  Testbeams at MedAustron in 2024, Page 4 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  74   Sat Jun 8 19:57:39 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve3TOF-Cal GSI194.3 MeVLow Flux MediumProtonGood16:5117:28    

600 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 235kHz on LGAD

TOF Calibration Curve

  75   Sat Jun 8 20:05:27 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve4TOF-Cal GSI175.3 MeVLow Flux MediumProtonGood17:3117:54    

500 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 170kHz on LGAD

TOF Calibration Curve

  76   Sat Jun 8 20:07:44 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve5TOF-Cal GSI145.4 MeVLow Flux MediumProtonGood17:5518:24    

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 120kHz on LGAD

TOF Calibration Curve

  77   Sat Jun 8 20:08:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve6TOF-Cal GSI115.7MeVLow Flux MediumProtonGood18:2419:00    

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51    

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD

TOF Calibration Curve

  140   Fri Dec 13 11:48:21 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon1RaMon205.2 MeV/uLow Flux MediumHeliumGood06:2806:302   

Mean rate per spill~ 4-6E5 p/s (online estimation without proper analysis)

  141   Sat Dec 14 12:52:02 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon2RaMon177.8 MeV/uLow Flux MediumHeliumGood06:3106:321   

Mean rate per spill~ 6-8E5 p/s (online estimation without proper analysis)

  142   Sat Dec 14 12:52:57 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon3RaMon147.2 MeV/uLow Flux MediumHeliumGood06:3206:331   

Mean rate per spill~ 2.5-4-5E5 p/s (online estimation without proper analysis)

  143   Sat Dec 14 12:53:28 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon4RaMon124.4 MeV/uLow Flux MediumHeliumGood06:3306:331   

Mean rate per spill~ 2-8E5 p/s (online estimation without proper analysis)

  144   Sat Dec 14 12:54:04 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon5RaMon97.2MeV/uLow Flux MediumHeliumGood06:3306:331   

Mean rate per spill~ 1-5E5 p/s (online estimation without proper analysis)

  145   Sat Dec 14 12:54:55 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon6RaMon73.2 MeV/uLow Flux MediumHeliumGood06:3406:341   

Mean rate per spill~ 4.5-8E5 p/s (online estimation without proper analysis)

  146   Sat Dec 14 12:55:41 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon7RaMon63.3 MeV/uLow Flux MediumHeliumGood06:3506:361   

Mean rate per spill~ 2-5E5 p/s (online estimation without proper analysis)

  156   Sat Dec 14 13:07:15 2024 Felix Ulrich-PurEnergy vs TOF calibration17TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood08:4609:4256   

before run, setups had to be aligned (first slab in slabholder was put in isocentre. However, in this run, no slab was used). Room was closed at 08:10

Beam->Nozzle-> Slabholder->TOF-CAL (TRB)-> DOGMA Setup(Diamond+LGADs)-> RaMon

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

measured 400kHz with Ramon and only 100kHz with LGADs (third LGAD) and 60kHz accepted trrigger rate

beam was shifted vertically by x? cm? (need to lookup again). So TRB setup was shifted with motors such that the He beam was hitting the centre of the LGADs

  157   Sat Dec 14 13:16:33 2024 Felix Ulrich-PurEnergy vs TOF calibration +Alignment of DOGMA setup18TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood09:4209:486   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

DOGMA setup had to be shifted manually to align it with the beam

  158   Sat Dec 14 13:26:29 2024 Felix Ulrich-PurEnergy vs TOF calibration19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon177.8 MeV/uLow Flux MediumHeliumGood10:0810:2517   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

750kHz with Ramon and only 160kHz with TRB, 44ps single channel res preacalib

  159   Sat Dec 14 13:28:57 2024 Felix Ulrich-PurEnergy vs TOF calibration20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux MediumHeliumGood10:3310:385   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

300kHz with Ramon and only 40kHz with TRB--> decision to go to low flux high was made

  22   Sat Mar 30 09:42:55 2024 bp, ci, hhRD50-MPW41012RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:39:0830.03.2024 09:45:216Normal  
automatic log for run 1012
Comment:
changed rate
  23   Sat Mar 30 09:43:29 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal  
max triggerof tracker set to 100
  24   Sat Mar 30 09:53:41 2024 bp, ci, hhRD50-MPW41013RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:46:2730.03.2024 09:56:089Normal  
automatic log for run 1013
Comment: