Sun Jan 10 06:32:13 2021, Maximilian Tomaschek, Lowflux recommissioning, 2, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , , ,
|
Rate |
Sat Feb 27 09:28:07 2021, Felix Ulrich-Pur, Rate verification, 2, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Crap, , , , , , , ,
|
Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.
NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x: 0
y: 0 |
Tue Mar 16 14:54:07 2021, Patrick Sieberer, Pad Sensoren, 2, , 145.4, III(EFE+SID2), Proton, , Good, , , , , , , none,
|
Start: 06:45
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front |
Wed May 12 08:47:53 2021, Felix Ulrich-Pur, Alignment Run, 2, DSSD-Tracker, 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,
|
TB 24.4.21
Alignment run |
Sun Jun 20 19:30:28 2021, Felix Ulrich-Pur, HADES testrun 100.4MeV, 2, HADES-LGADs, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , none, 0
|
TB 19.6.21
Start 07:51
beam was paused at 10:10
bias run and threshold optimization
mean rate was O(100kHz) |
Sun Nov 7 18:52:10 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 2, , 800, V, , 30 spills, Good, , , , , , , none,
|
Start: 06:40 O(100kHz) |
Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,
|
Bias voltage SiC: 800
Bias voltage Si: -150
From a beam perspective the Si detector was the first target, on oscilloscope channel 1, SiC was the second target connected to oscilloscope channel 3.
Triggering source was the Si detector.
The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.
Data was stored on the HiBPM-Osci-2 NUC under c:\measurements |
Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,
|
Fluence loss measurement 11.12.2021
|
Sat Oct 8 07:20:45 2022, Christian Irmler, testrun ramon + tracker + DUT, 2, RD50-MPW3, 800, , , , Crap, lowflux high, , , , , , ,
|
Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run. |
Sun Jan 10 07:02:15 2021, Maximilian Tomaschek, Lowflux recommissioning, 19, Ramon+Tracker, 194.3, , , 30 spills, Crap, , , 10, 1, , 0, ,
|
Rate, Beta nominal, ERROR tracker -> reset TLU |
Sat Feb 27 18:50:16 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 19, SiC+Si+RaMon, 252.7, nominal, , , Good, , , 100, , , , ,
|
Start 13:40
Degrader 100
Messung aufgenommen, keine Screenshots
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
Tue Mar 16 15:06:13 2021, Patrick Sieberer, Pad Sensoren, 19, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,
|
Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings |
Tue Mar 16 15:17:17 2021, Patrick Sieberer, MPW2 Analog output, 19, MPW2+Picoscope, 800, VII, Proton, , Crap, , , , , , , ,
|
3er Koinzidenz
for Beam |
Thu Oct 7 10:59:57 2021, Philipp Gaggl, Pad Sensoren, 19, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,
|
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V |
Sun Nov 7 19:06:40 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 19, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)
4cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sat Oct 8 10:30:38 2022, Christian Irmler, ramon + tracker + DUT, 19, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,
|
ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check |
Sun Jan 10 07:01:04 2021, Maximilian Tomaschek, Lowflux recommissioning, 18, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 0, ,
|
Rate, now Beta nominal again, looks like old setting 4-6 Mhz |
Sat Feb 27 18:49:06 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 18, SiC+Si+RaMon, 800, VII, , , Good, , , , , , , ,
|
Start 12:39
Neustart der vorherigen Messung
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
Tue Mar 16 15:05:40 2021, Patrick Sieberer, Pad Sensoren, 18, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,
|
Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15 |
Tue Mar 16 15:16:58 2021, Patrick Sieberer, MPW2 Analog output, 18, MPW2+Picoscope, 800, VII, Proton, , Crap, , , , , , , ,
|
2er Koinzidenz
Pix 06, 33, 34
for Beam |
|