Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 6 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Thu Oct 7 10:58:19 2021, Philipp Gaggl, Pad Sensoren, 16, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1000 V
Trigger SiC

Entry  Thu Oct 7 10:58:47 2021, Philipp Gaggl, Pad Sensoren, 17, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V
Trigger SiC

Entry  Thu Oct 7 10:59:18 2021, Philipp Gaggl, Pad Sensoren, 18, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

Entry  Thu Oct 7 10:59:57 2021, Philipp Gaggl, Pad Sensoren, 19, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:00:33 2021, Philipp Gaggl, Pad Sensoren, 20, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Thu Oct 7 11:01:19 2021, Philipp Gaggl, Pad Sensoren, 21, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Thu Oct 7 11:01:53 2021, Philipp Gaggl, Pad Sensoren, 22, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:12:10 2021, Philipp Gaggl, Pad Sensoren, 34, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V

Entry  Thu Oct 7 11:12:44 2021, Philipp Gaggl, Pad Sensoren, 35, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Thu Oct 7 11:13:05 2021, Philipp Gaggl, Pad Sensoren, 36, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Thu Oct 7 11:13:21 2021, Philipp Gaggl, Pad Sensoren, 37, SiC+Si, 62.4, , Proton, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Sun Nov 7 18:55:52 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 6, , 62.4, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 07:07 O(MHz)

Entry  Sun Nov 7 18:59:28 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 9, , 62.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:26 O(100kHz)

Entry  Sun Nov 7 19:00:36 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 12, , 62.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:44 O(kHz)

Entry  Sun Nov 21 13:51:53 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 1, SiC+Si, 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the SiC detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:05:18 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 3, , 62.4, I(EFE+SID0), Proton, 10000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sun Nov 21 14:53:00 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 4, Diamond+LGAD, 62.4, I(EFE+SID0), Proton, 100000, , , , , , , , ,  

Bias voltage Diamond: 500

Bias voltage Si LGAD: -100

From a beam perspective the Diamond detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Thu Oct 7 11:07:08 2021, Philipp Gaggl, Pad Sensoren, 28, SiC+Si, 402.8, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Sat Feb 27 19:01:26 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 23, SiC+Si+RaMon, 400.8, nominal, Carbon, , Good, , , 10, , , , ,  

Start 14:18 

14:30 enter room request: abbau and shielding was activated, called RP, removed SiC+Si Setup+Al shielding of DSSDs

Degrader 10, Carbon
Messung bis 14:24

danach neue Aufzeichnung (Hintergrundstrahlung) Start ca 14:25


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

ELOG V3.1.5-fc6679b