Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 11 of 11  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  91   Sun Jun 9 00:10:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser20TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:3100:00    5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  97   Sun Jun 9 01:32:51 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen26TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:3001:45    3 cm dense bone (in isocentre)
1.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  100   Sun Jun 9 02:02:16 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen28TOF-Cal GSI145.4 MeVLow Flux HighProtonGood02:0002:14    4 cm dense bone (in isocentre)
1.4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  143   Sat Dec 14 12:53:28 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon4RaMon124.4 MeV/uLow Flux MediumHeliumGood06:3306:331   Mean rate per spill~ 2-8E5 p/s (online
estimation without proper analysis)
  
  150   Sat Dec 14 12:58:35 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon11RaMon124.4 MeV/uLow Flux HighHeliumGood06:4306:431   Mean rate per spill~ 4Ee6 p/s (online estimation
without proper analysis)
  
  162   Sat Dec 14 13:35:59 2024 Felix Ulrich-PurEnergy vs TOF calibration23TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood11:2411:3713   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

5MHz with Ramon and only 500kHz
  
  77   Sat Jun 8 20:08:55 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve6TOF-Cal GSI115.7MeVLow Flux MediumProtonGood18:2419:00    400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
  
  78   Sat Jun 8 20:09:25 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve7TOF-Cal GSI100.4 MeVLow Flux MediumProtonGood19:0019:42    300 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 65kHz
on LGAD
  
  136   Sun Aug 25 12:39:45 2024 tb-crewonly base70RD50-MPW4100.4 MeVLow Flux Very LowProtonUnknown25.08.2024 12:24:3625.08.2024 12:40:1215Normal  automatic log for run 70
Comment:
E-scan
 peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf 
  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D                
  11   Sat Mar 30 08:05:59 2024 Christian IrmlerRD50-MPW4999           Tracker calibration run: mpw4-tj-monopix2_00-000999.xml
Generated global xml file for MPW4
shift: mpw4-tj-monopix2_TLU_00-000999.xml 
  
Entry is currently edited by RD50 Generic User on 193.170.243.131    123   Sun Aug 25 10:02:35 2024 RD50 Generic Userinit_geo_file            position of duts needs to be switched  detectors.geo 
  139   Mon Aug 26 09:18:25 2024 RD50 Generic Usergeo            new geo file with adjusted dut position  detectors_new.geo 
  154   Sat Dec 14 13:02:29 2024 Felix Ulrich-PurShift 23.11.24 low flux Carbon test with RaMon (did not work)15RaMon Low Flux HighCarbonCrap06:5507:016   Low flux carbon did not work

1µs EFE, 30s Extraction,
Deg100
  
  155   Sat Dec 14 13:04:57 2024 Felix Ulrich-PurShift 23.11.24 low flux Carbon test with RaMon (did not work)16RaMon Low Flux HighCarbonCrap07:0207:2018   Low flux carbon did not work

5µs EFE, 10s Extraction,
Deg100
  
ELOG V3.1.5-fc6679b