Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 12 of 18  Not logged in ELOG logo
Entry  Tue Mar 16 15:09:04 2021, Patrick Sieberer, Pad Sensoren, 22, , 800, V, Proton, , Good, , , , , , , none,  

Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA

Entry  Tue Mar 16 15:18:31 2021, Patrick Sieberer, MPW2 Analog output, 22, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

3er Koinzidenz
for Beam

Entry  Thu Oct 7 11:01:53 2021, Philipp Gaggl, Pad Sensoren, 22, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V

Entry  Sun Nov 7 19:08:47 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 22, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement

Entry  Sat Oct 8 10:37:45 2022, Christian Irmler, ramon + tracker + DUT, 22, RD50-MPW3, 252.7, , , , Unknown, lowflux low, , , , , , ,  

ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at a low frequency.

Will use this threshold from now on.

 

 

Entry  Sun Jan 10 07:04:21 2021, Maximilian Tomaschek, Lowflux recommissioning, 21, Ramon+Tracker, 145.4, , , 15 spills, Good, , , 10, 1, , 0, ,  

Rate, Beta nominal

Entry  Sat Feb 27 18:56:11 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 21, SiC+Si+RaMon, 252.7, nominal, Proton, , Good, , , 50, , , , ,  

Start 13:56

Degrader 50


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

 

Entry  Tue Mar 16 15:07:56 2021, Patrick Sieberer, Pad Sensoren, 21, , 100.4, III(EFE+SID2), Proton, , Good, , , , , , , none,  

Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated

Entry  Tue Mar 16 15:18:23 2021, Patrick Sieberer, MPW2 Analog output, 21, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

3er Koinzidenz
for Beam

Entry  Thu Oct 7 11:01:19 2021, Philipp Gaggl, Pad Sensoren, 21, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V

Entry  Sun Nov 7 19:07:31 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 21, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

Entry  Sat Oct 8 10:35:23 2022, Christian Irmler, ramon + tracker + DUT, 21, RD50-MPW3, 252.7, , , , Crap, lowflux low, , , , , , ,  

ASIC: TH 1350
BEAM OFF, for TH check

no noise hits

 

Entry  Sun Jan 10 07:03:56 2021, Maximilian Tomaschek, Lowflux recommissioning, 20, Ramon+Tracker, 175.3, , , 30 spills, Good, , , 10, 1, , 0, ,  

Rate, Beta nominal

Entry  Sat Feb 27 18:52:12 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 20, SiC+Si+RaMon, 252.7, nominal, Proton, , Good, , , 10, , , , ,  

Start 13:42

Degrader 10


channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:07:06 2021, Patrick Sieberer, Pad Sensoren, 20, , 100.4, I(EFE+SID0), Proton, , Good, , , , , , , none,  

Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA

Entry  Tue Mar 16 15:17:58 2021, Patrick Sieberer, MPW2 Analog output, 20, MPW2+Picoscope, 800, VII, Proton, , Crap, , , , , , , ,  

3er Koinzidenz
for Beam

Entry  Tue Mar 16 15:18:12 2021, Patrick Sieberer, MPW2 Analog output, 20, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

3er Koinzidenz
for Beam

Entry  Thu Oct 7 11:00:33 2021, Philipp Gaggl, Pad Sensoren, 20, SiC+Si, 62.4, I(EFE+SID0), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

Entry  Sun Nov 7 19:06:58 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 20, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sat Oct 8 10:32:44 2022, Christian Irmler, ramon + tracker + DUT, 20, RD50-MPW3, 252.7, , , , Crap, lowflux low, , , , , , ,  

ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected --> invalid

ELOG V3.1.5-fc6679b