ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Data t-Start t-Stop Duration_min Frontend
  28   Sat Mar 30 10:05:09 2024 bp, ci, hhRD50-MPW41015RD50-MPW4800 MeVLow Flux MediumProtonGood30.03.2024 10:02:1730.03.2024 10:07:365Normal
automatic log for run 1015
Comment:
changed rate
  29   Sat Mar 30 10:10:57 2024 bp, ci, hhRD50-MPW41016RD50-MPW4800 MeVLow Flux MediumProtonGood30.03.2024 10:07:5130.03.2024 10:13:235Normal
automatic log for run 1016
Comment:
changed rate
  65   Sat Mar 30 19:24:57 2024 hh, mb, psHigh statistics1048TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:02:5230.03.2024 19:27:2424HV
automatic log for run 1048
Comment:
Run with medium settings
  66   Sat Mar 30 19:36:57 2024 hh, mb, psHigh statistics1049TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:28:4430.03.2024 19:39:2410HV
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800)
  67   Sat Mar 30 19:44:43 2024 hh, mb, psHigh statistics1050TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:40:2130.03.2024 19:47:106HV
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
  69   Sat Mar 30 20:27:35 2024 hh, mb, psHigh statistics1052TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 20:17:1130.03.2024 20:30:0212HV
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
  73   Sat Jun 8 19:56:37 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve2TOF-Cal GSI252.7 MeVLow Flux MediumProtonGood16:2916:47  

1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD

TOF Calibration Curve

  74   Sat Jun 8 19:57:39 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve3TOF-Cal GSI194.3 MeVLow Flux MediumProtonGood16:5117:28  

600 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 235kHz on LGAD

TOF Calibration Curve

  75   Sat Jun 8 20:05:27 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve4TOF-Cal GSI175.3 MeVLow Flux MediumProtonGood17:3117:54  

500 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 170kHz on LGAD

TOF Calibration Curve

  76   Sat Jun 8 20:07:44 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve5TOF-Cal GSI145.4 MeVLow Flux MediumProtonGood17:5518:24  

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 120kHz on LGAD

TOF Calibration Curve

  77   Sat Jun 8 20:08:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve6TOF-Cal GSI115.7MeVLow Flux MediumProtonGood18:2419:00  

400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42  

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 65kHz on LGAD

TOF Calibration Curve

  79   Sat Jun 8 20:11:00 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve8TOF-Cal GSI83 MeVLow Flux MediumProtonGood19:4220:51  

300 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 35kHz on LGAD

TOF Calibration Curve

  22   Sat Mar 30 09:42:55 2024 bp, ci, hhRD50-MPW41012RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:39:0830.03.2024 09:45:216Normal
automatic log for run 1012
Comment:
changed rate
  23   Sat Mar 30 09:43:29 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
max triggerof tracker set to 100
  24   Sat Mar 30 09:53:41 2024 bp, ci, hhRD50-MPW41013RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:46:2730.03.2024 09:56:089Normal
automatic log for run 1013
Comment:
  25   Sat Mar 30 09:54:37 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
correlations still there after rate change
  26   Sat Mar 30 09:59:25 2024 bp, ci, hhRD50-MPW41014RD50-MPW4800 MeVLow Flux LowProtonGood30.03.2024 09:56:1730.03.2024 10:01:515Normal
automatic log for run 1014
Comment:
  30   Sat Mar 30 10:23:04 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux LowProtonGood   Normal
changed rate to low again, too much "noise"
also moved table down and a bit to the left