Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 6 of 7  Not logged in ELOG logo
Entry  Fri Oct 20 15:26:26 2017, Peter Paulitsch, IFX_200_3e14, run000201, 201, 100000, 75.93, 65.30, -90.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000201.dat
Telescope filename  run000201.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced no
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.7%

 

Entry  Fri Oct 20 15:27:28 2017, Peter Paulitsch, IFX_200_3e14, run000204, 204, 1000000, 75.93, 65.30, -90.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000204.dat
Telescope filename  run000204.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1000000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

Entry  Fri Oct 20 15:30:18 2017, Peter Paulitsch, IFX_200_3e14, run000206, 206, 1010000, 75.93, 65.30, -90.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000206.dat
Telescope filename  run000206.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Fri Oct 20 15:32:27 2017, Peter Paulitsch, IFX_200_3e14, run000208, 208, 110000, 75.93, 65.30, -80.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000208.dat
Telescope filename  run000208.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Fri Oct 20 15:33:44 2017, Peter Paulitsch, IFX_200_3e14, run000210, 210, 1010000, 75.93, 65.30, -80.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000210.dat
Telescope filename  run000210.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.9%

 

Entry  Fri Oct 20 15:35:24 2017, Peter Paulitsch, IFX_200_3e14, run000212, 212, 510000, 75.93, 65.30, -80.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000212.dat
Telescope filename  run000212.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 510000
Telescope triggers 500000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.3%

 

Entry  Fri Oct 20 15:37:26 2017, Peter Paulitsch, IFX_200_3e14, run000217, 217, 110000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000217.dat
Telescope filename  run000217.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

Entry  Fri Oct 20 15:41:56 2017, Peter Paulitsch, IFX_200_3e14, run000219, 219, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000219.dat
Telescope filename  run000219.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

Entry  Fri Oct 20 15:48:34 2017, Peter Paulitsch, IFX_200_3e14, run000220, 220, 300000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000220.dat
Telescope filename  run000220.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -800 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 300000
Telescope triggers 300000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.4%

 

Entry  Sat Oct 21 09:57:58 2017, Peter Paulitsch, IFX_200_3e14, run000221, 221, 250000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000221.dat
Telescope filename  run000221.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -800 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 250000
Telescope triggers 250000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.4%

 

Entry  Sat Oct 21 10:04:21 2017, Peter Paulitsch, IFX_200_3e14, run000222, 222, 250000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000222.dat
Telescope filename  run000222.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -800 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 250000
Telescope triggers 250000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.4%

 

Entry  Sat Oct 21 10:12:42 2017, Peter Paulitsch, IFX_200_3e14, run000223, 223, 300000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000223.dat
Telescope filename  run000223.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -800 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 300000
Telescope triggers 300000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 32.3%

 

Entry  Sat Oct 21 10:14:07 2017, Peter Paulitsch, IFX_200_3e14, run000225, 225, 1000000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000225.dat
Telescope filename  run000225.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 32.3%

 

Entry  Mon Oct 23 12:07:01 2017, Peter Paulitsch, IFX_200_3e14, run000172, 169, crashed, 6000000, bad header, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000172.dat
Telescope filename  run000172.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 6000000
Telescope triggers 6000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

Entry  Mon Oct 23 12:10:15 2017, Peter Paulitsch, IFX_200_3e14, run000175, 175, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000177.dat
Telescope filename  run000177.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Mon Oct 23 12:19:57 2017, Peter Paulitsch, IFX_200_3e14, run000186, 188, 100000, 75.93, 65.30, -100.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000186.dat
Telescope filename  run000186.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Tue Oct 17 14:46:26 2017, Dominic Bloech, IFX_CenterBias, run000080, 80, 500000, 122.9, 26, -3.3°, No, Unknown 

 

run settings
Parameter Value
Alibava filename  run000080.dat
Telescope filename  run000080.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 500000
Telescope triggers  
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 43,6%

 

Entry  Tue Oct 17 15:13:42 2017, Dominic Bloech, IFX_CenterBias, run000081, 81, 1010000, 122.9, 26, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000081.dat
Telescope filename  run000081.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

Entry  Tue Oct 17 15:15:32 2017, Dominic Bloech, IFX_CenterBias, run000083 , 83, 260000, 122.9, 26, -3.3°, No, Unknown 
run settings
Parameter Value
Alibava filename  run000083.dat
Telescope filename  run000083.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 260000
Telescope triggers  
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44,2%

 

Entry  Wed Oct 18 11:48:51 2017, Peter Paulitsch, IFX_CenterBias, run000085, 85, 1010000, 122.9, 26, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000085.dat
Telescope filename  run000085.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

ELOG V3.1.5-fc6679b