prae calib |
161
|
Sat Dec 14 13:34:18 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 10:58 | 11:23 | 25 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
3MHz with Ramon and only 300kHz with TRB-44ps single channel res prae calib |
162
|
Sat Dec 14 13:35:59 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 23 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 11:24 | 11:37 | 13 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
5MHz with Ramon and only 500kHz TRB |
163
|
Sat Dec 14 13:37:26 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 24 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 73.2 MeV/u | Low Flux High | Helium | Good | 11:42 | 12:00 | 18 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
2MHz with Ramon and only 200kHz TRB |
164
|
Sat Dec 14 13:39:15 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 25 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:05 | 12:23 | 18 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
380 kHz with Ramon and only 180kHz TRB, 42ps single channel res prae calib |
165
|
Sat Dec 14 13:40:47 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 26 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:35 | 12:49 | 14 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |