  MedAustron 2021, Page 13 of 18  Not logged in ELOG logo
Entry  Sun Jan 10 06:32:13 2021, Maximilian Tomaschek, Lowflux recommissioning, 2, Ramon+Tracker, 194.3, , , 30 spills, , 10%, , 10, 1, , , ,  

Rate

Entry  Sat Feb 27 09:28:07 2021, Felix Ulrich-Pur, Rate verification, 2, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Crap, , , , , , , ,  

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

Entry  Tue Mar 16 14:54:07 2021, Patrick Sieberer, Pad Sensoren, 2, , 145.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  

Start: 06:45
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

Entry  Wed May 12 08:47:53 2021, Felix Ulrich-Pur, Alignment Run, 2, DSSD-Tracker, 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

TB 24.4.21
Alignment run

Entry  Sun Jun 20 19:30:28 2021, Felix Ulrich-Pur, HADES testrun 100.4MeV, 2, HADES-LGADs, 100.4, II(BETA+EFE), Proton, , Good, , , , , , , none, 0 

TB 19.6.21

Start 07:51
beam was paused at 10:10

bias run and threshold optimization

mean rate was O(100kHz)

Entry  Sun Nov 7 18:52:10 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 2, , 800, V, , 30 spills, Good, , , , , , , none,  

Start: 06:40 O(100kHz)

Entry  Sun Nov 21 13:55:05 2021, Simon Waid, Comparison SiC, Si, Si LGAD and Diamond, 2, SiC+Si, 62.4, I(EFE+SID0), Proton, 1000000, , , , , , , , ,  

Bias voltage SiC: 800

Bias voltage Si: -150

From a beam perspective the Si detector was the first target, on oscilloscope  channel 1, SiC was the second target connected to oscilloscope channel 3.

Triggering source was the Si detector.

The compliancy of the SiC SMU triggered after approx. 50% of the events had been acquired after this event the HV for the SiC HV was shut down.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

Entry  Sat Dec 11 17:47:45 2021, Felix Ulrich-Pur, Alignment run, 2, DSSD-Tracker, 800, V, Proton, , Good, , , , , , , none,  

Fluence loss measurement 11.12.2021

 

 

Entry  Sat Oct 8 07:20:45 2022, Christian Irmler, testrun ramon + tracker + DUT, 2, RD50-MPW3, 800, , , , Crap, lowflux high, , , , , , ,  

Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run.

Entry  Sun Jan 10 07:02:15 2021, Maximilian Tomaschek, Lowflux recommissioning, 19, Ramon+Tracker, 194.3, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, ERROR tracker  -> reset TLU

Entry  Sat Feb 27 18:50:16 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 19, SiC+Si+RaMon, 252.7, nominal, , , Good, , , 100, , , , ,  

Start 13:40

Degrader 100 
Messung aufgenommen, keine Screenshots

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:06:13 2021, Patrick Sieberer, Pad Sensoren, 19, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings

Entry  Tue Mar 16 15:17:17 2021, Patrick Sieberer, MPW2 Analog output, 19, MPW2+Picoscope, 800, VII, Proton, , Crap, , , , , , , ,  

3er Koinzidenz
for Beam

Entry  Thu Oct 7 10:59:57 2021, Philipp Gaggl, Pad Sensoren, 19, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Sun Nov 7 19:06:40 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 19, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sat Oct 8 10:30:38 2022, Christian Irmler, ramon + tracker + DUT, 19, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,  

ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check

Entry  Sun Jan 10 07:01:04 2021, Maximilian Tomaschek, Lowflux recommissioning, 18, Ramon+Tracker, 252.7, , , 30 spills, , , , 10, 1, , 0, ,  

Rate, now Beta nominal again, looks like old setting 4-6 Mhz

Entry  Sat Feb 27 18:49:06 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 18, SiC+Si+RaMon, 800, VII, , , Good, , , , , , , ,  

Start 12:39

Neustart der vorherigen Messung

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:05:40 2021, Patrick Sieberer, Pad Sensoren, 18, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15

Entry  Tue Mar 16 15:16:58 2021, Patrick Sieberer, MPW2 Analog output, 18, MPW2+Picoscope, 800, VII, Proton, , Crap, , , , , , , ,  

2er Koinzidenz
Pix 06, 33, 34
for Beam