ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Events Data t-Start t-Stop Duration_min Frontend
  34   Sun Feb 19 02:05:04 2023 BP_PSINFO common8005kHzProton Unknown    
change TH before run 26, chip was getting noisy to 1,15V
Before it was at 1,08
  35   Sun Feb 19 02:05:35 2023 BP_PSbeam27common8005kHzProton693679Unknown19.02.2023 02:03:5819.02.2023 02:05:34  
automatic log for run 27
  36   Sun Feb 19 02:08:06 2023 BP_PSbeam28common8005kHzProton752984Unknown19.02.2023 02:06:3019.02.2023 02:08:06  
automatic log for run 28
  37   Sun Feb 19 02:08:34 2023 BP_PSINFO common8005kHzProton Unknown    
TH change again before run 27, new TH= 1.1
  38   Sun Feb 19 02:16:56 2023 BP_PSbeam29common8005kHzProton232363Unknown19.02.2023 02:15:1519.02.2023 02:16:56  
automatic log for run 29
  39   Sun Feb 19 02:47:40 2023 BP_PSbeam30common8005kHzProton10864033Unknown19.02.2023 02:22:4719.02.2023 02:47:40  
automatic log for run 30
  40   Sun Feb 19 03:03:38 2023 BP_PSbeam31common8005kHzProton75989Unknown19.02.2023 03:03:2519.02.2023 03:03:38  
automatic log for run 31
  56   Thu Apr 27 15:42:25 2023 Felix Ulrich-Purlow flux p800 recommissioning002 8005kHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
rate slightly lower due to additional material in front
 

  104   Sat May 6 09:31:55 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
alignment of MPW3 seems better
  105   Sat May 6 09:41:50 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed rate to 5kHz
  107   Sat May 6 09:50:52 2023 cibpdata-taking57RD50-MPW38005kHzProton2315658Unknown06.05.2023 09:24:5806.05.2023 09:50:02 Normal
automatic log for run 57
Comment:
  108   Sat May 6 09:51:57 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed mpx2 settings by max
  109   Sat May 6 10:01:28 2023 cibpdata-taking58RD50-MPW38005kHzProton931155Unknown06.05.2023 09:51:3206.05.2023 10:00:38 Normal
automatic log for run 58
Comment:
  110   Sat May 6 10:08:09 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
no MPX2 data atm, problem with datacollector
  111   Sat May 6 10:12:23 2023 cibpdata-taking59RD50-MPW38005kHzProton1039920Unknown06.05.2023 10:01:2406.05.2023 10:11:32 Normal
automatic log for run 59
Comment:
  177   Sat May 6 21:46:56 2023   123common8005kHzProton2987729Unknown06.05.2023 21:41:3706.05.2023 21:46:04 Normal
automatic log for run 123
Comment:
  178   Sat May 6 21:58:14 2023   124common8005kHzProton306082Good06.05.2023 21:50:0406.05.2023 21:57:21 Normal
automatic log for run 124
Comment:
Alignment run low flux
  55   Thu Apr 27 15:40:07 2023 Felix Ulrich-Purlow flux p800 recommissioning001 8002kHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
Rates slightly lower due to additional material in front of RaMon.

  41   Sun Feb 19 03:09:26 2023 BP_PSbeam32RD50-MPW3800200kHzProton2391117Unknown19.02.2023 03:03:4719.02.2023 03:09:26  
automatic log for run 32
sieht gut aus, hinten ist sensor noisy!
  42   Sun Feb 19 03:28:55 2023  beam33RD50-MPW3800200kHzProton7084523Unknown19.02.2023 03:13:0919.02.2023 03:28:55  
automatic log for run 33