Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
|
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
|
Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter) |
Not logged in |
 |
|
Message ID: 51
Entry time: Sat Oct 21 10:12:42 2017
|
Author: |
Peter Paulitsch |
DUT: |
IFX_200_3e14 |
Subject: |
run000223 |
Run Number: |
223 |
Events: |
300000 |
XYPosition: |
75.93, 65.30, -70.55° |
Cooling: |
Yes |
Data: |
Good |
|
|
run settings
Parameter |
Value |
Alibava filename |
run000223.dat |
Telescope filename |
run000223.raw |
Pedestal filename |
KIT_pedestal_600V_20102017.ped |
Bias voltage |
-800 V |
Dark current |
|
Sensor temperature |
-6 |
Latency |
140 [a.u.] |
Alibava triggers |
300000 |
Telescope triggers |
300000 |
Data synced |
yes |
Table position x/y |
75.93, 65.30 |
Region of interest |
bias line |
Trigger frequency |
|
Meas. time |
|
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
32.3% |
|