Entry is currently edited by Felix Ulrich-Pur on 80.120.130.63    294   Sun Dec 6 20:04:27 2020 Christian IrmlerMPW2213W13_04252.71  1   HV = 80V10 spills 

pixel scan, starting with r0 c7

 

  293   Sun Dec 6 19:51:49 2020 Christian IrmlerMPW2212W13_04252.71  1   HV = 80V10 spillsCrap

pixel scan, starting with r0 c7

stopped due to broken pipe

Caribou rebooted

  292   Sun Dec 6 19:30:38 2020 Christian IrmlerMPW2211W13_04252.71  1   HV = 80V10 spills 

pixle scan, starting with r0 c0

stopped after r0 c6 due network error (oscilloscope connected)

beam rate ~400k

hit rate MPW2: ~400 hits per spill

  291   Sun Dec 6 19:29:57 2020 Christian IrmlerMPW2210W13_04252.71  1   HV = 80V10 spills 

single pixel r0 c2

test run for new beam settings

  23   Sun May 10 20:41:43 2020 Felix Ulrich-PurBeam+Diamond 500V21Diamond194.3nonenone EFE SID2none 150960 

Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

  46   Sat Jun 13 04:04:16 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 30021TERA-Cal100.4BETA  EFE  none 200000 

Linearity Messung Gain 300 10e5 rate

  131   Sat Jul 4 04:44:19 2020 Felix Ulrich-PurEFE SID2 spot-size measurement21Lynx+RaMon+Octavius+Film62.4   yes SID2    

tested 180s exposure time of Lynx, no signal in Lynx or Octavius

35min irradiation of film (no signal)

  175   Sat Oct 10 12:58:48 2020 Manuel Christanell2020-10-1021TERA+Tracker           

without Beam; Tracker no trigger; Rotation table problems

  290   Sun Dec 6 19:07:20 2020 Christian IrmlerMPW2209W13_04252.7   1 SID0 HV = 80V10 spills 

single pixel r0 c2

shutter time set to 6s 

  289   Sun Dec 6 18:59:48 2020 Christian IrmlerMPW2208W13_04252.7   1 SID0 HV = 80V10 spills 

single pixel r0 c2

shutter time set to 2.5s (half of previous value)

  288   Sun Dec 6 16:53:35 2020 Christian IrmlerMPW2207W13_04252.7   1 SID0 HV = 80V10 spills 

pixel scan, starting with r3 c3

tried to syncronized clocks of Caribou and TLU syncronized before run started.
clock of caribou is still 3s ahead. --> need to use ntp server next time.

was interrupted between spill 64 an 65 for about 40 minutes due to MAPTA error (HL-tank error)

stopped after r7 c7

  287   Sun Dec 6 16:32:54 2020 Christian IrmlerMPW2206W13_04252.7   1 SID0 HV = 80V10 spills 

pixel scan, starting with r1 c6

stopped after r3 c2

stopped due to time difference of ~10s between TLU and Caribou

  286   Sun Dec 6 16:01:02 2020 Christian IrmlerMPW2205W13_04252.7   1 SID0 HV = 80V10 spills 

pixel scan, starting with r0 c0

stopped after r1 c5 due to synch issues

  285   Sun Dec 6 15:57:28 2020 Christian IrmlerMPW2204W13_04252.7   1 SID0 HV = 20V10 spills 

r0 c2

  284   Sun Dec 6 15:55:13 2020 Christian IrmlerMPW2203W13_04252.7   1 SID0 HV = 1V10 spills 

r0 c2

lowest Voltage, which could be set with SMU outputs on.

  283   Sun Dec 6 15:53:12 2020 Christian IrmlerMPW2202W13_04252.7   1 SID0 HV off10 spills 

r0 c2

HV set to 0V, but KeithRC SW turned SMU output off 

  282   Sun Dec 6 15:45:45 2020 Christian IrmlerMPW2201W13_04252.7   1 SID0 HV = 100V10 spills 

r0 c2

  281   Sun Dec 6 15:44:51 2020 Christian IrmlerMPW2200W13_04252.7   1 SID0 HV = during ramping10 spillsCrap

HV = 

r0 c2

  22   Sun May 10 20:26:25 2020 Felix Ulrich-PurBeam+Diamond 500V20Diamond100.4nonenone EFE SID2none 103032 

Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

  45   Sat Jun 13 04:03:29 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 20020TERA-Cal100.4BETA  EFE  none 200000 

Linearity Messung Gain 200 10e5 rate