Tue Jan 7 16:36:49 2014, Markus Friedl, Infineon, run, run024, 200k, 07.01.2014 16:35:44, 07.01.2014 17:03:10, Good
|
HV=210V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:54:22 2014, Markus Friedl, Infineon, run, run023, 200k, 07.01.2014 15:53:06, 07.01.2014 16:25:26, Good
|
HV=200V I=8.0uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:16:11 2014, Markus Friedl, Infineon, run, run022, 200k, 07.01.2014 15:15:09, 07.01.2014 15:42:17, Good
|
HV=150V I=7.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 14:47:38 2014, Markus Friedl, Infineon, run, run021, 200k, 07.01.2014 14:46:08, 07.01.2014 15:13:23, Good
|
HV=100V I=7.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 13:20:48 2014, Markus Friedl, Infineon, run, run020, 300k, 07.01.2014 13:18:52, 07.01.2014 14:35:49, Good
|
HV=300V I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
multi6 with same settings as run019 (htr+3)
Beam energy = 3 GeV |
Tue Jan 7 11:52:27 2014, Markus Friedl, Infineon, run, run019, 650k, 07.01.2014 11:47:24, 07.01.2014 13:15:21, Good
|
HV=300V I=9.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single sample run
Beam energy = 3 GeV |
Tue Jan 7 09:33:16 2014, Thomas Bergauer, , run, run017, 100k, 07.01.2014 09:31:45, 07.01.2014 09:52:58, Good
|
HV=300V I=9.08uA
position adapted to center beam better (+10mm horizonal)
DESY table z=-346 x=-255
3Gev/c |
Tue Jan 7 09:22:09 2014, Thomas Bergauer, , run, run016, 50k, 07.01.2014 09:19:10, 07.01.2014 09:30:03, Good
|
HV=290V I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)
DESY table z=-346 x=-255 |
Tue Jan 7 09:12:24 2014, Thomas Bergauer, Belle SVD, run, run015, 20k, 07.01.2014 09:10:52, 07.01.2014 09:15:39, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
energy switched back to 3Gev/c |
Tue Jan 7 08:36:29 2014, Thomas Bergauer, Infineon, run, run014, 20k, 07.01.2014 08:34:06, 07.01.2014 09:05:47, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6Gev/c,
bad strip region hardly hit |
Tue Jan 7 02:18:26 2014, Markus Friedl, Infineon, run, run013, 215k, 07.01.2014 02:14:50, 07.01.2014 08:31:25, Crap
|
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum
close to end: switched to 6GeV
bias voltage accidentally left at 150V instead of initially planned 290V |
Tue Jan 7 00:36:03 2014, Markus Friedl, Infineon, run, run012, 190k, 07.01.2014 00:33:58, 07.01.2014 02:12:32 , Good
|
HV=150V I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum
close to end: switched to 6GeV |
Mon Jan 6 23:50:59 2014, Markus Friedl, Infineon, run, run011, 200k, 06.01.2014 23:49:09, 07.01.2014 00:30:38 , Good
|
HV=280V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 23:06:51 2014, Markus Friedl, Infineon, run, run010, 200k, 06.01.2014 23:03:23, 06.01.2014 23:47:02 , Good
|
HV=270V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 22:23:39 2014, Markus Friedl, Infineon, run, run009, 200k, 06.01.2014 22:22:10, 06.01.2014 23:03:23, Good
|
HV=260V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 21:40:29 2014, Markus Friedl, Infineon, run, run008, 200k, 06.01.2014 21:38:46, 06.01.2014 22:20:13, Good
|
HV=210V I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 20:57:38 2014, Markus Friedl, Infineon, run, run007, 200k, 06.01.2014 20:56:08, 06.01.2014 21:36:54, Good
|
HV=220V I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 20:14:21 2014, Markus Friedl, Infineon, run, run006, 200k, 06.01.2014 20:12:20, 06.01.2014 20:54:34, Good
|
HV=240V I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 19:31:44 2014, Markus Friedl, AIDA, run, run005, 200k, 06.01.2014 19:29:52, 06.01.2014 20:09:59, Good
|
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
Mon Jan 6 18:49:00 2014, Markus Friedl, Infineon, run, run004, 200k, 06.01.2014 18:47:38, 06.01.2014 19:27:33, Good
|
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
|