Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 7 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Thu Oct 7 11:08:51 2021, Philipp Gaggl, Pad Sensoren, 30, SiC+Si, 306.2, , Carbon, , Unknown, , , 10, , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Sun Jan 10 06:27:26 2021, Maximilian Tomaschek, Lowflux recommissioning, 1, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate,15s spill pause, delay can be set by operator

Entry  Sun Jan 10 06:42:03 2021, Maximilian Tomaschek, Lowflux recommissioning, 8, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 2, ,  

Rate, factor 10 too high, role ~30kHz instead of 3kHz, Beta nominal

Entry  Sun Jan 10 06:45:55 2021, Maximilian Tomaschek, Lowflux recommissioning, 10, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, Beta 10% nominal, now 3kHz

Entry  Sun Jan 10 06:52:24 2021, Maximilian Tomaschek, Lowflux recommissioning, 17, Ramon+Tracker, 252.7, , , 30 spills, , 10%, , 10, 1, , 0, ,  

Rate, now Beta 10%, looks like Beta EFE also ~400kHz

Entry  Sun Jan 10 07:01:04 2021, Maximilian Tomaschek, Lowflux recommissioning, 18, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 0, ,  

Rate, now Beta nominal again, looks like old setting 4-6 Mhz

Entry  Sun Jan 10 07:19:17 2021, Maximilian Tomaschek, Lowflux recommissioning, 28, Ramon+Tracker, 252.7, , , 10 spills 1e6 events, Good, 10%, , 10, 1, , , ,  

Spotsize 

Entry  Sun Jan 10 07:24:46 2021, Maximilian Tomaschek, Lowflux recommissioning, 36, Ramon+Tracker, 252.7, , , 7 spills 1e6 events, Good, , , 10, 1, , 0, ,  

Spotsize

Entry  Sun Jan 10 07:29:09 2021, Maximilian Tomaschek, Lowflux recommissioning, 48, Ramon+Tracker, 252.7, , , 40 spills 250k events, Good, 10%, , 10, 1, , 2, ,  

Spotsize

Entry  Sun Jan 10 07:33:19 2021, Maximilian Tomaschek, Lowflux recommissioning, 55, Peakfinder, 252.7, , , 40 spills 350k events, Good, , , 10, 1, , 0, ,  

fail MAPTA Sensor, not trigger, only signal with 5s spill 5s pause (spill over time meas), looked similar

Entry  Sat Feb 27 09:28:07 2021, Felix Ulrich-Pur, Rate verification, 2, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Crap, , , , , , , ,  

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

Entry  Sat Feb 27 09:29:41 2021, Felix Ulrich-Pur, Rate verification, 4, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Good, , , , , , , ,  

Start 06:55
reallocated correctly, rate looks similar to old measurements now (kHz ish)

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

Entry  Sat Feb 27 09:31:57 2021, Felix Ulrich-Pur, Rate verification, 6, SiC+Si+RaMon, 252.7, I(EFE+SID0), , , Good, , , , , , , ,  

Start 07:16
rate looks fine,

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

SiC: man sieht erstmals Signale 

Entry  Sat Feb 27 09:41:06 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 8, SiC+Si+RaMon, 252.7, I(EFE+SID0), , , Good, , , , , , , ,  

08:34 room request, PC for SiC had to be restarted, trigger were connected as prior to shift

Start 08:53
rate looks fine

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

verändere Position, ab 7:49 bei Aufnahme von Waveforms Position:

x = 0
y = 0

7:51 verändere Position

7:58 neue Position:
x = 8
y = 68

 

FPGA shutdown --> Datenaufzeichnung bis etwa 8:27, ab dann Suchen des Fehlers

 

Entry  Sat Feb 27 18:38:54 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 12, SiC+Si+RaMon, 252.7, I(EFE+SID0), , , Good, , , , , , , ,  

Start 10:28
polarity now correct

now signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Sat Feb 27 18:42:13 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 13, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Good, , , , , , , ,  

Start 10:38
no signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Sat Feb 27 18:50:16 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 19, SiC+Si+RaMon, 252.7, nominal, , , Good, , , 100, , , , ,  

Start 13:40

Degrader 100 
Messung aufgenommen, keine Screenshots

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Sat Feb 27 18:52:12 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 20, SiC+Si+RaMon, 252.7, nominal, Proton, , Good, , , 10, , , , ,  

Start 13:42

Degrader 10


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Sat Feb 27 18:56:11 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 21, SiC+Si+RaMon, 252.7, nominal, Proton, , Good, , , 50, , , , ,  

Start 13:56

Degrader 50


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

 

Entry  Sat Feb 27 18:56:58 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 22, SiC+Si+RaMon, 252.7, nominal, Proton, , Good, , , 100, , , , ,  

Start 14:08

Degrader 100


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

ELOG V3.1.5-fc6679b