ID Date Author Subject Run Number DUT Beam Energy Rate Settingdown Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  280   Sun Nov 7 18:59:12 2021 Felix Ulrich-PurLow flux test 7.11.218 145.4II(BETA+EFE) 30 spillsGood      none 

Start: 07:20 O(100kHz)

  281   Sun Nov 7 18:59:28 2021 Felix Ulrich-PurLow flux test 7.11.219 62.4II(BETA+EFE) 30 spillsGood      none 

Start: 07:26 O(100kHz)

  295   Sun Nov 7 19:09:50 2021 Felix Ulrich-PurFluence loss meas 7.11.2124 252.7II(BETA+EFE)Proton Good      none 

Start: 13:58

Alignment run without phantom

  296   Sun Nov 7 19:10:31 2021 Felix Ulrich-PurFluence loss meas 7.11.2125 145.4II(BETA+EFE)Proton40e6Good      none 

Start: 14:04

Reference run without phantom

  297   Sun Nov 7 19:11:24 2021 Felix Ulrich-PurFluence loss meas 7.11.2126Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 15:19

1 cm Alu stair phantom on rotary table (0deg--> always 1cm Al in beam)

  298   Sun Nov 7 19:12:57 2021 Felix Ulrich-PurFluence loss meas 7.11.2127Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 16:40

1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu)

  299   Sun Nov 7 19:13:36 2021 Felix Ulrich-PurFluence loss meas 7.11.2128Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 18:00

1 cm Alu stair phantom on rotary table (90deg)

  300   Sun Nov 7 19:28:49 2021 Felix Ulrich-PurFluence loss meas 7.11.2129Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 19:28

1 cm Alu stair phantom on rotary table (0deg)

  301   Sun Nov 7 21:04:43 2021 Felix Ulrich-PurFluence loss meas 7.11.2130 100.4II(BETA+EFE)Proton40e6Good      none 

Start: 21.04

reference run 100.4MeV

  80   Sat Feb 27 09:31:57 2021 Felix Ulrich-PurRate verification6SiC+Si+RaMon252.7I(EFE+SID0)  Good        

Start 07:16
rate looks fine,

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

SiC: man sieht erstmals Signale 

  81   Sat Feb 27 09:40:15 2021 Felix Ulrich-PurRate verification7SiC+Si+RaMon62.4I(EFE+SID0)  Good        

Start 07:40
rate looks fine, however operators mentioned, that CPD data might have been loaded incorrectly-->pause during run and reloaded (07:48), rate seems unchanged

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 
 

  82   Sat Feb 27 09:41:06 2021 Felix Ulrich-PurWaveforms SiC+Si8SiC+Si+RaMon252.7I(EFE+SID0)  Good        

08:34 room request, PC for SiC had to be restarted, trigger were connected as prior to shift

Start 08:53
rate looks fine

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

verändere Position, ab 7:49 bei Aufnahme von Waveforms Position:

x = 0
y = 0

7:51 verändere Position

7:58 neue Position:
x = 8
y = 68

 

FPGA shutdown --> Datenaufzeichnung bis etwa 8:27, ab dann Suchen des Fehlers

 

  83   Sat Feb 27 09:42:44 2021 Felix Ulrich-PurWaveforms SiC+Si9SiC+Si+RaMon145.4I(EFE+SID0)  Good        

Start 09:37

SiC setrup had to be rewired (wr0ng polarity somewhere (insert here))

 

Umstellen:
channel 2: LVDS-Signal vertauschen
channel 2 Referenz: 2.100 V 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  84   Sat Feb 27 18:36:15 2021 Felix Ulrich-PurWaveforms SiC+Si10SiC+Si+RaMon145.4I(EFE+SID0)  Good        

Start 10:10
polarity now correct

Wiederholung von vorher, aber keine Aufnahme von neuen Waveforms

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  85   Sat Feb 27 18:38:09 2021 Felix Ulrich-PurWaveforms SiC+Si11SiC+Si+RaMon62.4I(EFE+SID0)  Good        

Start 10:24
polarity now correct
no signal in sic --> energy too low due to scintis

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  86   Sat Feb 27 18:38:54 2021 Felix Ulrich-PurWaveforms SiC+Si12SiC+Si+RaMon252.7I(EFE+SID0)  Good        

Start 10:28
polarity now correct

now signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  90   Sat Feb 27 18:44:06 2021 Felix Ulrich-PurWaveforms SiC+Si16SiC+Si+RaMon100.4I(EFE+SID0)  Good        

Start 11:36

schöne Signale

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

  117   Tue Mar 2 14:42:56 2021 Patrick SiebererMPW2 Tracking75MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start xx:xx:

Tracker speed test: 2MHz internal Trigger from TLU -> works.

  118   Tue Mar 2 14:45:04 2021 Patrick SiebererMPW2 Tracking76MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start xx:xx:

Tracker speed test: 4MHz internal Trigger from TLU -> works.
Tracker Setting: max_trigger=1 and trigger_busy=25. This gives ~20kHz eventrate.

  119   Tue Mar 2 14:46:49 2021 Patrick SiebererMPW2 Tracking77-82MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start 22:23 (Run79), 22:30, 22:37, 22:43 

Synchronization: Playing around with trgger_busy (range 25-500) This slows down Eventrate, but does not solve our issue of not being able to count all overflows. (This depends on the ratio of events hitting the MPW2 only, NOT on the overall busy rate)