Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_mindown Frontend Phantom Phantom thickness Text Attachments
  57   Sat Mar 30 16:15:20 2024 hh, mb, ps1st tests1040TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 16:15:2230.03.2024 16:17:462HV  automatic log for run 1040
Comment:
 tjmonopix2.conf 
  103   Sun Aug 25 06:42:38 2024 tb-crewPiggy test45RD50-MPW4800 MeVLow Flux LowProtonUnknown25.08.2024 06:40:5225.08.2024 06:43:042Normal  automatic log for run 45
Comment:
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  107   Sun Aug 25 06:51:00 2024 tb-crewPiggy test47RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 06:48:2925.08.2024 06:51:272Normal  automatic log for run 47
Comment:
with tracker
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  124   Sun Aug 25 10:06:51 2024 tb-crewonly base59RD50-MPW4800 MeVLow Flux Very LowProtonCrap25.08.2024 10:05:0125.08.2024 10:07:182Normal  automatic log for run 59
Comment:
reducing base threshold
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  129   Sun Aug 25 11:16:09 2024 tb-crewonly base64RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 11:14:1925.08.2024 11:16:362Normal  automatic log for run 64
Comment:
experimental DAC settings
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  130   Sun Aug 25 11:19:53 2024 tb-crewonly base65RD50-MPW4800 MeVLow Flux Very LowProtonUnknown25.08.2024 11:17:2225.08.2024 11:20:202Normal  automatic log for run 65
Comment:
experimental DAC settings
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  140   Fri Dec 13 11:48:21 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon1RaMon205.2 MeV/uLow Flux MediumHeliumGood06:2806:302   Mean rate per spill~ 4-6E5 p/s (online
estimation without proper analysis)
  
  167   Sat Dec 14 13:45:34 2024 Felix Ulrich-Purthreshold and preamp tests 28TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood13:2013:322   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000 (changed threshold)

Diamond: 900mA, threshold 1000
  
  135   Sun Aug 25 12:23:44 2024 tb-crewonly base69RD50-MPW4175.3 MeVLow Flux Very LowProtonUnknown25.08.2024 12:04:3225.08.2024 12:24:1019Normal  automatic log for run 69
Comment:
E-scan
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  155   Sat Dec 14 13:04:57 2024 Felix Ulrich-PurShift 23.11.24 low flux Carbon test with RaMon (did not work)16RaMon Low Flux HighCarbonCrap07:0207:2018   Low flux carbon did not work

5µs EFE, 10s Extraction,
Deg100
  
  163   Sat Dec 14 13:37:26 2024 Felix Ulrich-PurEnergy vs TOF calibration24TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon73.2 MeV/uLow Flux HighHeliumGood11:4212:0018   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

2MHz with Ramon and only 200kHz
  
  164   Sat Dec 14 13:39:15 2024 Felix Ulrich-PurEnergy vs TOF calibration25TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:0512:2318   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

380 kHz with Ramon and only 180kHz
  
  170   Sat Dec 14 13:56:16 2024 Felix Ulrich-PurWET measurement slabs31TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood14:4815:0618 Plastic Water Slabs2cm2cm plastic water

TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000
  
  198   Sat Dec 14 15:39:42 2024 Felix Ulrich-Purplastic mouse radiography60TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood23:5000:0818 plastic mouse pos x=-100, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  207   Sat Dec 14 15:45:05 2024 Felix Ulrich-Purplastic mouse radiography69TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood02:0702:2518 plastic mouse pos x=25, posy=75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HV  automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
 tjmonopix2.conf 
  158   Sat Dec 14 13:26:29 2024 Felix Ulrich-PurEnergy vs TOF calibration19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon177.8 MeV/uLow Flux MediumHeliumGood10:0810:2517   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

750kHz with Ramon and only 160kHz
  
  174   Sat Dec 14 15:12:46 2024 Felix Ulrich-PurWET measurement slabs35TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux HighHeliumGood15:5316:1017 Plastic Water Slabs4cm4cm plastic water

TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000
  
  201   Sat Dec 14 15:41:19 2024 Felix Ulrich-Purplastic mouse radiography63TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:3700:5417 plastic mouse pos x=100, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
  202   Sat Dec 14 15:41:43 2024 Felix Ulrich-Purplastic mouse radiography64TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood00:5401:0817 plastic mouse pos x=175, posy=-75

TRB Setup: 260V bias and 250mA
pre-amps, threshold 5000
  
ELOG V3.1.5-fc6679b