ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
Text |
 |
180
|
Sat Dec 14 15:19:57 2024 |
Felix Ulrich-Pur | WET measurement slabs | 41 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 17:32 | 17:44 | 12 | | Dense Bone Slabs | 2cm | 2cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
182
|
Sat Dec 14 15:21:44 2024 |
Felix Ulrich-Pur | WET measurement slabs | 43 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 18:04 | 18:18 | 14 | | Dense Bone Slabs | 3cm | 3cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
184
|
Sat Dec 14 15:24:22 2024 |
Felix Ulrich-Pur | WET measurement slabs | 45 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 18:37 | 18:51 | 14 | | Dense Bone Slabs | 4cm | 4cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
186
|
Sat Dec 14 15:26:18 2024 |
Felix Ulrich-Pur | WET measurement slabs | 47 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux High | Helium | Good | 19:16 | 19:29 | 13 | | Dense Bone Slabs | 5cm | 5cm dense bone
TRB Setup: 260V bias and 250mA
pre-amps, threshold 1000 |
|
74
|
Sat Jun 8 19:57:39 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 3 | TOF-Cal GSI | 194.3 MeV | Low Flux Medium | Proton | Good | 16:51 | 17:28 | | | | | 600 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 235kHz
on LGAD |
|
81
|
Sat Jun 8 21:42:13 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 10 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 21:27 | 21:39 | | | | | 1cm plastic water (in isocentre)
6 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
83
|
Sat Jun 8 21:54:59 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 12 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 21:53 | 22:05 | | | | | 2cm plastic water (in isocentre)
5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
85
|
Sat Jun 8 22:38:41 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 14 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:19 | 22.34 | | | | | 3 cm plastic water (in isocentre)
4.3 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
87
|
Sun Jun 9 00:05:11 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser (wrong energy) | 16 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Crap | 22:50 | 22:52 | | | | | wrong energy don't use |
|
88
|
Sun Jun 9 00:06:01 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 17 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:53 | 23:04 | | | | | 4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
90
|
Sun Jun 9 00:08:07 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 19 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 23:20 | 23:30 | | | | | 5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
92
|
Sun Jun 9 00:12:41 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 21 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 00:00 | 00:14 | | | | | 1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
94
|
Sun Jun 9 01:25:26 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 23 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 00:30 | 01:02 | | | | | 2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
96
|
Sun Jun 9 01:27:38 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 25 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:16 | 01:30 | | | | | 3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
98
|
Sun Jun 9 01:48:51 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 27 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:48 | 01:59 | | | | | 4 cm dense bone (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
101
|
Sun Jun 9 02:18:55 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 29 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 02:18 | | | | | | 5 cm dense bone (in isocentre)
1.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and |
|
141
|
Sat Dec 14 12:52:02 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 2 | RaMon | 177.8 MeV/u | Low Flux Medium | Helium | Good | 06:31 | 06:32 | 1 | | | | Mean rate per spill~ 6-8E5 p/s (online
estimation without proper analysis) |
|
148
|
Sat Dec 14 12:56:38 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 9 | RaMon | 177.8 MeV/u | Low Flux High | Helium | Good | 06:40 | 06:41 | 1 | | | | Mean rate per spill~ 4.5e6 p/s (online
estimation without proper analysis) |
|
158
|
Sat Dec 14 13:26:29 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 19 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 177.8 MeV/u | Low Flux Medium | Helium | Good | 10:08 | 10:25 | 17 | | | | TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
750kHz with Ramon and only 160kHz |
|
75
|
Sat Jun 8 20:05:27 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 4 | TOF-Cal GSI | 175.3 MeV | Low Flux Medium | Proton | Good | 17:31 | 17:54 | | | | | 500 khz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 170kHz
on LGAD |
|