ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
|
75
|
Sat Jun 8 20:05:27 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 4 | TOF-Cal GSI | 175.3 MeV | Low Flux Medium | Proton | Good | 17:31 | 17:54 | | | | | 500 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 170kHz
on LGAD |
|
135
|
Sun Aug 25 12:23:44 2024 |
tb-crew | only base | 69 | RD50-MPW4 | 175.3 MeV | Low Flux Very Low | Proton | Unknown | 25.08.2024 12:04:32 | 25.08.2024 12:24:10 | 19 | Normal | | | automatic log for run 69
Comment:
E-scan |
|
142
|
Sat Dec 14 12:52:57 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 3 | RaMon | 147.2 MeV/u | Low Flux Medium | Helium | Good | 06:32 | 06:33 | 1 | | | | Mean rate per spill~ 2.5-4-5E5 p/s (online
estimation without proper analysis) |
|
149
|
Sat Dec 14 12:57:13 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 10 | RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 06:42 | 06:42 | 1 | | | | Mean rate per spill~ 3..5e6 p/s (online
estimation without proper analysis) |
|
159
|
Sat Dec 14 13:28:57 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 20 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux Medium | Helium | Good | 10:33 | 10:38 | 5 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
300kHz with Ramon and only 40kHz |
|
160
|
Sat Dec 14 13:31:49 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 10:41 | 10:56 | 15 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
3.5MHz with Ramon and only 600kHz |
|
169
|
Sat Dec 14 13:49:20 2024 |
Felix Ulrich-Pur | WET measurement slabs | 30 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 14:02 | 14:45 | 43 | | Plastic Water Slabs | 1cm | 1cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
171
|
Sat Dec 14 15:09:34 2024 |
Felix Ulrich-Pur | WET measurement slabs | 32 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:06 | 15:19 | 13 | | Plastic Water Slabs | 2cm | 2cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
173
|
Sat Dec 14 15:12:01 2024 |
Felix Ulrich-Pur | WET measurement slabs | 34 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 15:37 | 15:48 | 11 | | Plastic Water Slabs | 3cm | 3cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
175
|
Sat Dec 14 15:15:04 2024 |
Felix Ulrich-Pur | WET measurement slabs | 36 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:11 | 16:23 | 12 | | Plastic Water Slabs | 4cm | 4cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
177
|
Sat Dec 14 15:17:10 2024 |
Felix Ulrich-Pur | WET measurement slabs | 38 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 16:42 | 16:55 | 13 | | Plastic Water Slabs | 5cm | 5cm plastic water
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
179
|
Sat Dec 14 15:18:48 2024 |
Felix Ulrich-Pur | WET measurement slabs | 40 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 17:14 | 17:28 | 14 | | Dense Bone Slabs | 1cm | 1cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
181
|
Sat Dec 14 15:20:52 2024 |
Felix Ulrich-Pur | WET measurement slabs | 42 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 17:48 | 18:00 | 12 | | Dense Bone Slabs | 2cm | 2cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
183
|
Sat Dec 14 15:23:21 2024 |
Felix Ulrich-Pur | WET measurement slabs | 44 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 18:19 | 18:33 | 14 | | Dense Bone Slabs | 2cm | 3cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
185
|
Sat Dec 14 15:25:12 2024 |
Felix Ulrich-Pur | WET measurement slabs | 46 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 18:55 | 19:11 | 16 | | Dense Bone Slabs | 4cm | 4cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
187
|
Sat Dec 14 15:27:08 2024 |
Felix Ulrich-Pur | WET measurement slabs | 48 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 19:30 | 19:50 | 20 | | Dense Bone Slabs | 5cm | 5cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
76
|
Sat Jun 8 20:07:44 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 5 | TOF-Cal GSI | 145.4 MeV | Low Flux Medium | Proton | Good | 17:55 | 18:24 | | | | | 400 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 120kHz
on LGAD |
|
82
|
Sat Jun 8 21:43:26 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 11 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 21:39 | 21:48 | | | | | 1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
84
|
Sat Jun 8 22:12:06 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 13 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 22:05 | 22:34 | | | | | 2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
89
|
Sun Jun 9 00:07:17 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 18 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 23:04 | 23:20 | | | | | 4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|