Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 5  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Mar 30 12:28:29 2024, bp, ci, hh, useful datataking, 1024, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:58:45, 30.03.2024 12:30:56, 32, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1024
Comment:
changed thr to 1V (not 100% sure, configure was not executed)
Entry  Sat Mar 30 11:55:55 2024, bp, ci, hh, useful datataking, 1023, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:06:49, 30.03.2024 11:58:22, 51, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1023
Comment:
Entry  Sat Mar 30 11:20:13 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal 
alignment good now
Entry  Sat Mar 30 11:04:10 2024, bp, ci, hh, RD50-MPW4, 1022, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:03:05, 30.03.2024 11:06:37, 3, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1022
Comment:
changed alignment again
Entry  Sat Mar 30 10:39:45 2024, bp, ci, hh, RD50-MPW4, 1021, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 10:37:01, 30.03.2024 10:42:12, 5, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1021
Comment:
no tracker at start of run
Entry  Sat Mar 30 10:34:27 2024, bp, ci, hh, RD50-MPW4, 1020, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 10:33:01, 30.03.2024 10:36:53, 3, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1020
Comment:
Entry  Sat Mar 30 10:28:42 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal 
tracker FADC down, HV not on earlier, restart happening
Entry  Sat Mar 30 10:27:56 2024, bp, ci, hh, RD50-MPW4, 1019, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:28:28, 30.03.2024 10:30:22, 1, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1019
Comment:
Entry  Sat Mar 30 10:25:55 2024, bp, ci, hh, RD50-MPW4, 1018, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:26:17, 30.03.2024 10:28:21, 2, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1018
Comment:
Entry  Sat Mar 30 10:23:06 2024, bp, ci, hh, RD50-MPW4, 1017, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:25:09, 30.03.2024 10:25:33, 0, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1017
Comment:
changed rate to low again, too much "noise"
Entry  Sat Mar 30 10:23:04 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal 
changed rate to low again, too much "noise"
also moved table down and a bit to the left 
Entry  Sat Mar 30 10:10:57 2024, bp, ci, hh, RD50-MPW4, 1016, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:07:51, 30.03.2024 10:13:23, 5, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1016
Comment:
changed rate
Entry  Sat Mar 30 10:05:09 2024, bp, ci, hh, RD50-MPW4, 1015, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:02:17, 30.03.2024 10:07:36, 5, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1015
Comment:
changed rate
Entry  Sat Mar 30 09:59:40 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, , , , Normal 
changed rate
Entry  Sat Mar 30 09:59:25 2024, bp, ci, hh, RD50-MPW4, 1014, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:56:17, 30.03.2024 10:01:51, 5, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1014
Comment:
Entry  Sat Mar 30 09:54:37 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal 
correlations still there after rate change
Entry  Sat Mar 30 09:53:41 2024, bp, ci, hh, RD50-MPW4, 1013, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:46:27, 30.03.2024 09:56:08, 9, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1013
Comment:
Entry  Sat Mar 30 09:43:29 2024, bp, ci, hh, RD50-MPW4, , RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, , , , Normal 
max triggerof tracker set to 100
Entry  Sat Mar 30 09:42:55 2024, bp, ci, hh, RD50-MPW4, 1012, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:39:08, 30.03.2024 09:45:21, 6, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1012
Comment:
changed rate
Entry  Sat Mar 30 09:36:22 2024, bp, ci, hh, RD50-MPW4, 1011, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 09:30:18, 30.03.2024 09:38:48, 8, Normal peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1011
Comment:
testing new tablealignment
ELOG V3.1.5-fc6679b