Message ID: 84     Entry time: Sat Feb 27 18:36:15 2021
Author: Felix Ulrich-Pur 
Subject: Waveforms SiC+Si 
Run Number: 10 
DUT: SiC+Si+RaMon 
Beam Energy: 145.4 
Rate Setting: I(EFE+SID0) 
Particle Type:  
Events:  
Data: Good 
Beam Betatron:  
Beam Chopper:  
Beam Degrader:  
Beam EFE:  
Beam Orb:  
Beam QuadScan:  
PhantomType:  
PhantomAngle:  

Start 10:10
polarity now correct

Wiederholung von vorher, aber keine Aufnahme von neuen Waveforms

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68