Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 4 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Project --
common
Belle SVD
Infineon
AIDA
-- Data --
Unknown
Good
Crap
97 Entries
Goto page
Previous
1
,
2
,
3
, 4,
5
Next
All
ID
Date
Author
Project
Subject
Run Number
Events
StartTime
EndTime
Data
Text
17
Tue Jan 7 02:17:14 2014
Thomas Bergauer
beam momentum 6GeV/c
run013
Unknown
19
Tue Jan 7 08:36:29 2014
Thomas Bergauer
Infineon
run
run014
20k
07.01.2014 08:34:06
07.01.2014 09:05:47
Good
HV=290V I=9.55uA
position
centered horizontally (+5mm)
DESY
table z=-346 x=-255
20
Tue Jan 7 09:12:24 2014
Thomas Bergauer
Belle SVD
run
run015
20k
07.01.2014 09:10:52
07.01.2014 09:15:39
Good
HV=290V I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255
energy
21
Tue Jan 7 09:22:09 2014
Thomas Bergauer
run
run016
50k
07.01.2014 09:19:10
07.01.2014 09:30:03
Good
HV=290V I=9.00uA
position
move back to original position (0mm/0mm)
(not hitting the right APVs anymore)
DESY
22
Tue Jan 7 09:33:16 2014
Thomas Bergauer
run
run017
100k
07.01.2014 09:31:45
07.01.2014 09:52:58
Good
HV=300V I=9.08uA
position
adapted to center beam better (+10mm horizonal)
DESY
table z=-346 x=-255
23
Tue Jan 7 09:33:51 2014
Thomas Bergauer
common
beam momentum back to 3Gev/c
run014 and later ones
Unknown
28
Tue Jan 7 14:51:45 2014
Thomas Bergauer
Belle SVD
TLU control
Unknown
1. ssh bastion
2. ssh belle-control
3. ssh
41
Wed Jan 8 12:40:30 2014
Thomas Bergauer
AIDA
intcal AIDA Stack
cal034
83.8k
08.01.2014 12:32:22
08.01.2014 13:01:30
Unknown
HV=100V I=4.5uA
position adapted to center beam
42
Wed Jan 8 14:10:07 2014
Thomas Bergauer
AIDA
run
run035
211681
08.01.2014 14:01:25
08.01.2014 17:03:55
Unknown
HV=100V I=4.2uA
position adapted to center beam
accidentally
hit reset button on PC which ended this run
50
Thu Jan 9 14:47:21 2014
Thomas Bergauer
common
position of DESY Table
Unknown
BEAM mode:
height (z): -346 (initially:
-357)
horizontal (x): -255
OFF
71
Fri Jan 24 11:03:14 2014
Wolfgang Treberspurg
AIDA
AIDA
HW_AIDA002
0
24.01.2014 10:02
Crap
TuxDaq crashed
73
Fri Jan 24 18:02:46 2014
Wolfgang Treberspurg
Infineon
New Infineon Stack
Good
Exchanged AIDA stack with modified Infineon
Stack
Configuration:
74
Sat Jan 25 18:24:03 2014
Wolfgang Treberspurg
Infineon
Single mode Run Stack 2
HW_Run_Infineon_Stack2_001
1.05 M
25.01.2014 10:30
25.01.2014 15:40
Unknown
HV at 300V; I at app. 11µA 4GeV,
Single mode
Modules centered to beam but no hits
75
Sat Jan 25 18:28:38 2014
Wolfgang Treberspurg
Infineon
Calibration run Infineon Stack 2
Calibration_Run_Infineon_Stack2_001
82900
25.01.2014 10:15
25.01.2014 10:25
Unknown
HV 300V, I ca. 11µA single mode
76
Sat Jan 25 18:46:32 2014
Wolfgang Treberspurg
Infineon
Mulit 6 mode Run Stack 2
HW_Run_Infineon_Stack2_Multi_001
340k
25.01.2014 16:30
25.01.2014 18:40
Unknown
HV 300V, I 10µA
Beam Energy changed during the run
between 2GeV - 5GeV - 4GeV
77
Sat Jan 25 21:14:46 2014
Wolfgang Treberspurg
Infineon
Mulit 6 mode Run Stack 2
HW_Run_Infineon_Stack2_Multi_002
230k
25.01.2014 19:00
25.01.2014 21:15
Good
HV 300V, I 10µA
Beam Energy 4GeV
Latency changed to 93
78
Sun Jan 26 19:12:42 2014
Wolfgang Treberspurg
Infineon
Single mode Run Stack 2
HW_Run_Infineon_Stack2_002
4 M
25.01.2014 22:30
26.01.2014 15:15
Good
HV at 300V; I at app. 11µA 4GeV,
Single mode
79
Sun Jan 26 19:14:07 2014
Wolfgang Treberspurg
Infineon
Single mode Run Stack 2
HW_Run_Infineon_Stack2_003
140 k
26.01.2014 18:10
26.01.2014 19:15
Good
HV at 300V; I at app. 10µA 5GeV,
Single mode
80
Mon Jan 27 12:20:53 2014
Wolfgang Treberspurg
Infineon
Single mode Run Stack 2
HW_Run_Infineon_Stack2_004
800k
27.01.2014 09:10
27.01.2014 12:15
Good
HV at 300V; I at app. 10µA 3GeV,
Single mode
81
Wed Jan 29 12:02:52 2014
Wolfgang Treberspurg
Infineon
Single mode Run Stack 2 Bias Scan
HW_Run_Infineon_Stack2_BiasScan_001
100k
28.01.2014 16:30
28.01.2014 16:50
Good
HV at 0V; I at app. 5nA 3GeV, Single mode
Goto page
Previous
1
,
2
,
3
, 4,
5
Next
All
ELOG V3.1.5-fc6679b