63
|
Thu Apr 27 15:49:27 2023 |
Felix Ulrich-Pur | LGAD beam telescope calibration | 010 | | 252.7 | Low Flux Medium | Proton | | Good | | | | | 22.04.23 23:58 trigger on third LGAD
no DUT
beam was down between 00:05 and |
|
62
|
Thu Apr 27 15:48:29 2023 |
Felix Ulrich-Pur | LGAD beam telescope calibration | 009 | | 83 | Low Flux Medium | Proton | | Good | | | | | 22.04.23 23:35 trigger on third LGAD
no DUT |
|
61
|
Thu Apr 27 15:47:05 2023 |
Felix Ulrich-Pur | LGAD beam telescope calibration | 008 | | 800 | 200kHz | Proton | | Good | | | | | 22.04.23 23:20 trigger on third LGAD
beam spot was off. telescope was
shifted |
|
60
|
Thu Apr 27 15:45:23 2023 |
Felix Ulrich-Pur | LGAD beam telescope calibration | 007 | | 800 | 200kHz | Proton | | Good | | | | | 22.04.23 trigger on second LGAD (run 006
is missing since cable of pre-amps was loose
and 3rd sensor signal was lost) |
|
59
|
Thu Apr 27 15:44:37 2023 |
Felix Ulrich-Pur | low flux p800 recommissioning | 005 | | 800 | 1.2MHz | Proton | | Good | | | | | Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam. |
|
58
|
Thu Apr 27 15:43:48 2023 |
Felix Ulrich-Pur | low flux p800 recommissioning | 004 | | 800 | 1.2MHz | Proton | | Good | | | | | Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam. |
|
57
|
Thu Apr 27 15:43:21 2023 |
Felix Ulrich-Pur | low flux p800 recommissioning | 003 | | 800 | 200kHz | Proton | | Good | | | | | Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam. |
|
56
|
Thu Apr 27 15:42:25 2023 |
Felix Ulrich-Pur | low flux p800 recommissioning | 002 | | 800 | 5kHz | Proton | | Good | | | | | Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam. |
|
55
|
Thu Apr 27 15:40:07 2023 |
Felix Ulrich-Pur | low flux p800 recommissioning | 001 | | 800 | 2kHz | Proton | | Good | | | | | Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam. |
|
1
|
Sat Feb 18 14:48:36 2023 |
Bernhard Pilsl | MPW3 Kalibration / Config Files | | | | | | | | | | | | Initial config files for the RD50_MPW3
Peary device |
  |
4
|
Sat Feb 18 22:17:31 2023 |
Bernhard Pilsl | Attention RUN NUMBER | | | | | | | | | | | | Due to bug in Elog-RC entries here for
the shift on 18.02.2023 are bigger (+1) than
the one stored in the data file names |
|
5
|
Sat Feb 18 22:18:39 2023 |
BP_PS | Beam | | common | 800 | 5kHz | Proton | | Unknown | | | | | Status 22:19, waiting for beam, vakuum Problem
in der Quelle |
|
6
|
Sat Feb 18 22:26:47 2023 |
BP_PS | Beam | | common | 800 | 5kHz | Proton | | Unknown | | | | | Status: Beam bekommen um 22:23 |
|
9
|
Sat Feb 18 22:37:45 2023 |
BP_PS | INFO | | common | 800 | 5kHz | Proton | | Unknown | | | | | z positions:
DSSD1: 0mm
DSSD2: 48mm
|
|
16
|
Sat Feb 18 23:58:44 2023 |
BP_PS | INFO | | common | 800 | 5kHz | Proton | | Unknown | | | | | Moved DUT 4mm before run 9 |
|
34
|
Sun Feb 19 02:05:04 2023 |
BP_PS | INFO | | common | 800 | 5kHz | Proton | | Unknown | | | | | change TH before run 26, chip was getting
noisy to 1,15V
Before it was at 1,08 |
|
37
|
Sun Feb 19 02:08:34 2023 |
BP_PS | INFO | | common | 800 | 5kHz | Proton | | Unknown | | | | | TH change again before run 27, new TH= 1.1 |
|
95
|
Sat May 6 08:09:15 2023 |
cibp | 1st tests | | RD50-MPW3 | 800 | 200kHz | Proton | | Unknown | | | | Normal | changed MPX2 trigger veto from 625us -> 100us
veto length |
|
99
|
Sat May 6 09:02:17 2023 |
cibp | 1st tests | | RD50-MPW3 | 800 | 200kHz | Proton | | Unknown | | | | Normal | moved whole setup by ~2mm in x |
|
100
|
Sat May 6 09:04:46 2023 |
cibp | 1st tests | | RD50-MPW3 | 800 | 200kHz | Proton | | Unknown | | | | Normal | apperently wrong direction, adjusting again
moved 2mm (from origin) in other direction |
|