Entry is currently edited by Felix Ulrich-Pur on 80.120.130.63  Entry  Sun Dec 6 20:04:27 2020, Christian Irmler, MPW2, 213, W13_04, 252.7, 1, , , 1, , , , HV = 80V, 10 spills,  

pixel scan, starting with r0 c7

 

Entry  Sun Dec 6 19:51:49 2020, Christian Irmler, MPW2, 212, W13_04, 252.7, 1, , , 1, , , , HV = 80V, 10 spills, Crap 

pixel scan, starting with r0 c7

stopped due to broken pipe

Caribou rebooted

Entry  Sun Dec 6 19:30:38 2020, Christian Irmler, MPW2, 211, W13_04, 252.7, 1, , , 1, , , , HV = 80V, 10 spills,  

pixle scan, starting with r0 c0

stopped after r0 c6 due network error (oscilloscope connected)

beam rate ~400k

hit rate MPW2: ~400 hits per spill

Entry  Sun Dec 6 19:29:57 2020, Christian Irmler, MPW2, 210, W13_04, 252.7, 1, , , 1, , , , HV = 80V, 10 spills,  

single pixel r0 c2

test run for new beam settings

Entry  Sun May 10 20:41:43 2020, Felix Ulrich-Pur, Beam+Diamond 500V, 21, Diamond, 194.3, none, none, , EFE, , SID2, none, , 150960,  

Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

Entry  Sat Jun 13 04:04:16 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 300, 21, TERA-Cal, 100.4, BETA, , , EFE, , , none, , 200000,  

Linearity Messung Gain 300 10e5 rate

Entry  Sat Jul 4 04:44:19 2020, Felix Ulrich-Pur, EFE SID2 spot-size measurement, 21, Lynx+RaMon+Octavius+Film, 62.4, , , , yes, , SID2, , , ,  

tested 180s exposure time of Lynx, no signal in Lynx or Octavius

35min irradiation of film (no signal)

Entry  Sat Oct 10 12:58:48 2020, Manuel Christanell, 2020-10-10, 21, TERA+Tracker, , , , , , , , , , ,  

without Beam; Tracker no trigger; Rotation table problems

Entry  Sun Dec 6 19:07:20 2020, Christian Irmler, MPW2, 209, W13_04, 252.7, , , , 1, , SID0, , HV = 80V, 10 spills,  

single pixel r0 c2

shutter time set to 6s 

Entry  Sun Dec 6 18:59:48 2020, Christian Irmler, MPW2, 208, W13_04, 252.7, , , , 1, , SID0, , HV = 80V, 10 spills,  

single pixel r0 c2

shutter time set to 2.5s (half of previous value)

Entry  Sun Dec 6 16:53:35 2020, Christian Irmler, MPW2, 207, W13_04, 252.7, , , , 1, , SID0, , HV = 80V, 10 spills,  

pixel scan, starting with r3 c3

tried to syncronized clocks of Caribou and TLU syncronized before run started.
clock of caribou is still 3s ahead. --> need to use ntp server next time.

was interrupted between spill 64 an 65 for about 40 minutes due to MAPTA error (HL-tank error)

stopped after r7 c7

Entry  Sun Dec 6 16:32:54 2020, Christian Irmler, MPW2, 206, W13_04, 252.7, , , , 1, , SID0, , HV = 80V, 10 spills,  

pixel scan, starting with r1 c6

stopped after r3 c2

stopped due to time difference of ~10s between TLU and Caribou

Entry  Sun Dec 6 16:01:02 2020, Christian Irmler, MPW2, 205, W13_04, 252.7, , , , 1, , SID0, , HV = 80V, 10 spills,  

pixel scan, starting with r0 c0

stopped after r1 c5 due to synch issues

Entry  Sun Dec 6 15:57:28 2020, Christian Irmler, MPW2, 204, W13_04, 252.7, , , , 1, , SID0, , HV = 20V, 10 spills,  

r0 c2

Entry  Sun Dec 6 15:55:13 2020, Christian Irmler, MPW2, 203, W13_04, 252.7, , , , 1, , SID0, , HV = 1V, 10 spills,  

r0 c2

lowest Voltage, which could be set with SMU outputs on.

Entry  Sun Dec 6 15:53:12 2020, Christian Irmler, MPW2, 202, W13_04, 252.7, , , , 1, , SID0, , HV off, 10 spills,  

r0 c2

HV set to 0V, but KeithRC SW turned SMU output off 

Entry  Sun Dec 6 15:45:45 2020, Christian Irmler, MPW2, 201, W13_04, 252.7, , , , 1, , SID0, , HV = 100V, 10 spills,  

r0 c2

Entry  Sun Dec 6 15:44:51 2020, Christian Irmler, MPW2, 200, W13_04, 252.7, , , , 1, , SID0, , HV = during ramping, 10 spills, Crap 

HV = 

r0 c2

Entry  Sun May 10 20:26:25 2020, Felix Ulrich-Pur, Beam+Diamond 500V, 20, Diamond, 100.4, none, none, , EFE, , SID2, none, , 103032,  

Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

Entry  Sat Jun 13 04:03:29 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 200, 20, TERA-Cal, 100.4, BETA, , , EFE, , , none, , 200000,  

Linearity Messung Gain 200 10e5 rate