ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness
  65   Sat Mar 30 19:24:57 2024 hh, mb, psHigh statistics1048TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:02:5230.03.2024 19:27:2424HV  
automatic log for run 1048
Comment:
Run with medium settings
  66   Sat Mar 30 19:36:57 2024 hh, mb, psHigh statistics1049TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:28:4430.03.2024 19:39:2410HV  
automatic log for run 1049
Comment:
Try with increased veto period of 20us (800)
  67   Sat Mar 30 19:44:43 2024 hh, mb, psHigh statistics1050TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:40:2130.03.2024 19:47:106HV  
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
  68   Sat Mar 30 20:13:29 2024 hh, mb, psHigh statistics1051TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 19:48:3630.03.2024 20:15:5527HV  
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
  69   Sat Mar 30 20:27:35 2024 hh, mb, psHigh statistics1052TJ-Monopix2800 MeVLow Flux MediumProtonUnknown30.03.2024 20:17:1130.03.2024 20:30:0212HV  
automatic log for run 1052
Comment:
Back to stock veto period of 7us (100)
  70   Sat Mar 30 20:46:41 2024 hh, mb, psHigh statistics1053TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:31:1430.03.2024 20:49:0817HV  
automatic log for run 1053
Comment:
Back to stock veto period of 7us (100)
Lets try with high
  71   Sat Mar 30 20:51:31 2024 hh, mb, psHigh statistics1054TJ-Monopix2800 MeVLow Flux HighProtonUnknown30.03.2024 20:50:5330.03.2024 20:53:583HV  
automatic log for run 1054
Comment:
Litle high settings run
  157   Sat Dec 14 13:16:33 2024 Felix Ulrich-PurEnergy vs TOF calibration +Alignment of DOGMA setup18TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood09:4209:486   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

DOGMA setup had to be shifted manually to align it with the beam

  156   Sat Dec 14 13:07:15 2024 Felix Ulrich-PurEnergy vs TOF calibration17TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood08:4609:4256   

before run, setups had to be aligned (first slab in slabholder was put in isocentre. However, in this run, no slab was used). Room was closed at 08:10

Beam->Nozzle-> Slabholder->TOF-CAL (TRB)-> DOGMA Setup(Diamond+LGADs)-> RaMon

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

measured 400kHz with Ramon and only 100kHz with LGADs (third LGAD) and 60kHz accepted trrigger rate

beam was shifted vertically by x? cm? (need to lookup again). So TRB setup was shifted with motors such that the He beam was hitting the centre of the LGADs

  158   Sat Dec 14 13:26:29 2024 Felix Ulrich-PurEnergy vs TOF calibration19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon177.8 MeV/uLow Flux MediumHeliumGood10:0810:2517   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

750kHz with Ramon and only 160kHz with TRB, 44ps single channel res preacalib

  159   Sat Dec 14 13:28:57 2024 Felix Ulrich-PurEnergy vs TOF calibration20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux MediumHeliumGood10:3310:385   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

300kHz with Ramon and only 40kHz with TRB--> decision to go to low flux high was made

  160   Sat Dec 14 13:31:49 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood10:4110:5615   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

3.5MHz with Ramon and only 600kHz with TRB-52ps single channel res prae calib

  161   Sat Dec 14 13:34:18 2024 Felix Ulrich-PurEnergy vs TOF calibration22TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood10:5811:2325   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

3MHz with Ramon and only 300kHz with TRB-44ps single channel res prae calib

  162   Sat Dec 14 13:35:59 2024 Felix Ulrich-PurEnergy vs TOF calibration23TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood11:2411:3713   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

5MHz with Ramon and only 500kHz TRB

  163   Sat Dec 14 13:37:26 2024 Felix Ulrich-PurEnergy vs TOF calibration24TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon73.2 MeV/uLow Flux HighHeliumGood11:4212:0018   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

2MHz with Ramon and only 200kHz TRB

  164   Sat Dec 14 13:39:15 2024 Felix Ulrich-PurEnergy vs TOF calibration25TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:0512:2318   

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

380 kHz with Ramon and only 180kHz TRB, 42ps single channel res prae calib

  1   Sat Mar 30 06:34:39 2024 Bernhard PilslAnd a new testbeam starts :D            
  44   Sat Mar 30 15:02:07 2024 hh, mb, ps1st tests1027TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 14:52:5430.03.2024 15:04:3211HV  
automatic log for run 1027
Comment:
  45   Sat Mar 30 15:05:28 2024 hh, mb, ps1st tests1028TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:04:4730.03.2024 15:07:553HV  
automatic log for run 1028
Comment:
  46   Sat Mar 30 15:08:33 2024 hh, mb, ps1st tests1029TJ-Monopix2800 MeVLow Flux LowProtonUnknown30.03.2024 15:08:2630.03.2024 15:11:002HV  
automatic log for run 1029
Comment:
ELOG V3.1.5-fc6679b