Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 4 of 4  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Text Attachments
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999         Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4
shift: mpw4-tj-monopix2_TLU_00-000999.xml 
  
  10   Sat Mar 30 07:59:55 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonCrap   Normalcurrently no beam   
  9   Sat Mar 30 07:59:41 2024 bp, ci, hhRD50-MPW41006RD50-MPW4800 MeVLow Flux Very LowProtonGood30.03.2024 07:46:5030.03.2024 08:02:0815Normalautomatic log for run 1006
Comment:
beautifully correlated :D
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  8   Sat Mar 30 07:44:15 2024 bp, ci, hhRD50-MPW41005RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 07:25:5130.03.2024 07:46:4120Normalautomatic log for run 1005
Comment:
beautifully correlated :D
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  7   Sat Mar 30 07:22:49 2024 bp, ci, hhRD50-MPW41004RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 07:14:5130.03.2024 07:25:1610Normalautomatic log for run 1004
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  6   Sat Mar 30 07:11:30 2024 bp, ci, hhRD50-MPW41003RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 07:12:1930.03.2024 07:13:571Normalautomatic log for run 1003
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  5   Sat Mar 30 07:09:36 2024 bp, ci, hhRD50-MPW41002RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 07:11:1530.03.2024 07:12:030Normalautomatic log for run 1002
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  4   Sat Mar 30 07:00:10 2024 bp, ci, hhRD50-MPW41001RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 06:58:0330.03.2024 07:02:364Normalautomatic log for run 1001
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  3   Sat Mar 30 06:54:51 2024 bp, ci, hhRD50-MPW41000RD50-MPW4800 MeVLow Flux Very LowProtonUnknown30.03.2024 06:56:2330.03.2024 06:57:180Normalautomatic log for run 1000
Comment:
1st test runs
 peary_config.cfgmatrix_mpw4.txtmpw4.conf 
  2   Sat Mar 30 06:53:31 2024 bp, ci, hhRD50-MPW4 RD50-MPW4800 MeVLow Flux Very LowProtonUnknown   Normalabout to start

geo and eudaq ini attached
 mpw4.inidetectors.geo 
  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D              
ELOG V3.1.5-fc6679b