| ID | Date | Author | Subject | Run Number | DUT | Beam Energy | Rate Setting | Particle Type | Data | t-Start | t-Stop | Duration_min | Frontend | Phantom | Phantom thickness | Text |  | 
| 218 | Sat Dec 14 15:50:19 2024 | Felix Ulrich-Pur | LGAD+Diamond test with clinical carbon beam | 80 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 402MeV/u |  | Carbon | Good | 05:15 | 05:50 | 35 |  |  |  | Carbon Deg10 (clinical rate) 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 217 | Sat Dec 14 15:49:58 2024 | Felix Ulrich-Pur | plastic mouse radiography | 79 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:51 | 05:05 | 14 |  | plastic mouse |  | pos x=250, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 216 | Sat Dec 14 15:49:32 2024 | Felix Ulrich-Pur | plastic mouse radiography | 78 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:36 | 04:50 | 14 |  | plastic mouse |  | pos x=175, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 215 | Sat Dec 14 15:49:12 2024 | Felix Ulrich-Pur | plastic mouse radiography | 77 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:22 | 04:36 | 14 |  | plastic mouse |  | pos x=100, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 214 | Sat Dec 14 15:48:49 2024 | Felix Ulrich-Pur | plastic mouse radiography | 76 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 04:06 | 04:21 | 15 |  | plastic mouse |  | pos x=25, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 213 | Sat Dec 14 15:48:26 2024 | Felix Ulrich-Pur | plastic mouse radiography | 75 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:52 | 04:05 | 13 |  | plastic mouse |  | pos x=-25, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 212 | Sat Dec 14 15:47:59 2024 | Felix Ulrich-Pur | plastic mouse radiography | 74 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:35 | 03:51 | 16 |  | plastic mouse |  | pos x=-100, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 211 | Sat Dec 14 15:47:29 2024 | Felix Ulrich-Pur | plastic mouse radiography | 73 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:20 | 03:55 | 25 |  | plastic mouse |  | pos x=-175, posy=-175 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 210 | Sat Dec 14 15:46:54 2024 | Felix Ulrich-Pur | plastic mouse radiography | 72 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 03:03 | 03:19 | 16 |  | plastic mouse |  | pos x=-175, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 209 | Sat Dec 14 15:46:16 2024 | Felix Ulrich-Pur | plastic mouse radiography | 71 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:46 | 03:03 | 17 |  | plastic mouse |  | pos x=-100, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 208 | Sat Dec 14 15:45:36 2024 | Felix Ulrich-Pur | plastic mouse radiography | 70 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:25 | 02:45 | 20 |  | plastic mouse |  | pos x=-25, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 207 | Sat Dec 14 15:45:05 2024 | Felix Ulrich-Pur | plastic mouse radiography | 69 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 02:07 | 02:25 | 18 |  | plastic mouse |  | pos x=25, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 206 | Sat Dec 14 15:43:45 2024 | Felix Ulrich-Pur | plastic mouse radiography | 68 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:51 | 02:07 | 16 |  | plastic mouse |  | pos x=100, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 205 | Sat Dec 14 15:43:01 2024 | Felix Ulrich-Pur | plastic mouse radiography | 67 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:35 | 01:51 | 16 |  | plastic mouse |  | pos x=175, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 204 | Sat Dec 14 15:42:32 2024 | Felix Ulrich-Pur | plastic mouse radiography | 66 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:21 | 01:34 | 13 |  | plastic mouse |  | pos x=250, posy=75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 203 | Sat Dec 14 15:42:01 2024 | Felix Ulrich-Pur | plastic mouse radiography | 65 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 01:08 | 01:20 | 12 |  | plastic mouse |  | pos x=250, posy=-75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 202 | Sat Dec 14 15:41:43 2024 | Felix Ulrich-Pur | plastic mouse radiography | 64 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:54 | 01:08 | 17 |  | plastic mouse |  | pos x=175, posy=-75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 201 | Sat Dec 14 15:41:19 2024 | Felix Ulrich-Pur | plastic mouse radiography | 63 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:37 | 00:54 | 17 |  | plastic mouse |  | pos x=100, posy=-75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 200 | Sat Dec 14 15:40:45 2024 | Felix Ulrich-Pur | plastic mouse radiography | 62 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:22 | 00:37 | 15 |  | plastic mouse |  | pos x=25, posy=-75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  | 
| 199 | Sat Dec 14 15:40:09 2024 | Felix Ulrich-Pur | plastic mouse radiography | 61 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 00:09 | 00:22 | 13 |  | plastic mouse |  | pos x=-25, posy=-75 
 TRB Setup: 260V bias and 250mA
 pre-amps, threshold 5000
 |  |