ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Events Data t-Start t-Stop Duration_min Frontend Text Attachments
  63   Thu Apr 27 15:49:27 2023 Felix Ulrich-PurLGAD beam telescope calibration010 252.7Low Flux MediumProton Good    22.04.23 23:58 trigger on third LGAD

no DUT

beam was down between 00:05 and
  
  62   Thu Apr 27 15:48:29 2023 Felix Ulrich-PurLGAD beam telescope calibration009 83Low Flux MediumProton Good    22.04.23 23:35 trigger on third LGAD

no DUT
  
  61   Thu Apr 27 15:47:05 2023 Felix Ulrich-PurLGAD beam telescope calibration008 800200kHzProton Good    22.04.23 23:20 trigger on third LGAD

beam spot was off. telescope was
shifted
  
  60   Thu Apr 27 15:45:23 2023 Felix Ulrich-PurLGAD beam telescope calibration007 800200kHzProton Good    22.04.23 trigger on second LGAD (run 006
is missing since cable of pre-amps was loose
and 3rd sensor signal was lost)
  
  59   Thu Apr 27 15:44:37 2023 Felix Ulrich-Purlow flux p800 recommissioning005 8001.2MHzProton Good    Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam.
  
  58   Thu Apr 27 15:43:48 2023 Felix Ulrich-Purlow flux p800 recommissioning004 8001.2MHzProton Good    Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam.
  
  57   Thu Apr 27 15:43:21 2023 Felix Ulrich-Purlow flux p800 recommissioning003 800200kHzProton Good    Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam.
  
  56   Thu Apr 27 15:42:25 2023 Felix Ulrich-Purlow flux p800 recommissioning002 8005kHzProton Good    Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam.
  
  55   Thu Apr 27 15:40:07 2023 Felix Ulrich-Purlow flux p800 recommissioning001 8002kHzProton Good    Measurement with RaMon 22.04.23 (not placed
in isocentre) LGAD beam telescope was placed
in front. LGADs were moved out of the beam.
  
  1   Sat Feb 18 14:48:36 2023 Bernhard PilslMPW3 Kalibration / Config Files           Initial config files for the RD50_MPW3
Peary device
 trimdacs_maus_230218config.cfgmatrix_maus_230218 
  4   Sat Feb 18 22:17:31 2023 Bernhard PilslAttention RUN NUMBER           Due to bug in Elog-RC entries here for
the shift on 18.02.2023 are bigger (+1) than
the one stored in the data file names
  
  5   Sat Feb 18 22:18:39 2023 BP_PSBeam common8005kHzProton Unknown    Status 22:19, waiting for beam, vakuum Problem
in der Quelle
  
  6   Sat Feb 18 22:26:47 2023 BP_PSBeam common8005kHzProton Unknown    Status: Beam bekommen um 22:23   
  9   Sat Feb 18 22:37:45 2023 BP_PSINFO common8005kHzProton Unknown    z positions: 
DSSD1: 0mm
DSSD2: 48mm
  
  16   Sat Feb 18 23:58:44 2023 BP_PSINFO common8005kHzProton Unknown    Moved DUT 4mm before run 9   
  34   Sun Feb 19 02:05:04 2023 BP_PSINFO common8005kHzProton Unknown    change TH before run 26, chip was getting
noisy to 1,15V
Before it was at 1,08
  
  37   Sun Feb 19 02:08:34 2023 BP_PSINFO common8005kHzProton Unknown    TH change again before run 27, new TH= 1.1   
  95   Sat May 6 08:09:15 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normalchanged MPX2 trigger veto from 625us -> 100us
veto length
  
  99   Sat May 6 09:02:17 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normalmoved whole setup by ~2mm in x   
  100   Sat May 6 09:04:46 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normalapperently wrong direction, adjusting again
moved 2mm (from origin) in other direction
  
ELOG V3.1.5-fc6679b